Page 17 of 616
H11
Normal Charge
You can charge your vehicle by plug-
ging into a public charger at a charg-
ing station.
How to Connect Normal Charger
1. Depress the brake pedal andapply the parking brake.
2. Turn OFF all switches, move the shift lever to P (Park), and turn
OFF the vehicle.
3. After unlocking doors, open the charging door by pressing it.
✽ ✽NOTICE
The charging door does not open the
doors are locked/theft alarm system
is armed.
4. Remove any dust on the charging
connector and charging inlet.
5. Hold the charging connector han- dle. Then, insert it into the charg-
ing inlet, until you hear a click
sound. If it is not fully connected, a
bad connection between the
charging connector and the charg-
ing terminals may cause a fire.ODEPQ017025
OJFHPQ016021L
OAEEQ016028
■Normal Charger
■Normal charger cableODEPQ017026
Page 18 of 616

H12
6. Check if the charging cable con-nection indicator of the high volt-
age battery in the instrument clus-
ter is turned ON.
Charging does not occur when the
indicator is OFF. When the charg-
ing connector is not connected
properly, reconnect the charging
cable to charge.
✽ ✽ NOTICE
• Charging is in progress only when
the shift lever is in P (Park).
Charging the battery with the
Engine Start/Stop button in the
ACC position is possible. However,
it may discharge the 12-V battery.
Thus, if possible, charge the bat-
tery with the Engine Start/Stop
button in the OFF position.
• The charging process is interrupt- ed temporarily when the shift lever
is moved from P (Park) to Not P(R
(Reverse)/N (Neutral)/D (Drive))
during charging. To resume(restart)
charging, move the shift lever to the
P (park) position. Then, the charging
process is resumed(restarted).
7. After charging has started, the
estimated charging time is dis-
played on the instrument cluster
for about 1 minute. It is also dis-
played, when the driver’s door is
opened with charging in progress.
When scheduled charging is set,
the estimated charging time is dis-
played as “--" .
ODEPQ017027
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
ODEPQ017028L
Page 19 of 616
H13
Unlock Connector in Emergency
If the charging connector does not
unlock for some reason, open the
hood and slightly pull the emergency
cable as shown above. The charging
door will then open.
If a charging door is not opened
immediately with emergency cable in
operation, press a charging door
lightly and pull emergency cable
again.
Charging Status
Checking Charging Status
You can check the charging status at
the outside of vehicle when charging
or using (it is not driving status) the
high-voltage battery.
ODEPQ017029
ODEP047020N
Operation of
Charging Indicator Lamp (1)
Charging Status
Turns on (Green)Charging inprogress
Turns offNot Charging or fully charged
Slowly blinks
(Green) and then turns off (repeat for 3 minutes)Waiting for sched- uled charging
(turns off after 3 minutes)
Quickly
blinks(Green) and then turns off
(repeats during operation)
Aux. Battery Saver+ operating in progress
Slowly blinks (Red)Malfunction
Page 20 of 616

H14
How to Disconnect NormalCharger
1.The vehicle must be in the AUTO mode or the doors must be
unlocked in order to be able to dis-
connect the charging connector. A
lock system prevents charger
cable disconnection when the vehi-
cle's doors are locked.
2.While holding the charging con-nector, pressing the locking
release button (1) and then pull it
out.
To prevent charging cable theft, the
charging connector cannot be dis-
connected from the inlet when the
doors are locked. Unlock all doors
to disconnect the charging connec-
tor from the inlet.
However, if the vehicle is in the
charging connector AUTO mode,
the charging connector automati-
cally unlocks from the inlet when
charging is completed. For more details, refer to “Charging
Connector AUTO/ LOCK Mode” in
this chapter.
ODEPQ017031
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
CAUTION
In order to disconnect the
charging connector, unlock thedoors to unlatch the chargingconnector lock system. If not,the charging connector and thevehicle's charging inlet may bedamaged.
CAUTION
When disconnecting the charg-ing connector, do not try to dis-connect it by force while notpressing the release button.This may damage the chargingconnector and vehicle charginginlet.
Page 21 of 616
H15
3. Make sure to securely close thecharging door.
✽
✽NOTICE
• Keep the charging connector and
the charging plug clean and dry.
The charging cable should also be
kept dry.
• Use an air gun to blow any foreign substances from the charging con-
nector and the charging plug.
Trickle Charger
(Portable Charging Cable)
Trickle charger can be used if
Normal Charger is unavailable.
❈➀ : Plug and cable
➁ : Control box (ICCB)
➂ : Charging connector/cable
OAEEQ016042
ODEPQ017032
WARNING
Do not modify or disassemble
the charging cable compo-
nents. Doing so may cause a
fire or electric shock resulting
in personal injuries.
Page 22 of 616
H16
How to Connect PortableCharging Cable (ICCB: In-Cable Control Box)
1. Turn OFF all switches, move the shift lever to P (Park), and turn
OFF the vehicle.
2. Depress the brake pedal and apply the parking brake. 3. After unlocking doors, open the
charging door by pressing it. 4. Connect the plug to a household
electric outlet.
5. Make sure that the power connec- tion indicator (green) lights in the
control box.
✽ ✽NOTICE
The charging door does not open
when the theft alarm system is
armed.
ODEPQ017025ODEPQ017047
OJFHPQ016015N
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)
Page 23 of 616
H17
6. Remove any dust on the chargingconnector and charging inlet.
7. Hold the charging connector han- dle. Then, insert it into the charging
inlet, until you hear a click sound. If
it is not fully connected, improper
connection between the charging
connector and the charging termi-
nals are a potential fire hazard. 8. Charging starts automatically and
the charging light blinks. 9. Check if the charging cable con-
nection indicator of the high volt-
age battery in the instrument clus-
ter is turned ON.
Charging does not occur when the
indicator is OFF. When the charg-
ing connector is not connected
properly, reconnect the charging
cable to charge.
ODEPQ017035ODEPQ017027
ODEPQ017049
ODEPQ017048
■ Vehicle connection ■
Charge
Page 24 of 616

H18
✽
✽NOTICE
• The charging is in progress only
with the shift lever is in P (Park).
Charging the battery with the
Engine Start/Stop button in the
ACC position is possible. However,
it may discharge the 12-V battery.
Thus, if possible, charge the bat-
tery with the Engine Start/Stop
button in the OFF position.
• Moving the shift lever from P (Park) to R (Reverse)/N(Neutral)/D
(Drive) stops the charging process.
To restart the charging process,
move the shift lever to P (Park),
press the Engine Start/Stop button
to the OFF position, and discon-
nect the charging cable. Then,
connect the charging cable and
restart the vehicle again.
10. After charging has started, the
estimated charging time is dis-
played on the instrument cluster
for about 1 minute. It is also dis-
played, when the driver’s door is
opened with charging in progress.
When scheduled charging is set,
the estimated charging time is dis-
played as "--".
Unlock Connector in Emergency
If the charging connector does not
unlock for some reason, open the
hood and slightly pull the emergency
cable as shown above. The charging
door will then open.
If a charging door is not opened
immediately with emergency cable in
operation, press a charging door
lightly and pull emergency cable
again.
ODEPQ017028L
ODEPQ017029
CHARGING THE PLUG-IN HYBRID VEHICLE (CONT.)