13B-48
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF015
PRESENT
OR
STOREDMAIN RELAY CONTROL CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESSpecial notes:
The "injection control unit supply relay" (50A) is located on the relay plate, inside
the engine compartment connection unit.
Engine stalls or is impossible to restart.
If the fault is present:
The level 2 warning light is lit.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the condition of the battery (see MR 392, 385, 364, 370 and 417, Mechanical, 80A, Battery, Battery:
Removal - Refitting) and carry out fault finding on the charging circuit (see Technical Note 6014A, Charging
circuit check or 87G, Engine compartment connection unit).
Check the condition of the injection supply relay.
Check the injection system fuses (see MR 392, 385, 364, 370 and 417, Mechanical, 81C, Fuses, Fuses: List
and location of components).
Check the connection of the injection computer connector, component code120 (see MR 392, 385, 364, 370
and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
With the ignition on, check for + 12 V on connections BP of the UPC computer, component code 1337.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3FB1 between components 1337 and 120,
–3FB2 between components 1337 and 120,
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the main relay or test the Protection and Switching Unit computer (see
87G, Engine compartment connection unit).
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF015 / SID304_V45_DF015 / SID301_V48_DF015 / SID304_V49_DF015 / SID304_V4D_DF015 / SID301_V4C_DF015
13B-49
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF016
PRESENT
OR
STORED
EGR VALVE CONTROL CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CC : Short circuit
CO : Open circuit
1. DEF: Values outside limits
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present with the engine at idle speed.
Special notes:
EGR cut off.
If the fault is present:
– engine instability, possibly even stalling,
– engine starting is difficult or even impossible when cold,
– the OBD warning light is on.
Use the Wiring Diagram Technical Notes for CLIO III, MODUS, MEGANE II ph2,
SCENIC II ph2 and KANGOO II.
Check the connection and condition of the EGR valve connector, component code 1460 and check the connector
for the injection computer, component code 120.
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check for the presence of the supply: 13 V < X <14 V (engine running), 11.5 V < X < 12.5 V (ignition on,
engine stopped) on connection 3VP of component 1460.
Check for earth on connection3VQ of component1460.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3VP between components 1460 and 120,
–3VQ between components 1460 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Measure the resistance of the EGR valve, component code 1460:
– with the engine stopped, the EGR valve will be closed (unless there is a fault),
– wait for the ambient temperature to stabilise (approximately 20 ºC) around the valve,
– measure the resistance between connections3VP and 3VQ of component1460.
If the resistance is not between 0.5 Ω < X < 50 Ω, replace the EGR valve (see MR 392 (CLIO III), 385 (MODUS),
364 (MEGANE II), 370 (SCENIC II), 417 (KANGOO II), Mechanical, 14A, Emission control, Exhaust gas
recirculation solenoid valve: Removal - Refitting
).
Use the command RZ002 EGR Adaptive to reinitialise the offsets of the EGR valve (see Replacement of
components).
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF016 / SID304_V45_DF016 / SID301_V48_DF016 / SID304_V49_DF016 / SID304_V4D_DF016 / SID301_V4C_DF016
13B-58
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF039
PRESENT
OR
STOREDINLET AIR TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Open circuit or short circuit to +12 V.
1. DEF: Micro-breaks
NOTESProcessing priority in the event of a number of faults:
Deal with fault DF011 Sensor supply voltage no. 1 first if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the ignition has been switched on for at least
10 seconds.
If the fault is present:
The air temperature has a default value, which is PR059 Inlet air temperature =
40°C.
Illumination of OBD fault warning light on the instrument panel.
Special notes:
The inlet air temperature sensor is integrated into the air flowmeter.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the connector for the flowmeter, component code799 (see MR 392, 364,
370 and 417, Mechanical, 12A, Fuel mixture, Air flowmeter: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the air temperature sensor between connections 3ABQ and 3DW of the air
flowmeter component code 799.
If the resistance measured is not:
3553Ω
flowmeter: Removal - Refitting)
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3ABQ
, between components799 and 120,
–3DW between components 799 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF039 / SID304_V45_DF039 / SID301_V48_DF039 / SID304_V49_DF039 / SID304_V4D_DF039 / SID301_V4C_DF039
13B-59
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF047
PRESENT
OR
STOREDCOMPUTER SUPPLY VOLTAGE
1. DEF: Signal outside lower limit
2. DEF: Signal outside upper limit
NOTESProcessing priority in the event of a number of faults:
Deal with fault DF532 Alternator charge signal first if the fault is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
– The fault is declared present with the engine running.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the battery and run fault finding on the charging circuit (see Technical Note 6014A, Checking the
charging circuit or 87G, Engine compartment connection unit).
Check the connection and condition of the injection computer connectors, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
Check the engine and chassis earths.
Check the condition of the relay support plate as well as the positioning and condition of the injection supply
relay, component code 983.
Replace the relay if necessary (see Replacement of components).
With the ignition on, check for the presence of +12 V on the connectionsBP of the main relay support plate,
component code 983 or the Protection and Switching Unit computer, component code 1337.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3FB between components983 and 120,
–M between components120 and ME (Bodywork electrical earth).
Or (for Kangoo II):
–3FB1 between components 1337 and 120,
–3FB2 between components 1337 and 120,
–N between component 120 and the earth.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF047 / SID304_V45_DF047 / SID301_V48_DF047 / SID304_V49_DF047 / SID304_V4D_DF047 / SID301_V4C_DF047
13B-60
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF049
PRESENT
OR
STOREDREFRIGERANT SENSOR CIRCUIT
CC.0: Short circuit to earth
CO.1: Open circuit or short circuit to + 12 V
NOTESProcessing priority in the event of a number of faults:
First deal with the fault DF012 Sensor supply voltage no. 2 if the fault is present or
stored.
Conditions for applying the fault finding procedure to a stored fault:
Apply the fault finding procedure below, whether the fault is present or stored.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the connector for the refrigerant fluid pressure sensor, component
code1202 (see MR 392, 385, 364, 370 and 417, Mechanical, 62A, Air conditioning, Pressure sensor:
Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
With the ignition on, check for the presence of + 5 V on connection 38Y and an earth on connection38U of the
refrigerant fluid pressure sensor.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–38Y between components1202 and 120,
–38X between components1202 and 120,
–38U between components1202 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the
refrigerant fluid sensor (see MR 392, 385, 364, 370 and 417, Mechanical,
62A, Air conditioning, Pressure sensor: Removal - Refitting).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF049 / SID304_V45_DF049 / SID301_V48_DF049 / SID304_V49_DF049 / SID304_V4D_DF049 / SID301_V4C_DF049
13B-61
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF051
PRESENT
OR
STOREDCRUISE CONTROL/SPEED LIMITER FUNCTION
CC.1 : Short circuit to + 12 V
1. DEF: Values outside limits
2. DEF: Signal outside upper limit
3. DEF: Signal inconsistency
NOTESSpecial notes:
If a fault is present, the cruise control/speed limiter is inhibited.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the connector for the ON/OFF button of the cruise control/speed limiter
function, component code1081 (or component code1546 for Scénic II) (see MR 392, 385, 364, 370 and 417,
Mechanical, 83D, Cruise control, Cruise control - speed limiter: List and location of components) and the
injection computer connector, component code120 (see MR 392, 385, 364, 370 and 417, Mechanical, 13B,
Diesel injection, Diesel injection computer: Removal - Refitting).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
Check for the presence of + 12 V after ignition feed on connection AP10 (AP43 for Kangoo II) of the ON/OFF
button of the cruise control/speed limiter function, component code 1081 (or component code 1546 for
Scénic II).
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3PD between components120 and 1081 (or 1546 for Scénic II),
–3FX between components120 and 1081 (or 1546 for Scénic II).
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the operation of the ON/OFF switch for the cruise control/speed limiter function and consult the
interpretation of ET042 cruise control/speed limiter (see Interpretation of statuses).
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF051 / SID304_V45_DF051 / SID301_V48_DF051 / SID304_V49_DF051 / SID304_V4D_DF051 / SID301_V4C_DF051
13B-63
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF054
PRESENT
OR
STOREDTURBOCHARGING SOLENOID VALVE CONTROL CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the engine is started,
– a road test,
– an actuator control AC214 Turbocharger control solenoid valve.
If the fault is present:
Loss of performance with Level 1 warning light coming on.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the turbocharging solenoid valve connector, component code1475.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the turbocharging solenoid valve, component code1475 between its
connections3FB (3FB3 for Kangoo II) and 3MG:
If the resistance measured is not 19Ω
With the ignition on, check for the presence of + 12 V after ignition feed on connection3FB (3FB3 for
Kangoo II) of the turbocharging solenoid valve, component code1475.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3FB (except Kangoo II) between components 1475 and 120,
–3FB3 (Kangoo II only) between components 1475 and
1337,
–3MG between components1475 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF054 / SID304_V45_DF054 / SID301_V48_DF054 / SID304_V49_DF054 / SID304_V4D_DF054 / SID301_V4C_DF054
13B-64
MR-372-J84-13B050$429.mif
V17
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF056
PRESENT
OR
STOREDAIR FLOWMETER CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
NOTESProcessing priority in the event of a number of faults:
Deal with fault DF011 Sensor supply voltage no. 1 first if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the ignition has been switched on.
The level 1 and OBD warning lights are lit.
If the fault is present:
Loss of performance with smoke from the exhaust.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the flowmeter connector, component code 799 (see MR 392, 364, 370
and 417, Mechanical, 12A, Fuel mixture, Air flowmeter: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
With the ignition on, check for + 12 V on connection 3FB (or 3FB3 for Kangoo II), + 5 V on connection 3KJ and
earth on connection 3DW of the air flowmeter, component code 799.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3ABQ between components799 and 120,
–3DV between components 799 and 120,
–3DW between components 799 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair),
repair the wiring, otherwise replace it.
With the flow sensor connected, the vehicle ignition on and the engine stopped:
Measure the voltage between connections 3DV and 3DW of the air flowmeter, component code 799.
If the voltage is not between 0.3 V and 0.7 V, replace the air flowmeter (see MR 392, 364, 370 and 417,
Mechanical, 12A, Fuel mixture, Air flowmeter: Removal - Refitting).
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF056 / SID304_V45_DF056 / SID301_V48_DF056 / SID304_V49_DF056 / SID304_V4D_DF056 / SID301_V4C_DF056
MR-372-J84-13B050$429.mif
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4CProgram No.: B1 and B2