Page 49 of 51
• Be careful that the engine crane does not contact
the trunk lid.
• Apply protection so that no scratches or other damage occurs on the vehicle body or trunk lid.
29. Remove the DC/DC converter inlet duct clips (A) and then the DC/DC converter inlet duct (1) . Touching high voltage components without wearing
appropriate
Personal Protective Equipment (PPE) will
cause electrocution.
30. Remove the battery cooling fan mounting bolts (A) and remove the battery cooling fan (1) . Touching high voltage components without wearing
appropriate
Personal Protective Equipment (PPE) will
cause electrocution. JSCIA0282ZZ
AAYIA0048ZZ
AAYIA0049ZZ
DG–49
Page 50 of 51
31. Confirm that the insulated tape is still securely in place on the high voltage battery pack as shown
in the figure. : Insulated tape
32.
Dismantling the remainder of the Q70 HYBRID may be performed like conventional Infiniti
vehicles once the high voltage system is properly shut down and discharged.
6-3 Li-ion Battery Recycling
The high voltage battery is recyclable. For information regarding recycling of the high voltage battery,
contact the nearest INFINITI retailer or Infiniti Consumer Affairs at: United States: 1-800-662-6200 or in
Canada: 1-800-361-4792. AAYIA0077ZZ
DG–50
Page 51 of 51
© 2013 Nissan North America, Inc.
All
rights reserved.
This document may not be altered without the written permission of Nissan North America, Inc.
Pub. No. DG14EAHY51U0
DG–51