Page  64   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 5.7.6.1   Norway and Sweden  
To the end of the subclause the following is added:  
The screen of the television distribution system is 
normally not earthed at the entrance of t he building and 
there is normally no equipotential bonding system within 
the building. Therefore the protective earthing of the 
building installation needs to be isolated from the screen 
of a cable distribution system.  
It is however accepted to provide the   insulation external 
to the equipment by an adapter or an interconnection 
cable with galvanic isolator, which may be provided by a 
retailer, for example.  
The user manual shall then have the following or similar 
information in Norwegian and Swedish language  
respectively, depending on in what country the 
equipment is intended to be used in:  
“Apparatus connected to the protective earthing of the 
building installation through the mains connection or 
through other apparatus with a connection to protective 
earthi ng  –   and to a television distribution system using 
coaxial cable, may in some circumstances create a fire 
hazard. Connection to a television distribution system 
therefore has to be provided through a device providing 
electrical isolation below a certain fr equency range 
(galvanic isolator, see EN 60728 - 11)”  
NOTE In Norway, due to regulation for CATV - installations, and in 
Sweden, a galvanic isolator shall provide electrical insulation below 5 
MHz. The insulation shall withstand a dielectric strength of 1,5 kV  
r.m.s., 50 Hz or 60 Hz, for 1 min.  
 
Translation to Norwegian (the Swedish text will also be 
accepted in Norway):  
“Apparater som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet utstyr  –   og er 
tilkoplet et koaksialbasert kabel - TV nett, kan forårsake  
brannfare. For å  unngå dette skal det ved tilkopling av 
apparater til kabel - TV nett installeres en galvanisk 
isolator mellom apparatet og kabel - TV nettet.”  
Translation to Swedish:  
”Apparater som är kopplad till skyddsjord via jordat  
vä gguttag och/eller via annan utrustning och samtidigt 
är kopplad till kabel - TV nät kan i viss a fall medfőra risk 
főr brand. Főr att undvika detta skall vid anslutning av 
apparaten till kabel - TV nät galvanisk isolator finnas 
mellan apparaten och kabel - TV nätet.”.     N/A   

   
 
Page  68   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  ATTACHMENT TO TEST R EPORT  
IEC 62368 - 1  
EUROPEAN GROUP DIFFE RENCES AND NATIONAL  DIFFERENCES  
(AUDIO/VIDEO, INFORM ATION AND COMMUNICAT ION TECHNOLOGY EQUIP MENT  -   PART 1: SAFET Y 
REQUIREMENTS)  
Differences  according to   ...............   :  
EN  IEC 62368 - 1:2020+A11:2020  
Attachment Form No . .....................   :  
EU_GD_IEC62368_1C  
Attachment Originator   ...................   :  
UL(Demko)  
Master Attachment   .........................   :  
2020 - 03 - 10  
Copyright ©  2020 IEC System for Conformity Testing and Certification of Electrical Equipment 
(IECEE), Geneva, Switzerland . All rights reserved.  
  CENELEC COMMON MODIFICATIONS (EN)  
P  
  Clause numbers in the cells that are shaded light grey are clause references in EN 
IEC 62368 - 1:2020+A11:2020. All other clause numbers in that column, except for 
those in the paragraph below, r efers to IEC 62368 - 1:2018.  
 
Clauses, subclauses, notes, tables, figures and annexes which are additional to 
those in IEC 62368 - 1:2018 are prefixed “Z”.   P  
  Add the following annexes:  
Annex ZA (normative)     Normative references to international publications   
      with their corresponding European publications  
Annex ZB (normative)     Special national conditions  
Annex ZC (informative)     A - deviations  
Annex ZD (informative)     IEC and CENELEC code designations for flexible   
        cords   P  
1   Modification to Clause 3 .  
N/A  
3.3.19   Sound exposure  
Replace 3.3.19 of IEC 62368 - 1 with the following definitions:   N/A  
3.3.19.1  
  momentary exposure level, MEL  
metric for estimating 1 s sound exposure level from 
the HD 483 - 1 S2 test signal applied to both channels, 
based on EN 50332 - 1: 2013, 4.2.  
 
Note 1 to entry: MEL is measured as A - weighted levels in dB.  
Note 2 to entry: See B.3 of EN 50332 - 3:2017 for additional 
information.     N/A   

   
 
Page  69   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 3.3.19.3  
  sound exposure,  E  
 
A - weighted sound pressure ( p ) squared and 
integrated over a stated period of   time,  T  
 
Note 1 to entry: The SI unit is Pa 2
  s.  
    N/A  
3.3.19.4  
  sound exposure level,  SEL  
 
logarithmic measure of sound exposure relative to a 
reference value,  E 0 , typically the 1 kHz  
threshold of hearing in humans.  
 
Note 1 to entry:  SEL  is measured as  A - weighted levels in dB.  
 
dB  
 
Note 2 to entry: See B.4 of EN 50332 - 3:2017 for additional 
information.     N/A  
3.3.19.5  
  digital signal level relative to full scale, dBFS  
 
levels reported in dBFS are always r.m.s. Full scale 
level, 0 dBFS, is the level of a  dc - free 997 -  
Hz sine wave whose undithered positive peak value 
is positive digital full scale, leaving the code  
corresponding to negative digital full scale unused  
 
Note 1 to entry: It is invalid to use dBFS for non - r.m.s. levels. 
Because the definition of   full scale is based on a sine wave, the 
level of signals with a crest factor lower than that of a sine wave 
may exceed 0 dBFS. In particular, square wave signals may 
reach +3,01 dBFS.     N/A  
2   Modification to Clause 10  
N/A  
10.6   Safeguards against acoustic   energy sources  
Replace 10.6 of IEC 62368 - 1 with the following:   N/A  
10.6.1.1   Introduction  
 
Safeguard  requirements for protection against long -
term exposure to excessive sound pressure  
levels from personal music players closely coupled 
to the ear are speci fied below. Requirements  
for earphones and headphones intended for use 
with personal music players are also covered.  
A personal music player is a portable equipment 
intended for use by an  ordinary person , that:  
 
  –   is designed to allow the user to listen t o audio or 
audiovisual content / material; and     N/A     

   
 
Page  76   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  10.6.6.1   Corded listening devices with analogue input  
 
With 94 dB  L Aeq  acoustic pressure output of the 
listening device, and with the volume and sound 
settings in the listening device (for example, built - in 
volume leve l control, additional sound features like 
equalization, etc.) set to the combination of positions 
that maximize the measured acoustic output, the 
input voltage of the listening device when playing the 
fixed “programme simulation noise” as described in 
EN 5 0332 - 1 shall be  ≥  75 mV.  
 
NOTE The values of 94 dB and 75 mV correspond with 85 dB 
and 27 mV or 100 dB and 150 mV.     N/A  
10.6.6.2   Corded listening devices with digital input  
 
With any playing device playing the fixed 
“programme simulation noise” described in EN 
50332 - 1, a nd with the volume and sound settings in 
the listening device (for example, built - in volume 
level control, additional sound features like 
equalization, etc.) set to the combination of positions 
that maximize the measured acoustic output, the 
L Aeq , T  acousti c output of the listening device shall be 
≤  100 dB with an input signal of  - 10 dBFS.     N/A  
10.6.6.3   Cordless listening devices  
 
In cordless mode,  
–   with any playing and transmitting device playing 
the fixed programme simulation noise described in 
EN 50332 - 1; and  
–   respecting the cordless transmiss ion standards, 
where an air interface standard exists that specifies 
the equivalent acoustic level; and  
–   with volume and sound settings in the receiving 
device (for example, built - in volume level control, 
additional sound features like equalization, etc.)   set 
to the combination of positions that maximize the 
measured acoustic output for the above mentioned 
programme simulation noise, the  L Aeq , T  acoustic 
output of the listening device shall be  ≤  100 dB with 
an input signal of  - 10 dBFS.     N/A  
10.6.6.4   Measurement method  
 
Measurements shall be made in accordance with EN 
50332 - 2 as applicable.     N/A  
3  
Modification to the whole document  
P   

   
 
Page  79   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
8  
Modification to 10.5.1  
N/A  
10.5.1   Add   the following after the first paragraph:  
 
For RS 1 compliance is checked by measurement 
under the fol lowing conditions:  
 
In addition to the normal operating conditions, all 
controls adjustable from the outside by hand, by any 
object such as a tool or a coin, and those internal 
adjustments or pre - sets which are not locked in a 
reliable manner, are adjusted   so as to give 
maximum radiation whilst maintaining an intelligible 
picture for 1 h, at the end of which the measurement 
is made.  
 
NOTE Z1 Soldered joints and paint lockings are examples of 
adequate locking.  
 
The dose - rate is determined by means of a radia tion 
monitor with an effective area of 10 cm², at any point 
10 cm from the outer surface of the apparatus.  
 
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high 
voltage, provided an intelligible picture is maintain ed 
for 1 h, at the end of which the measurement is 
made.  
 
For RS1, the dose - rate shall not exceed 1  μSv/h 
taking account of the background level.  
 
NOTE Z2 These values appear in Directive 96/29/Euratom of 13 
May 1996.     N/A  
9  
Modification to G.7.1  
N/A  
G.7.1   Add  the following note:  
 
NOTE Z1 The harmonized code designations corresponding to 
the IEC cord t ypes are given in Annex   ZD.     N/A   

   
 
Page  83   of  88   Report No. :  60404490 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TRF No.  IEC62368_1 C    
 5.6.4.2.1   France  
 
After the indent for  pluggable equipment type A , 
the following is added:  
–   in certain cases, the  protective current rating  of 
the circuit supplied from the mai ns is taken as 20 A 
instead of 16 A.     N/A  
5.6.5.1   To the second paragraph the following is added:  
 
The range of conductor sizes of flexible cords to be 
accepted by terminals for equipment with a rated 
current over 10 A and up to and including 13 A is:  
1,2 5 mm 2
  to 1,5 mm 2
  in cross - sectional area.     N/A  
5.6.8   Norway  
 
To the end of the subclause the following is added:  
Equipment connected with an earthed mains plug is 
classified as  class I equipment . See the Norway 
marking requirement in 4.1.15. The symbol IE C 
60417 - 6092, as specified in F.3.6.2, is accepted .     N/A  
5.7.6   Denmark  
 
To the end of the subclause the following is added:  
 
The installation instruction shall be affixed to the 
equipment if the  protective conductor current 
exceeds the limits of 3,5 mA a. c. or 10 mA d.c.     N/A  
5.7.6.2   Denmark  
 
To the end of the subclause the following is added:  
The warning (marking safeguard) for high touch 
current is required if the touch current or the 
protective current exceed the limits of 3,5 mA .     N/A  
5.7.7.1   Norway   and Sweden  
 
To the end of the subclause the following is added:  
The screen of the television distribution system is 
normally not earthed at the entrance of the building 
and there is normally no equipotential bonding 
system within the building.  
Therefore t he protective earthing of the building 
installation needs to be isolated from the screen of a 
cable distribution system.  
 
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic iso lator, which 
may be provided by a retailer, for example.  
 
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what country 
the equipment is intended to be used in:  
 
“Apparatus   connected to the protective earthing of    N/A