SHIFT LOCK SYSTEMTM-369
< DTC/CIRCUIT DIAGNOSIS > [CVT: RE0F10E]
C
EF
G H
I
J
K L
M A
B
TM
N
O P
SHIFT LOCK SYSTEM
Component Function CheckINFOID:0000000009464325
1.CHECK SHIFT LOCK OPERATION (PART 1)
1. Turn ignition ON.
2. Shift the selector lever to “P” (Park) position.
3. Attempt to shift the selector lever to any other than position with the brake pedal released.
Can the selector lever be shifted to any other position?
YES >> Go to TM-369, "Diagnosis Procedure".
NO >> GO TO 2.
2.CHECK SHIFT LOCK OPERATION (PART 2)
Attempt to shift the selector lever to any other than position with the brake pedal depressed.
Can the selector lever be shifted to any other position?
YES >> Inspection End.
NO >> Go to TM-369, "Diagnosis Procedure"
.
Diagnosis ProcedureINFOID:0000000009953347
Regarding Wiring Diagram information, refer to TM-275, "Wiring Diagram".
1. CHECK POWER SOURCE (STOP LAMP SWITCH)
1. Turn ignition switch OFF.
2. Disconnect stop lamp switch connector.
3. Check voltage between stop lamp switch connector E38 terminal 1 and ground.
Is the inspection result normal?
YES >> GO TO 2.
NO >> Check the following: • Harness for short or open between fuse block (J/B) and stop lamp switch
• 10A fuse (No. 10, located in fuse block [J/B])
2.CHECK STOP LAMP SWITCH
Check stop lamp switch. Refer to TM-372, "Component Inspection (Stop Lamp Switch)"
.
Is the inspection result normal?
YES >> GO TO 3.
NO >> Replace stop lamp switch. Refer to BR-18, "Exploded View"
.
3.CHECK HARNESS BETWEEN STOP LAMP SWITCH AND STOP LAMP RELAY
1. Check continuity between stop lamp relay connector E57 terminal 2 and stop lamp switch connector E38
terminal 2.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace damaged parts.
Stop lamp switch
GroundVoltage
Connector Terminal
E38 1 Battery voltage
Stop lamp switch Stop lamp relay Continuity
Connector Terminal Connector Terminal
E38 2 E57 2 Yes
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM