13B-74
MR-372-J84-13B200$288.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF047
PRESENT
OR
STOREDCOMPUTER FEED VOLTAGE
1.DEF: Voltage outside permitted range of values
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after several starting attempts, or with the engine
running.
Special notes:
Computer operating voltage: 9 V < PR071 < 16 V.
Battery voltage that is too low can cause the level 1 fault warning light to come on
thereby causing other faults to appear.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Check the continuity and absence of interference resistance of the following connections:
– connection code AP15 between components 120 and 1337 (Scénic II et Mégane II).
– connection code AP29 between components 120 and 597 (Laguna II).
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the condition of the injection control unit supply relay (50A) located on a relay plate in the engine
compartment connection unit (no false contact or oxidation on the relay mounting clips).
Repair if necessary.
If the fault does not reappear, start the engine and wait 1 minute.
Carry out a road test and check the system faults.
If there are no faults, fault finding is complete.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF047/EDC16_V58_DF047/EDC16_V5C_DF047/EDC16_V18_DF047EDC16
Program No.: C1
Vdiag No.: 18, 50,
58, 5C
13B-77
MR-372-J84-13B200$288.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF050
PRESENT
OR
STOREDBRAKE SWITCH CIRCUIT
1.DEF: Open circuit or short circuit
2.DEF : Inconsistent signal
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the brake pedal is depressed, or during a road test.
Special notes:
If the fault is present, the cruise control/speed limiter is deactivated.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
1. DEF
NOTESNone
Check the brake pedal switch connections.
Check the condition and adjustment of the brake pedal switch.
Repair if necessary.
Check the conformity of the brake light switch:
For Mégane II and Scénic II without ESP:
Brake pedal released:
– continuity between connections 5A and BPT,
– infinite resistance between connections 65A and SP17.
Brake pedal depressed:
– infinite resistance between connections 5A and BPT,
– continuity between the connections 65A and SP17.
For Mégane II and Scénic II with ESP:
Brake pedal released:
– continuity between connections 5A and BPT,
– infinite resistance between connections 65G and SP17.
Brake pedal depressed:
– infinite resistance between connections 5A and BPT,
– continuity between the connections 65G and SP17.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF050/EDC16_V58_DF050/EDC16_V5C_DF050/EDC16_V18_DF050/EDC16_V1C_DF050/EDC16_V20_DF050EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B-80
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF053
PRESENT
OR
STORED
RAIL PRESSURE REGULATION FUNCTION
CC.1: Short circuit to + 12 V
CC.0: Short circuit to earth
CO: Open circuit
1.DEF: Internal electronic fault
2.DEF: Pressure measured too low
3.DEF: Pressure measured too high
4.DEF: Insufficient pressure
5.DEF: Pressure < minimum
6.DEF: Pressure > maximum
7.DEF: Significant pump control
8.DEF: Above maximum threshold
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test,
– an actuator command AC011 Rail pressure regulator.
Special notes:
If the fault is present:
– it is not possible to start the engine,
– engine stops if already started,
–if 3.DEF is present, the level 1 warning light is lit,
– if one of the other faults is present, the level 2 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
CC.1
NOTESNone
Check the rail pressure regulator connectors.
Check the injection computer connections.
Check the low pressure circuit by running test 3 Low pressure circuit check.
Check the conformity of the fuel used by running test 11 Diesel fuel conformity check.
Check the overpressure valve, run test 12 Incorrect operation of the overpressure valve,
Check the operation of the injectors, run test 9 Incorrect injector operation.
Repair if necessary.
Measure the resistance of the rail pressure regulator between connections 3HI and 3FB (Mégane II and
Laguna II) or 3FB1 (Scénic II).
Replace the injection pump if its resistance is not 3 ohms ± 1 at 20°C.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF053/EDC16_V58_DF053/EDC16_V5C_DF053/EDC16_V18_DF053/EDC16_V1C_DF053/EDC16_V20_DF053
13B-85
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF054
PRESENT
OR
STORED
TURBOCHARGING SOLENOID VALVE CONTROL CIRCUIT
CC.1: Short circuit to +12 V
CC.0: Short circuit to earth
CO: Open circuit
1.DEF: Internal electronic fault
2.DEF : Inconsistent signal
3.DEF: Below minimum threshold
4.DEF: Above maximum threshold
5.DEF: Permanent high signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the engine is started,
– a road test,
– actuator command AC004 Turbocharging solenoid valve.
Special notes:
If the fault is present:
– turbocharging is no longer authorised,
– the EGR function is inhibited,
– the vehicle performance is reduced,
– the level 1 warning light is lit,
–If CC.0 is present, the OBD warning light will come on after three consecutive
driving cycles (starting + 5 seconds, switch off the ignition and wait for 1 minute).
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF054/EDC16_V58_DF054/EDC16_V5C_DF054/EDC16_V18_DF054/EDC16_V1C_DF054/EDC16_V20_DF054
13B-88
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF055
PRESENT
OR
STOREDTURBOCHARGING PRESSURE REGULATION CIRCUIT
1.DEF: Pressure too low
2.DEF: Pressure too high
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– turbocharging is no longer authorised,
– the EGR function is inhibited,
– the level 1 warning light is illuminated.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF055/EDC16_V58_DF055/EDC16_V5C_DF055/EDC16_V18_DF055/EDC16_V1C_DF055/EDC16_V20_DF055
13B-91
MR-372-J84-13B200$288.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF056
PRESENT
OR
STOREDAIR FLOWMETER CIRCUIT
CC.1: Short circuit to + 12 V
CO.0: Open circuit or short circuit to earth
1.DEF: Offset at maximum threshold
2.DEF: Offset at minimum threshold
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Special notes:
If the fault is present:
– the level 1 warning light is lit,
– the OBD warning light illuminates after three consecutive driving cycles (starting
+ 5 seconds + switch off the ignition and wait 1 minute).
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Priorities when dealing with a number of faults:
Deal with fault DF013 Sensor supply voltage no. 3 first, if it is present or stored.
CC.1
NOTESNone
Check the air flowmeter connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and insulation from + 12 V of the following connections:
– connection code3DW,
– connection code NT (Laguna II),
– connection code 3DU (Mégane II and Scénic II),
– connection code3DV,
– connection code 3KJ.
between components 120 and 799.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the air flow sensor.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF056/EDC16_V58_DF056/EDC16_V5C_DF056/EDC16_V18_DF056/EDC16_V1C_DF056/EDC16_V20_DF056
13B-95
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF057
CONTINUED
Check the supply of the water detection sensor between connections 3FB and N.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If none of these checks reveal any faults:
– Replace the water detection sensor (see MR 395 (Laguna II), 370 (Scénic II) or 364 (Mégane II), Mechanical,
13A, Fuel supply).
– Clear the fault.
– Carry out a road test (speed > 12 mph (20 km/h) and engine speed > 1200 rpm) for more than 30 seconds
to confirm the repair.
Note:
If the level of water in the fuel filter unit is lower than the sensor electrodes, certain driving conditions (turns, hills)
may cause erratic illumination of the injection fault warning light.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
13B-101
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF069
PRESENT
OR
STOREDIMPACT DETECTED SIGNAL
1.DEF: Impact stored by the injection computer
NOTESConditions for applying the fault finding procedure to stored faults:
Only apply the interpretation of this fault if the fault is present and the vehicle will not
start.
Special notes:
The fault appears when the injection computer receives a frontal impact signal from
the Airbag computer via the multiplex network.
As soon as the injection computer receives this signal:
– engine operation is prohibited,
– the level 2 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
If the vehicle has been involved in an accident:
Carry out any necessary repairs,
– clear the fault,
– switch off the ignition,
–wait 1 minute,
– switch on the ignition.
If the fault does not reappear, end of fault finding procedure.
If the fault recurs, run fault finding on the AIRBAG computer.
If the vehicle has not been involved in an accident:
Run fault finding on the AIRBAG computer (see 88C, Airbag and pretensioner).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF069/EDC16_V58_DF069/EDC16_V5C_DF069/EDC16_V18_DF069/EDC16_V1C_DF069/EDC16_V20_DF069