PETROL INJECTION
Fault finding - Introduction
17B
17B-2
PETROL INJECTION
Fault finding - Introduction
17B
17B-2V9 MR-372-J84-17B050$047.mif
117B
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54PETROL INJECTION
Fault finding - Introduction
1. SCOPE OF THIS DOCUMENT
This document presents the fault finding procedure applicable to all computers with the following specifications:
2. PREREQUISITES FOR FAULT FINDING
Documentation type
Fault finding procedures (this document):
– Assisted fault finding (integrated into the diagnostic tool), Dialogys.
Wiring Diagrams:
– Visu-Schéma (CD-ROM), paper.
Type of diagnostic tools
–CLIP + multiplex line sensor
Special tooling required
3. REMINDERS
Procedure
To run fault finding on the vehicle's computers, switch on the ignition in fault finding mode (forced + after ignition
feed).
Proceed as follows:
– vehicle card in reader,
– press and hold the Start button (longer than 5 seconds) with start-up conditions not fulfilled,
– connect the diagnostic tool and perform the required operations.
To cut off the + after ignition feed, proceed as follows:
– disconnect the diagnostic tool,
– press the Start button twice briefly (less than 3 seconds),
– ensure that the + after ignition feed has been cut off by checking that the computer indicator lights on the instrument
panel have gone out. Vehicle(s):MEGANE II phase 2
SCENIC II phase 2
Engines:K4J 740 - K4M 766/812/813 - K4M 680 -
K4M 788 LPG
F4R 770/771 - F4R-T 776
F4R-T 774 (MEGANE II phase 2
RENAULT SPORT)
Function concerned: Petrol injectionName of computer: Sagem S3000
Program no.: AD
Vdiag No.: 4C, 54
Special tooling required
Multimeter
Ele. 1497Bornier
Elé. 1681Universal bornier
S3000_V4C_PRELI/S3000_V54_PRELI
MR-372-J84-17B050$047.mif
PETROL INJECTION
Fault finding - System operation
17B
17B - 19
PETROL INJECTION
Fault finding - System operation
17B
17B - 19V9 MR-372-J84-17B050$094.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
Camshaft dephaser:
The camshaft dephaser ET083 Camshaft dephaser in defect mode may assume two different statuses.
●Status 1
This defect mode covers all faults that affect the dephaser position measurement. The dephaser is set to the
minimum stop and the camshaft angle measurement is forced to 0.
Tooth signal fault.
Tooth/camshaft signal consistency diagnostic.
●Status 2
This defect mode covers all faults affecting the dephaser (pulley and solenoid valve). The dephaser is set to
the minimum stop.
Electrical fault finding on the solenoid valve.
Dephaser position fault finding procedure.
7. Operational safety
Warning lights illumination
The S3000 Injection system manages the illumination of three warning lights and the display of warning messages
according to the severity of the faults detected, with the aim of informing the customer and guiding fault finding.
The injection computer manages the illumination of warning lights and warning messages displayed on the instrument
panel. These warning lights illuminate during the starting phase and in the event of an injection fault or engine
overheating.
The warning light illumination signals reach the instrument panel via the multiplex network.
Warning light illumination principle
During the starting phase (START button pressed) the OBD (On Board Diagnostic) warning light comes on for
approximately 3 seconds then goes out.
If there is an injection fault (level 1), the message CHECK INJECTION is lit, followed by the SERVICE warning light.
It indicates a reduced level of operation and a limited safety level.
The driver should carry out repairs as soon as possible.
Components involved:
– motorised throttle valve,
– accelerator pedal potentiometer,
– inlet manifold pressure sensor,
– computer,
– actuator feed,
– computer feed.
If there is a serious injection fault (level 2), the red engine symbol and the word STOP (display with information
display only), appears with the message ENGINE OVERHEATING followed by the STOP warning light and a
buzzer. If this happens, the vehicle must be stopped immediately.
When a fault causing excessive pollution in the exhaust gases is detected, the orange OBD warning light engine
symbol is lit:
–flashing in the event of a fault which might cause destruction of the catalytic converter (destructive misfires). If this
happens, the vehicle must be stopped immediately.
–constantly in the case of non-compliance with the anti-pollution standards (polluting misfires, catalytic converter
fault, oxygen sensor faults, inconsistency between the oxygen sensors and canister fault).
PETROL INJECTION
Fault finding - Replacement of components
17B
17B-26
PETROL INJECTION
Fault finding - Replacement of components
17B
17B-26V9 MR-372-J84-17B050$188.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54PETROL INJECTION
Fault finding - Replacement of components
1. COMPUTER REPLACEMENT OR REPROGRAMMING OPERATIONS
The system can be programmed and reprogrammed via the diagnostic socket using the RENAULT CLIP diagnostic
tool (Consult Technical Note 3585A or follow the instructions provided by the diagnostic tool).
Whenever the computer has been programmed, reprogrammed or replaced:
–Switch off the ignition.
–Start and then stop the engine (to initialise the computer) and wait 30 seconds.
–Switch the ignition back on and use the diagnostic tool to carry out the following steps:
– use command VP020 Enter VIN.
– deal with any faults declared by the diagnostic tool. Clear the computer memory.
– program the flywheel sensor target and throttle stops,
– carry out a road test followed by another check with the diagnostic tool. IMPORTANT
–Switch on the diagnostic tool (mains or cigarette lighter supply).
–Connect a battery charger (during the entire computer (re)programming procedure, the engine fan
assemblies are triggered automatically).
–Observe the engine temperature setpoints given on the diagnostic tool before (re)programming.
–Cut off all the electrical consumers (interior lighting, air conditioning, radio, etc.).
Operations to be carried out before the injection computer is reprogrammed:
Before reprogramming the injection computer, move the main Cruise control/Speed limiter switch to the rest
position. The information about the cruise control or the speed limiter displayed on the instrument panel
disappears.
Otherwise, if the main switch remains in the cruise control or speed limiter position during and after reprogramming,
the Cruise control/Speed limiter function will not be operational.
The procedure for resetting the function is as follows:
Vehicle ignition on.
– Position the main switch in rest position (the computer then detects the rest position).
– Position the switch in Cruise control position to activate the Cruise control function.
– Position the switch in Speed limiter position to activate the Speed limiter function.
IMPORTANT
It is not possible to try an injection computer coming from the Parts Department because it will no longer be
possible to use it on another vehicle.
MR-372-J84-17B050$188.mif
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-39
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-39V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF012
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE No. 2
1.DEF: Abnormal voltage
2.DEF: Fault on potentiometer supply 2
NOTESSpecial note:
–level 1 fault warning light illuminated.
– throttle valve defect mode types 4 and 5: vehicle and engine speed restriction, ESP
and the Cruise control/Speed limiter are deactivated.
Check the cleanliness and condition of the throttle valve connections.
Check the cleanliness and condition of the pedal potentiometer connections.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Repair if necessary.
Sensor feed no. 2 is reserved for the following components:
– pedal potentiometer gang 1,
– motorised throttle potentiometer gangs 1 and 2.
To locate any internal fault on one of the sensors with a 5V supply (short circuit), disconnect each of the sensors
on the list above in turn, checking after each disconnection whether the fault changes status from present to stored.
If the faulty sensor is located, check its connections and that it is in order.
Replace the faulty sensor if necessary.
Use the "Universal bornier" to check the insulation and continuity of the following connections:
Injection computer, connectorA, track G2 track 3 of the pedal potentiometer gang 1
Injection computer, connectorB, track G2 track 2 of the motorised throttle valve
(K4M 766/812 and 813, F4R 770 and 771)
track 5 of the motorised throttle valve
(K4J 740, K4M 788 LPG, F4RT 774 and 776)
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF012/S3000_V54_DF012
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-40
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-40V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF026
PRESENT
OR
STOREDCYLINDER 1 INJECTOR CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 1, severe deterioration in
performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 1 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 1 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of cylinder 1 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF026/S3000_V54_DF026
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-42
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-42V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF027
PRESENT
OR
STOREDCYLINDER 2 INJECTOR CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 2 and marked loss of performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 2 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 2 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of cylinder 2 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF027/S3000_V54_DF027
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-44
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-44V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF028
PRESENT
OR
STOREDCYLINDER 3 INJECTOR CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESOrder of priority in the event of more than one fault:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 3, severe deterioration in
performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 3 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 3 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of cylinder 3 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF028/S3000_V54_DF028
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-46
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-46V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF029
PRESENT
OR
STOREDINJECTOR CYLINDER 4 CONTROL CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESOrder of priority in the event of more than one fault:
Deal with faults DF084 Actuator relay control circuit or DF046 Battery voltage first
if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been running for a timed period of
10 seconds.
Special note:
–OBD warning light illuminated.
CO
CC.1
NOTESSpecial note:
No injection on cylinder 4, severe deterioration in
performance.
CC.0Special note:
The injector is always open: risk of stalling and damage to
the engine on starting, severe deterioration in performance.
Check the cleanliness and condition of the cylinder 4 injector and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on track 1 of the cylinder 4 injector connector.
If there is no + 12 V feed, use the "universal bornier" to check the continuity of the following connections:
Injection computer, connectorB, track M2 track 1 of the cylinder 4 injector
Protection and Switching Unit, connector CN,
track 6
Repair if necessary.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF029/S3000_V54_DF029