Page 154 of 365
13B-154
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF778
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE REGULATION
1.DEF: Measured temperature too high
2.DEF: Parameter at maximum limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present if:
– the engine is started with a speed greater than 1750 rpm and a fuel flow greater
than 30 mg/st,,
– a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the vehicle performance is reduced,
–the level 1 warning light is lit.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF778/EDC16_V58_DF778/EDC16_V5C_DF778/EDC16_V18_DF778/EDC16_V1C_DF778/EDC16_V20_DF778
Page 155 of 365

13B-155
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF778
CONTINUED
Check the turbine upstream temperature sensor connections.
check the engine management computer connections.
If there is a repair procedure (see Technical Note 6015A, Electrical wiring repair, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check the continuity, absence of interference resistance and insulation against + 5 V and + 12 V of the
following connections:
– connection code 3ABS,
– connection code 3ABT.
Between components 120 and 1589.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity, absence of interference resistance and insulation to earth of connection 3ABS
between components 120 and 1589.
Check for earth on connection 3ABT of the turbine upstream temperature sensor.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Apply TEST 4 Turbocharged air inlet circuit check.
If the fault is still present, warm up the engine until parameter PR064 Coolant temperature = 80°C.
Run the engine at fast idle speed:
PR055 Engine speed = 1500 rpm for 2 minutes.
If PR667 Turbine upstream temperature remains fixed at 200°C, replace the turbine upstream temperature
sensor.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
Page 158 of 365

13B-158
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
*diff: differentialDF953
PRESENT
OR
STORED
PARTICLE FILTER ABSENT
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– blue/white smoke and black particles coming from the exhaust,
– the OBD warning light illuminates after three consecutive driving cycles (starting
+ 5 seconds + switch off the ignition and wait 1 minute).
Priorities when dealing with a number of faults:
Firstly, deal with the following faults:
–DF315 Particle filter diff* pressure sensor if it is present or stored.
–DF717 Particle filter upstream pressure if it is present or stored.
Use bornier Elé.1681 for all operations on the engine management computer
connector.
IMPORTANT
In the long term, this fault may lead to premature wear and a greater risk of
turbocharger failure.
Check the condition of the differential pressure sensor connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II or Laguna II, component code 1290).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II or Laguna II, component code 120).
If the connector(s) is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, wiring: Precautions for repair), repair the connector(s); otherwise, replace the wiring.
Check the particle filter is present.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF953/EDC16_V58_DF953/EDC16_V5C_DF953/EDC16_V18_DF953/EDC16_V1C_DF953/EDC16_V20_DF953
Page 160 of 365

13B-160
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF1070
PRESENT
OR
STOREDCOLD LOOP
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present with the engine running and a heating and air
conditioning request
Priorities when dealing with a number of faults:
Firstly, deal with the following faults:
–DF049 Refrigerant sensor circuit, if it is present or stored.
When the fault is present or stored, the heating and air conditioning system is inhibited.
Check fuse F22 (10A) of the UPC and the condition of the air conditioning compressor connector.
If the connectors is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the air conditioning compressor wiring.
If the wiring is faulty and there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Manually check if the compressor is jammed (turn the clutch plate manually to check that there is no point of
resistance). In the event of sticking, replace the air conditioning compressor (see MR 364 (Mégane II) or 370
(Scénic II), Mechanical, Heating and air conditioning system, 62A, Air conditioning, Compressor:
Removal – Refitting).
Top up with refrigerant, check for any leaks and repair if necessary (see MR 364 (Mégane II) or 370 (Scénic II),
Mechanical, Heating and air conditioning system, 62A, Air conditioning, Refrigerant circuit: check,
Refrigerant circuit: Draining – Filling).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF1070/EDC16_V58_DF1070/EDC16_V5C_DF1070/EDC16_V18_DF1070/EDC16_V1C_DF1070/EDC16_V20_DF1070
Page 162 of 365

13B-162
MR-372-J84-13B200$468.mif
V13
13B
DIESEL INJECTION
Fault finding – Status summary table
Tool status Diagnostic tool title
ET001+ After ignition computer feed
ET003Engine immobiliser
ET004Air conditioning authorisation
ET007Pre-postheating unit control
ET014Monitor cooling fan 1
ET015Monitor cooling fan 2
ET021High speed fan assembly request
ET022Low speed fan assembly request
ET038Engine
ET042Cruise control/speed limiter
ET076Starting
ET077Impact detected
ET079Air conditioning present
ET088Compressor actuation request
ET104Injector code use
ET111Number of passenger compartment heating resistors fixed (Vdiag 50 only)
ET112Passenger compartment heating resistors cut out (Vdiag 50 only)
ET143Low-speed fan assembly relay control (Vdiag 18, 1C, 20 only)
ET144High-speed fan assembly relay control (Vdiag 18, 1C, 20 only)
ET205Heating element no. 1 relay control (Vdiag 58 only)
ET206Heating element no. 2 relay control (Vdiag 58 only)
ET207Heating element no. 3 relay control (Vdiag 58 only)
ET238Synchronisation
ET341Immobiliser code programmed
ET405Clutch pedal switch
ET415Cruise control/speed limiter deactivation
ET651EGR programming cut-off
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
MR-372-J84-13B200$468.mif
Page 163 of 365

13B-163
MR-372-J84-13B200$468.mif
V13
DIESEL INJECTION
Fault finding – Status summary table
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
* regen.: regeneration Tool status Diagnostic tool title
ET703Cruise control/speed limiter button
ET704Brake switch No. 1
ET705Brake switch No. 2
ET706Stored engine status no. 1
ET707Stored engine status no. 2
ET708Stored engine status no. 3
ET709Stored engine status no. 4
ET710Stored engine status no. 5
ET711Stored engine status no. 6
ET712Stored engine status no. 7
ET713Stored engine status no. 8
ET714Stored engine status no. 9
ET715Stored engine status no. 10
ET742Stored regen.* request status No. 1
ET743Stored regen.* request status No. 2
ET744Stored regen.* request status No. 3
ET745Stored regen.* request status No. 4
ET746Stored regen.* request status No. 5
ET747Stored regen.* request status No. 6
ET748Stored regen.* request status No. 7
ET749Stored regen.* request status No. 8
ET750Stored regen.* request status No. 9
ET751Stored regen.* request status No. 10
Page 164 of 365

13B-164
MR-372-J84-13B200$504.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of statuses
ET001
COMPUTER + AFTER IGNITION FEED
STATUS DEFINITIONPRESENT, this status indicates that the + after ignition feed is active.
ABSENT, this status indicates that the + after ignition feed is inactive.
NOTESSpecial notes:
Only perform these tests if the statuses do not correspond with the system
programming functions.
Conformity check with the engine stopped and the ignition on, or engine running, and engine coolant
temperature > 80°C
PRESENT
With the ignition on and engine running warm at idle speed, + after ignition feed is
activated.
In the event of a fault, apply the interpretation of DF046 Battery voltage or DF151 Main
relay circuit.
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
EDC16_V18_ET001/EDC16_V1C_ET001/EDC16-V20_ET001/EDC16_V50_ET001/EDC16_V58_ET001/EDC16-V5C_ET001 EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
MR-372-J84-13B200$504.mif
Page 166 of 365
13B-166
MR-372-J84-13B200$504.mif
V13
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5CDIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET003
ENGINE IMMOBILISER
STATUS DEFINITIONACTIVE, this status indicates that the immobiliser is active.
INACTIVE, this status indicates that the immobiliser is inactive.
NOTESSpecial notes:
Only perform these tests if the statuses do not correspond with the system
programming functions.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant temperature
> 80°C
ACTIVE
Refer to the fault finding note for the UCH (see 87B, Passenger compartment
connection unit).
INACTIVERefer to the fault finding note for the UCH (see 87B, Passenger compartment
connection unit).
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_ET003/EDC16_V58_ET003/EDC16-V5C_ET003/EDC16_V18_ET003/EDC16_V1C_ET003/EDC16-V20_ET003