13B-96
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF058
PRESENT
OR
STOREDOIL TEMPERATURE SENSOR CIRCUIT
CO.1: Open circuit or short circuit to + 12 V
CC.0 : Short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine
running.
Special notes:
Use bornier Elé. 1681 or Elé. 1590 for all operations on the computer connectors.
This fault only occurs on vehicles with automatic transmission.
Check the oil temperature sensor connections.
Check the injection computer connections.
Repair if necessary.
Measure the resistance of the oil temperature sensor between connections 47Q and 115A.
Replace the oil temperature sensor if the resistance is not approximately:
11 50 Ω at 40°C
308 Ω at 80°C
105 Ω at 120°C
53 Ω at 150°C
Check the insulation, continuity and the absence of interference resistance of the following connections:
– connection code 47Q,
– connection code 115 A.
Between components 120 and 688.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the oil temperature sensor.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF058/EDC16_V58_DF058/EDC16_V5C_DF058/EDC16_V18_DF058/EDC16_V1C_DF058/EDC16_V20_DF058