2011 NISSAN TIIDA Top support

[x] Cancel search: Top support

Page 2040 of 3787

NISSAN TIIDA 2011  Service Repair Manual EC-746
< SERVICE INFORMATION >[MR18DE]
DTC P0139 HO2S2
1. Start engine and warm it up to normal operating temperature.
2. Select “SELF-LEARNING CONT” in 
“WORK SUPPORT” mode with CONSULT-III.

Page 2049 of 3787

NISSAN TIIDA 2011  Service Repair Manual DTC P014C, P014D A/F SENSOR 1EC-755
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
2. Listen for an exhaust gas leak before three way catalyst (manifold).
OK or NG
OK >> GO TO 4.
NG

Page 2099 of 3787

NISSAN TIIDA 2011  Service Repair Manual DTC P0420 THREE WAY CATALYST FUNCTIONEC-805
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
DTC P0420 THREE WAY CATALYST FUNCTION
On Board Diagnosis LogicINFOID:0000000006341971
The E

Page 2110 of 3787

NISSAN TIIDA 2011  Service Repair Manual EC-816
< SERVICE INFORMATION >[MR18DE]
DTC P0442 EVAP CONTROL SYSTEM
DTC Confirmation Procedure
INFOID:0000000006341982
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn i

Page 2161 of 3787

NISSAN TIIDA 2011  Service Repair Manual DTC P0455 EVAP CONTROL SYSTEMEC-867
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
NOTE:
•
Make sure that EVAP hose are connected to EVAP  canister purge volume control solenoid va

Page 2284 of 3787

NISSAN TIIDA 2011  Service Repair Manual EC-990
< SERVICE INFORMATION >[MR18DE]
DTC P2A00 A/F SENSOR 1
3. Turn ignition switch ON and select “SELF-LE
ARNING CONT” in “WORK SUPPORT” mode with CON-
SULT-III.
4.  Clear the self-learning

Page 2287 of 3787

NISSAN TIIDA 2011  Service Repair Manual DTC P2A00 A/F SENSOR 1EC-993
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4.CLEAR THE SELF-LEARNING DATA
  With CONSULT-III
1. Start engine and warm it up to normal operating tempe

Page 2289 of 3787

NISSAN TIIDA 2011  Service Repair Manual DTC P2A00 A/F SENSOR 1EC-995
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
1. Start engine and warm it up to normal operating temperature.
2. Select “SELF-LEARNING CONT” in “W