Page 4110 of 5598
POWER WINDOW SYSTEMPWC-25
< WIRING DIAGRAM >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
JCKWM4476GB
Revision: 2010 May2011 QX56
Page 4111 of 5598
PWC-26
< WIRING DIAGRAM >
POWER WINDOW SYSTEM
JCKWM4477GB
Revision: 2010 May2011 QX56
Page 4112 of 5598
POWER WINDOW SYSTEMPWC-27
< WIRING DIAGRAM >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
JCKWM4478GB
Revision: 2010 May2011 QX56
Page 4113 of 5598
PWC-28
< WIRING DIAGRAM >
POWER WINDOW SYSTEM
JCKWM4479GB
Revision: 2010 May2011 QX56
Page 4114 of 5598
POWER WINDOW SYSTEMPWC-29
< WIRING DIAGRAM >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
JCKWM4480GB
Revision: 2010 May2011 QX56
Page 4116 of 5598
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL
PWC-31
< BASIC INSPECTION >
C
D E
F
G H
I
J
L
M A
B
PWC
N
O P
ADDITIONAL SERVICE WHEN REMO VING BATTERY NEGATIVE TERMI-
NAL
DescriptionINFOID:0000000006274848
When the battery negative terminal is disconnected, the initialization is necessary for normal operation of
power window system.
CAUTION:
The following specified operations can not be performed under the non-initialized condition.
Auto-up operation
Anti-pinch function
Work ProcedureINFOID:0000000006217283
1.SYSTEM INITIALIZATION
Perform system initialization. Refer to PWC-33, "
Work Procedure".
>> GO TO 2.
2.CHECK ANTI-PINCH FUNCTION
Check anti-pinch function. Refer to PWC-34, "
Work Procedure".
>> END
Revision: 2010 May2011 QX56
Page 4117 of 5598
PWC-32
< BASIC INSPECTION >
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT
DescriptionINFOID:0000000006274849
When the control unit replaced, the initialization in necessary for normal operation of power window system.
CAUTION:
The following specified operations can not be performed under the non-initialized condition.
Auto-up operation
Anti-pinch function
Work ProcedureINFOID:0000000006217285
1.SYSTEM INITIALIZATION
Perform system initialization. Refer to PWC-33, "
Work Procedure".
>> GO TO 2.
2.CHECK ANTI-PINCH FUNCTION
Check anti-pinch function. Refer to PWC-34, "
Work Procedure".
>> END
Revision: 2010 May2011 QX56
Page 4118 of 5598

SYSTEM INITIALIZATIONPWC-33
< BASIC INSPECTION >
C
DE
F
G H
I
J
L
M A
B
PWC
N
O P
SYSTEM INITIALIZATION
DescriptionINFOID:0000000006274850
If any of the following operations are performed, the in itialization is necessary for normal operation of power
window system.
When control unit replaced.
Electric power supply to power window switch or motor is interrupted by blown fuse or disconnection and
connection of the negative terminal of battery, etc.
Removal and installation of regulator assembly.
Power supply to the power window main switch or power window motor is cut off by the removal
of battery terminal or if the battery fuse is blown.
Disconnection and connection of power window main switch harness connector.
Removal and installation of motor from regulator assembly.
Operation of regulator assembly as an independent unit.
Removal and installation of door glass.
Removal and installation of door glass run.
The following specified operations can not be performed under the non-initialized condition.
Auto-up operation
Anti-pinch function
Work ProcedureINFOID:0000000006274851
1.STEP 1
1. Turn ignition switch ON.
2. Operate power window switch to fully open the wi ndow. (This operation is unnecessary if the window is
already fully open)
3. Continue pulling the power window switch UP (AUTO-UP operation). Even after glass stops at fully closed
position, keep pulling the switch for 2 seconds or more.
4. Check that AUTO-UP function operates normally.
>> GO TO 2.
2.STEP 2
Check anti-pinch function. Refer to PWC-34, "
Work Procedure".
>> END
Revision: 2010 May2011 QX56