EC-974
< DTC/CIRCUIT DIAGNOSIS >[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Component Function CheckINFOID:0000000009462856
1.CHECK ORVR FUNCTION
Check whether the following symptoms are present.
• Fuel odor from EVAP canister is strong.
• Cannot refuel/Fuel odor from the fuel filler opening is strong while refueling.
Are any symptoms present?
YES >> Proceed to EC-974, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000009462857
1.INSPECTION START
Check whether the following symptoms are present.
A: Fuel odor from EVAP canister is strong.
B: Cannot refuel/Fuel odor from the fuel filler opening is strong while refueling.
A or B
A>>GO TO 2.
B>>GO TO 7.
2.CHECK EVAP CANISTER
1. Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached. Refer to FL-14, "Removal and Installation"
.
2. Weigh the EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be l ess than 2.1 kg (4.6 lb).
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 4.
3.CHECK IF EVAP CANISTER IS SATURATED WITH WATER
Check if water will drain from EVAP canister
Does water drain from the EVAP canister?
YES >> GO TO 4.
NO >> GO TO 6.
4.REPLACE EVAP CANISTER
Replace EVAP canister with a new one. Refer to FL-14, "Removal and Installation"
.
>> GO TO 5.
5.DETECT MALFUNCTIONING PART
Check the EVAP hose between EVAP canister and vehicle frame for clogging or poor connection.
>> Repair or replace EVAP hose. Refer to FL-16, "Removal and Installation"
.
6.CHECK REFUELING EVAP VAPOR CUT VALVE
Check refueling EVAP vapor cut valve. Refer to EC-976, "Component Inspection"
.
JMBIA1134GB
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
ON BOARD REFUELING VAPOR RECOVERY (ORVR)EC-975
< DTC/CIRCUIT DIAGNOSIS > [VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
NP
O
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace refueling EVAP vapor cut valve with fuel tank. Refer to FL-10, "Removal and Installation"
.
7.CHECK EVAP CANISTER
1. Remove EVAP canister with EVAP canister vent c ontrol valve and EVAP control system pressure sensor
attached. Refer to FL-14, "Removal and Installation"
.
2. Weigh the EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor
attached.
The weight should be l ess than 2.1 kg (4.6 lb).
Is the inspection result normal?
YES >> GO TO 8.
NO >> GO TO 9.
8.CHECK IF EVAP CANISTER IS SATURATED WITH WATER
Check if water will drain from EVAP canister.
Does water drain from the EVAP canister?
YES >> GO TO 6.
NO >> GO TO 11.
9.REPLACE EVAP CANISTER
Replace EVAP canister with a new one. Refer to FL-14, "Removal and Installation"
.
>> GO TO 10.
10.DETECT MALFUNCTIONING PART
Check the EVAP hose between EVAP canister and vehicle frame for clogging or poor connection.
>> Repair or replace EVAP hose. Refer to FL-16, "Removal and Installation"
.
11 .CHECK VENT HOSES AND VENT TUBES
Check hoses and tubes between EVAP c anister and refueling control valve for clogging, kinks, looseness and
improper connection.
Is the inspection result normal?
YES >> GO TO 12.
NO >> Repair or replace hoses and tubes.
12.CHECK FILLER NECK TUBE
Check recirculation line for clogging, dents and cracks.
Is the inspection result normal?
YES >> GO TO 13.
NO >> Replace filler neck tube.
13.CHECK REFUELING EVAP VAPOR CUT VALVE
Check refueling EVAP vapor cut valve. Refer to EC-976, "Component Inspection"
.
Is the inspection result normal?
YES >> GO TO 14.
NO >> Replace refueling EVAP vapor cut valve with fuel tank. Refer to FL-10, "Removal and Installation"
.
14.CHECK FUEL FILLER TUBE
Check filler neck tube and hose connected to the fuel tank for clogging, dents and cracks.
JMBIA1134GB
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
EC-976
< DTC/CIRCUIT DIAGNOSIS >[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Is the inspection result normal?
YES >> GO TO 15.
NO >> Replace fuel filler tube. Refer to FL-10, "Removal and Installation"
.
15.CHECK ONE-WAY FUEL VALVE-I
Check one-way valve for clogging.
Is the inspection result normal?
YES >> GO TO 16.
NO >> Repair or replace one-way fuel valve with fuel tank. Refer to FL-10, "Removal and Installation"
.
16.CHECK ONE-WAY FUEL VALVE-II
1. Check that fuel is drained from the tank.
2. Remove fuel filler tube and hose. Refer to FL-10, "Removal and Installation"
.
3. Check one-way fuel valve for operation as per the following.
When a stick is inserted, the valve should open, when removing
stick it should close.
Do not drop any material into the tank.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace fuel filler tube or replace one-way fuel valve
with fuel tank. Refer to FL-10, "Removal and Installa-
tion".
Component InspectionINFOID:0000000009462858
1.INSPECTION START
Will CONSULT be used?
Will CONSULT be used?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK REFUELING EVAP VAPOR CUT VALVE
With CONSULT
1. Turn ignition switch OFF.
2. Remove fuel tank. Refer to FL-10, "Removal and Installation"
.
3. Drain fuel from the tank as per the following:
- Remove fuel feed hose located on the fuel gauge retainer. Refer to FL-10, "Removal and Installation"
.
- Connect a spare fuel hose, one side to fuel gauge re tainer where the hose was removed and the other
side to a fuel container.
- Drain fuel using “FUEL PUMP RELAY” in “ACTIVE TEST” mode with CONSULT.
4. Check refueling EVAP vapor cut valve for being stuck to close as per the following. Blow air into the refueling EVAP vapor cut valv e (from the end of EVAP/ORVR line hose), and check that
the air flows freely into the tank.
5. Check refueling EVAP vapor cut valve for being stuck to open as per the following.
- Connect vacuum pump to hose end.
- Remove fuel gauge retainer with fuel gauge unit.
Always replace O-ri ng with new one.
- Turn fuel tank upside down.
- Apply vacuum pressure to hose end [ −13.3 kPa ( −0.136 kg/cm
2, −1.93 psi)] with fuel gauge retainer
remaining open and check that the pressure is applicable.
SEF665U
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
ON BOARD REFUELING VAPOR RECOVERY (ORVR)EC-977
< DTC/CIRCUIT DIAGNOSIS > [VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
NP
O
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace refueling EVAP vapor cut valve with fuel tank. Refer to FL-10, "Removal and Installation"
.
3.CHECK REFUELING EVAP VAPOR CUT VALVE
Without CONSULT
1. Turn ignition switch OFF.
2. Remove fuel tank. Refer to FL-10, "Removal and Installation"
.
3. Drain fuel from the tank as per the following:
- Remove fuel gauge retainer.
- Drain fuel from the tank using a handy pump into a fuel container.
4. Check refueling EVAP vapor cut valve for being stuck to close as per the following. Blow air into the refueling EVAP vapor cut valv e (from the end of EVAP/ORVR line hose), and check that
the air flows freely into the tank.
5. Check refueling EVAP vapor cut valve for being stuck to open as per the following.
- Connect vacuum pump to hose end.
- Remove fuel gauge retainer with fuel gauge unit. Always replace O-ring with new one.
- Turn fuel tank upside down.
- Apply vacuum pressure to hose end [ −13.3 kPa ( −0.136 kg/cm
2, −1.93 psi)] with fuel gauge retainer
remaining open and check that the pressure is applicable.
1. Filler tube 2. Recirculation line 3. EVAP/ORVR line
4. Vacuum/pressure handy pump 5. Fuel tank
JPBIA5852ZZ
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
EC-978
< DTC/CIRCUIT DIAGNOSIS >[VQ35DE]
ON BOARD REFUELING VAPOR RECOVERY (ORVR)
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace refueling EVAP vapor cut valve with fuel tank. Refer to FL-10, "Removal and Installation"
.
1. Filler tube 2. Recirculation line 3. EVAP/ORVR line
4. Vacuum/pressure handy pump 5. Fuel tank
JPBIA5852ZZ
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
REFRIGERANT PRESSURE SENSOREC-979
< DTC/CIRCUIT DIAGNOSIS > [VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
NP
O
REFRIGERANT PRESSURE SENSOR
Component Function CheckINFOID:0000000009462859
1.CHECK REFRIGERANT PRE
SSURE SENSOR FUNCTION
1. Start engine and warm it up to normal operating temperature.
2. Turn A/C switch and blower fan switch ON.
3. Check the voltage between ECM harness connector terminals under the following conditions.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Proceed to EC-979, "Diagnosis Procedure"
.
Diagnosis ProcedureINFOID:0000000009462860
1.CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
1. Disconnect refrigerant pressu re sensor harness connector.
2. Turn ignition switch ON.
3. Check the voltage between refrigerant pr essure sensor harness connector and ground.
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK REFRIGERANT PRESSURE SE NSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between refrigerant pre ssure sensor harness connector and ECM harness connec-
tor.
Is the inspection result normal?
YES >> Perform the trouble diagnosis for power supply circuit.
NO >> Repair or replace error-detected parts.
3.CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check the continuity between refrigerant pre ssure sensor harness connector and ECM harness connec-
tor.
ECM
Voltage (V)
Connector +–
Te r m i n a l
F79 63 64 1.0 - 4.0
Refrigerant pressure sensor Ground Voltage (V)
Connector Terminal
E219 1 Ground Approx. 5
Refrigerant pressure sensor ECM Continuity
Connector Terminal Connector Terminal
E219 1 F79 96 Existed
Refrigerant pressure sensor ECM Continuity
Connector Terminal Connector Terminal
E219 3 F79 64 Existed
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
EC-980
< DTC/CIRCUIT DIAGNOSIS >[VQ35DE]
REFRIGERANT PRESSURE SENSOR
4. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace error-detected parts.
4.CHECK REFRIGERANT PRESSURE SENSOR INPU T SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check the continuity between refrigerant pre ssure sensor harness connector and ECM harness connec-
tor.
2. Also check harness for short to ground and short to power.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace error-detected parts.
5.CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to GI-43, "Intermittent Incident"
.
Is the inspection result normal?
YES >> Replace refrigerant pressure sensor. Refer to HA-39, "REFRIGERANT PRESSURE SENSOR :
Removal and Installation".
NO >> Repair or replace error-detected parts.
Refrigerant pressure sensor ECM Continuity
Connector Terminal Connector Terminal
E219 2 F79 63 Existed
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM
SENSOR POWER SUPPLY2 CIRCUITEC-981
< DTC/CIRCUIT DIAGNOSIS > [VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
NP
O
SENSOR POWER SUPPLY2 CIRCUIT
DescriptionINFOID:0000000009462861
ECM supplies a voltage of 5 V to some of the sensors systematically divided into 2 groups, respectively.
Accordingly, when a short circuit develops in a sensor power source, a malfunction may occur simultaneously
in the sensors belonging to the same group as the short-circuited sensor.
Sensor power supply 1
• Accelerator pedal position (APP) sensor 1
• Camshaft position (CMP) sensor (PHASE)
• Electric throttle control actuator
• Battery current sensor
NOTE:
If sensor power supply 1 circuit is malfunctioning, DTC P0643 is displayed.
Sensor power supply 2
• Accelerator pedal position (APP) sensor 2
• Crankshaft position (CKP) sensor (POS)
• Refrigerant pressure sensor
• EVAP control system pressure sensor
• Engine oil pressure sensor
Diagnosis ProcedureINFOID:0000000009462862
1.CHECK SENSOR POWER SUPPLY 1
1. Turn ignition switch OFF.
2. Disconnect ECM harness connectors
3. Turn ignition switch ON.
4. Check the voltage between ECM harness connector and ground.
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI-43, "Intermittent Incident".
NO >> GO TO 2.
2.CHECK SENSOR POWER SUPPLY 2 CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect following sensors harness connector.
3. Check harness for short to power and short to ground, between the following terminals.
+
−Vo l ta g e
(Approx.)
ECM
Connector Terminal
F79 54
Ground 5 V
96
E32 103
107
ECM Sensor + Name +
Connector Terminal Connector Terminal
F79 54 CKP sensor (POS) F30 1
96 Refrigerant pressure sensor E219 1
E32 103 APP sensor 2 E40 5
107
EVAP control system pressure sensor B41 3
EOP sensor F87 3
Revision: November 20132014 Altima NAMRevision: November 20132014 Altima NAM