DLK-84
< DTC/CIRCUIT DIAGNOSIS >
B2401 IGNITION POWER SUPPLY CIRCUIT
B2401 IGNITION POWER SUPPLY CIRCUIT
DTC LogicINFOID:0000000006225878
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON and wait for at least 1 second.
2. Check “Self Diagnostic Result” mode of “AUTOMAT IC BACK DOOR CONTROL UNIT” using CONSULT-
III.
Is DTC detected?
YES >> Refer to DLK-84, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000006225879
1.CHECK FUSE
1. Turn ignition switch OFF.
2. Check 10A fuse, [No. 4, located in fuse block (J/B)].
Is the inspection result normal?
YES >> GO TO 2.
NO >> Replace the blown fuse after repairing the affected circuit if a fuse is blown.
2.CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect automatic back door control unit connector.
3. Check voltage between automatic back door control unit harness connector and ground.
Is the measurement value normal?
YES >> Check intermittent incident. Refer to GI-40, "Intermittent Incident".
NO >> Repair or replace harness.
DTC CONSULT-III display
description DTC detecting condition Possible cause
B2401 IGN OPEN When the automatic back door control unit detects
the following condition for 0.3 second or more
Power supply condition (OFF) of automatic back
door control unit and Ignition position signal (ON)
from BCM via CAN Fuse
Harness or connectors
(Ignition power supply condition
circuit is open or shorted)
(+)
(− ) Condition Vo l ta g e
(Approx.)
Automatic back door control unit
Connector Terminal
B26 9 Ground Ignition switch ON Battery voltage
OFF 0 V
Revision: 2010 May2011 QX56
DLK-86
< DTC/CIRCUIT DIAGNOSIS >
B2409 HALF LATCH SWITCH
B2409 HALF LATCH SWITCH
DTC LogicINFOID:0000000006225882
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check “Self Diagnostic Result” mode of “AUTOMAT IC BACK DOOR CONTROL UNIT” using CONSULT-
III.
Is DTC detected?
YES >> Refer to DLK-86, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000006225883
1.CHECK HALF LATCH SWITCH SIGNAL
1. Select “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-III.
2. Select “HALF LATCH SW” in “DATA MONITOR” mode.
3. Check that the function operates normall y according to the following conditions.
Is the inspection result normal?
YES >> GO TO 6.
NO >> GO TO 2.
2.CHECK HALF LATCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly connector.
3. Check voltage between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> GO TO 3.
3.CHECK HALF LATCH SWITCH CIRCUIT
1. Disconnect automatic back door control module connector.
2. Check continuity between automatic back door control module harness connector and back door lock
assembly harness connector.
DTC CONSULT-III display
description DTC detecting condition Possible cause
B2409 HALF LATCH SW When the automatic back door control unit can not
detects the half latch switch ON condition even
when the back door is in the open position Half latch switch
Harness or connectors
(Half latch switch circuit is open)
Automatic back door control mod-
ule
Monitor item Condition Status
HALF LATCH SW Back door Fully closed/Half latch OFF
Open ON
(+)
(–)Voltag e
(Approx.)
Back door lock assembly
Connector Terminal D157 6 Ground Battery voltage
Revision: 2010 May2011 QX56
B2409 HALF LATCH SWITCHDLK-87
< DTC/CIRCUIT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
DLK
N
O P
Is the inspection result normal?
YES >> Replace automatic back door control module. Refer to DLK-262, "Removal and Installation".
NO >> Repair or replace harness.
4.CHECK HALF LATCH SWITCH GROUND CIRCUIT
Check continuity between back door lo ck assembly harness connector and ground.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace back door lock assembly ground circuit.
5.CHECK HALF LATCH SWITCH
Refer to DLK-87, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Replace back door lock assembly.
6.CHECK INTERMITTENT INCIDENT
Refer to GI-40, "
Intermittent Incident".
>> INSPECTION END
Component InspectionINFOID:0000000006225884
COMPONENT INSPECTION
1.CHECK HALF LATCH SWITCH
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly.
3. Check continuity between back door lock assembly terminals.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace back door lock assembly.
Automatic back door control module Back door lock assembly Continuity
Connector Terminal Connector Terminal
B26 8 D157 6 Existed
Back door lock assembly GroundContinuity
Connector Terminal
D157 8 Existed
Back door lock assembly Condition Continuity
Te r m i n a l
6 8 Back door lock Open Existed
Fully closed/Half latch Not existed
Revision: 2010 May2011 QX56
DLK-92
< DTC/CIRCUIT DIAGNOSIS >
B2419 OPEN SWITCH
B2419 OPEN SWITCH
DTC LogicINFOID:0000000006225891
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check “Self Diagnostic Result” mode of “AUTOMAT IC BACK DOOR CONTROL UNIT” using CONSULT-
III.
Is DTC detected?
YES >> Refer to DLK-92, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000006225892
1.CHECK OPEN SWITCH SIGNAL
1. Select “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-III.
2. Select “OPEN SW” in “DATA MONITOR” mode.
3. Check that the function operates normall y according to the following conditions.
Is the inspection result normal?
YES >> GO TO 6.
NO >> GO TO 2.
2.CHECK AUTOMATIC BACK DOOR CONTROL MODULE OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly connector.
3. Check voltage between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> GO TO 3.
DTC CONSULT-III display
description DTC detecting condition Possible cause
B2419 OPEN SW When the automatic back door control unit detects
any of the following conditions
The change of open switch cannot be detected
for 1 second or more after starting the closure
open output for the 3rd time in a row
The change of open switch cannot be detected for 0.5 second or more after starting the closure
close output for the 3rd time in a row
The condition that the open switch is in the ON position and the close switch is in the OFF posi-
tion is detected when starting the closure open/
close output for the 3rd time in a row Open switch
Harness or connectors
(Open switch circuit is open or
shorted)
Automatic back door control mod- ule
Monitor item Condition Status
OPEN SW Back door Fully closed/Half latch OFF
Open ON
(+)
(–)Voltag e
(Approx.)
Back door lock assembly
Connector Terminal D157 4 Ground Battery voltage
Revision: 2010 May2011 QX56
B2419 OPEN SWITCHDLK-93
< DTC/CIRCUIT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
DLK
N
O P
3.CHECK OPEN SWITCH CIRCUIT
1. Disconnect automatic back door control module connector.
2. Check continuity between automatic back door control module harness connector and back door lock
assembly harness connector.
3. Check continuity between automatic back door control module harness connector and ground.
Is the inspection result normal?
YES >> Replace automatic back door control module. Refer to DLK-262, "Removal and Installation".
NO >> Repair or replace harness.
4.CHECK OPEN SWITCH GROUND CIRCUIT
Check continuity between back door lo ck assembly harness connector and ground.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace harness.
5.CHECK OPEN SWITCH
Refer to DLK-93, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Replace back door lock assembly.
6.CHECK INTERMITTENT INCIDENT
Refer to GI-40, "
Intermittent Incident".
>> INSPECTION END
Component InspectionINFOID:0000000006225893
COMPONENT INSPECTION
1.CHECK OPEN SWITCH
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly connector.
3. Check continuity between back door lock assembly terminals.
Is the inspection result normal?
YES >> INSPECTION END
Automatic back door control module Back door lock assembly Continuity
Connector Terminal Connector Terminal
B26 20 D157 4 Existed
Automatic back door control module GroundContinuity
Connector Terminal
B26 20 Not existed
Back door lock assembly GroundContinuity
Connector Terminal
D157 8 Existed
Back door lock assembly Condition Continuity
Te r m i n a l
4 8 Back door Open Existed
Fully closed/Half latch Not existed
Revision: 2010 May2011 QX56
DLK-94
< DTC/CIRCUIT DIAGNOSIS >
B2419 OPEN SWITCH
NO >> Replace back door lock assembly.
Revision: 2010 May2011 QX56
B2420 CLOSE SWITCHDLK-95
< DTC/CIRCUIT DIAGNOSIS >
C
DE
F
G H
I
J
L
M A
B
DLK
N
O P
B2420 CLOSE SWITCH
DTC LogicINFOID:0000000006225894
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check “Self Diagnostic Result” mode of “AUTOMAT IC BACK DOOR CONTROL UNIT” using CONSULT-
III.
Is DTC detected?
YES >> Refer to DLK-95, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000006225895
1.CHECK CLOSE SWITCH SIGNAL
1. Select “AUTOMATIC BACK DOOR CONTROL UNIT” using CONSULT-III.
2. Select “CLOSE SW” in “DATA MONITOR” mode.
3. Check that the function operates normall y according to the following conditions.
Is the inspection result normal?
YES >> GO TO 6.
NO >> GO TO 2.
2.CHECK AUTOMATIC BACK DOOR CONTROL MODULE OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly connector.
3. Check voltage between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> GO TO 3.
3.CHECK CLOSE SWITCH CIRCUIT
1. Disconnect automatic back door control module connector.
2. Check continuity between automatic back door control module harness connector and back door lock
assembly harness connector.
DTC CONSULT-III display
description DTC detecting condition Possible cause
B2420 CLOSE SW When the automatic back door control unit detects
any of the following conditions
The change of close switch cannot be detected
for 3 second or more after starting the closure
close output for the 3rd time in a row Close switch
Harness or connectors
(Close switch circuit is open or
shorted)
Automatic back door control mod- ule
Monitor item Condition Status
CLOSE SW Back door Open/Half latch OFF
Fully closed ON
(+)
(–)Voltag e
(Approx.)
Back door lock assembly
Connector Terminal D157 5 Ground Battery voltage
Revision: 2010 May2011 QX56
DLK-96
< DTC/CIRCUIT DIAGNOSIS >
B2420 CLOSE SWITCH
3. Check continuity between automatic back door control module harness connector and ground.
Is the inspection result normal?
YES >> Replace automatic back door control module. Refer to DLK-262, "Removal and Installation".
NO >> Repair or replace harness.
4.CHECK CLOSE SWITCH GROUND CIRCUIT
Check continuity between back door lock assembly harness connector and ground.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace harness.
5.CHECK CLOSE SWITCH
Refer to DLK-95, "
Diagnosis Procedure".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Replace back door lock assembly.
6.CHECK INTERMITTENT INCIDENT
Refer to GI-40, "
Intermittent Incident".
>> INSPECTION END
Component InspectionINFOID:0000000006225896
COMPONENT INSPECTION
1.CHECK CLOSE SWITCH
1. Turn ignition switch OFF.
2. Disconnect back door lock assembly.
3. Check continuity between back door lock assembly terminals.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace back door lock assembly.
Automatic back door control module Back door lock assembly Continuity
Connector Terminal Connector Terminal
B26 19 D157 5 Existed
Automatic back door control module GroundContinuity
Connector Terminal
B26 19 Not existed
Back door lock assembly GroundContinuity
Connector Terminal
D157 8 Existed
Back door lock assembly Condition Continuity
Te r m i n a l
5 8 Back door Fully closed Existed
Open/Half latch Not existed
Revision: 2010 May2011 QX56