PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-105
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-105V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF455
PRESENT
OR
STOREDLOW FUEL LEVEL SIGNAL
1.DEF: Multiplex network
2.DEF: Non-compliance with emission control standards
NOTESNone.
Run a multiplex network test (see88B, Multiplexing).
If the fault is still present, carry out fault finding on the Instrument panel system (see83A, Instrument panel).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF455/S3000_V54_DF455