13B-76V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF033
PRESENT
OR
STOREDTHERMOPLUNGER 2 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC064 Thermoplunger no. 2 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF033/EDC16C36_V58_DF033
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
13B-77V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF033
CONTINUED
Check the supply to thermoplungers 2 and 3:
– Disconnect the connector of component 1072.
– Connect a test light between connection 3JC of component 1072 and a chassis earth.
– Run command AC064 Thermoplunger no. 2 relay.
– Disconnect the connector of component 1073.
– Connect a test light between connection 3JD of component 1073 and a chassis earth.
– Run command AC064 Thermoplunger no. 2 relay.
If the test light comes on correctly, measure the resistance of thermoplunger 2 and 3 between the following
connections:
–3JC of component 1072 and a chassis earth,
–3JD of component 1073 and a chassis earth.
If the resistance is greater than 2 Ω, replace thermoplunger 2 or 3.
If the test light does not come on, check the continuity and insulation of the following connections:
– Connection code 3JC between components 1550 and 1072.
– Connection code 3JD between components 1550 and 1073.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JAA and BP27 of component 1550.
– Run command AC064 Thermoplunger no. 2 relay.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JAA between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
13B-78V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF034
PRESENT
OR
STOREDTHERMOPLUNGER 3 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC031 Thermoplunger no. 3 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF034/EDC16C36_V58_DF034EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
13B-79V9 MR-372-J84-13B450$102.mif
13B
DF034
CONTINUED
Check the supply to thermoplunger 4:
– Disconnect the connector of component 1074.
– Connect a test light between connection 3JAC of component 1074 and a chassis earth.
– Run command AC031 Thermoplunger relay no.3.
If the test light illuminates correctly, measure the resistance of the thermoplunger 4 between the following
connection:
–3JAC of component 1074 and a chassis earth,
If the resistance is greater than 2Ω, replace thermoplunger 4.
If the test light does not come on, check the continuity and insulation of the following connection:
– Connection code 3JAC between components 1550 and 1074.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JAB and BP27 of component 1550.
– Run command AC031 Thermoplunger relay no.3.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JAB between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
DIESEL INJECTION
Fault finding – Interpretation of faults
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
13B-100V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF059
CONTINUED
DF059 appears on the diagnostic tool when the engine management computer has detected a fault during the
combustion phase several times in succession.
Several components may be responsible:
– the piston rings,
– the piston,
– the valves,
– the injector,
– the heater plug sealing.
If the fault is present:
– remove the injector concerned,
– if there is no obvious fault in the way the injector has been fitted (notably the injector washer), swap the injector
with another from the engine.
– Run commands SC002 Enter injector codes and SC036 Reintialise programming and follow the procedures.
– Restart the engine.
– If the injector concerned produces another combustion misfire in its new position, replace it.
If the fault is stored:
check that no customer complaint has been declared; clear the fault and carry out a road test.
If the fault is still present, apply test 10: Incorrect injector operation.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-102V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF060
CONTINUED
DF060 appears on the diagnostic tool when the engine management computer has detected a fault during the
combustion phase several times in succession.
Several components may be responsible:
– the piston rings,
– the piston,
– the valves,
– the injector,
– the heater plug sealing.
If the fault is present:
– remove the injector concerned,
– if there is no obvious fault in the way the injector has been fitted (notably the injector washer), swap the injector
with another from the engine.
– Run commands SC002 Enter injector codes and SC036 Reintialise programming and follow the procedures.
– Restart the engine.
– If the injector concerned produces another combustion misfire in its new position, replace it.
If the fault is stored:
check that no customer complaint has been declared; clear the fault and carry out a road test.
If the fault is still present, apply test 10: Incorrect injector operation.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-104V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF061
CONTINUED
DF061 appears on the diagnostic tool when the engine management computer has detected a fault during the
combustion phase several times in succession.
Several components may be responsible:
– the piston rings,
– the piston,
– the valves,
– the injector,
– the heater plug sealing.
If the fault is present:
– remove the injector concerned,
– if there is no obvious fault in the way the injector has been fitted (notably the injector washer), swap the injector
with another from the engine.
– Run commands SC002 Enter injector codes and SC036 Reintialise programming and follow the procedures.
– Restart the engine.
– If the injector concerned produces another combustion misfire in its new position, replace it.
If the fault is stored:
check that no customer complaint has been declared; clear the fault and carry out a road test.
If the fault is still present, apply test 10: Incorrect injector operation.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-106V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF062
CONTINUED
DF062 appears on the diagnostic tool when the engine management computer has detected a fault during the
combustion phase several times in succession.
Several components may be responsible:
– the piston rings,
– the piston,
– the valves,
– the injector,
– the heater plug sealing.
If the fault is present:
– remove the injector concerned,
– if there is no obvious fault in the way the injector has been fitted (notably the injector washer), swap the injector
with another from the engine.
– Run commands SC002 Enter injector codes and SC036 Reintialise programming and follow the procedures.
– Restart the engine.
– If the injector concerned produces another combustion misfire in its new position, replace it.
If the fault is stored:
check that no customer complaint has been declared; clear the fault and carry out a road test.
If the fault is still present, apply test 10: Incorrect injector operation.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58