2013 SSANGYONG KORANDO fuel

[x] Cancel search: fuel

Page 382 of 1336

SSANGYONG KORANDO 2013  Service Manual 0000-00
c. Fuel Injection Control
Injection control is used in order to determine the characteristics of the pulse which is sent to the 
injectors.
Injection control consists as below.
Injection timin

Page 383 of 1336

SSANGYONG KORANDO 2013  Service Manual Pilot injection timing control
The pilot injection timing is determined as a function of the engine speed and of the total flow.
The elements are:
A first correction is made according to the air and c

Page 384 of 1336

SSANGYONG KORANDO 2013  Service Manual 0000-00
2. Driver Demand
The driver demand is the translation of the pedal position into the fuel demand. It is calculated as a 
function of the pedal position and of the engine speed. The driver dema

Page 385 of 1336

SSANGYONG KORANDO 2013  Service Manual 3. Idle Speed Controller
The idle speed controller consists of 2 principal modules:
The first module determines the required idle speed according to:
* The operating conditions of the engine (coolant

Page 386 of 1336

SSANGYONG KORANDO 2013  Service Manual 0000-00
5. Pilot Flow Control
The pilot flow represents the amount of fuel injected into the cylinder during the pilot injection. This 
amount is determined according to the engine speed and the total

Page 387 of 1336

SSANGYONG KORANDO 2013  Service Manual e. MDP Learning Control
MDP (Minimum Drive Pulse ) refers to the 
minimum power supply pulse for injection which 
the injector can perform. It is possible to control 
the fuel volume for each injector

Page 388 of 1336

SSANGYONG KORANDO 2013  Service Manual 0000-00
(3) Accelerometer Control
a. Resetting the pilot injection
The accelerometer is used to reset the pilot injection flow in closed loop for each injector. This method 
allows the correction of a

Page 389 of 1336

SSANGYONG KORANDO 2013  Service Manual This is done periodically under certain operating conditions. When the resetting is finished, the new 
minimum pulse value replaces the value obtained during the previous resetting. The first MDP valu