2010 NISSAN TIIDA ignition

[x] Cancel search: ignition

Page 2076 of 3745

NISSAN TIIDA 2010  Service Repair Manual DTC P0441 EVAP CONTROL SYSTEMEC-811
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wai

Page 2077 of 3745

NISSAN TIIDA 2010  Service Repair Manual EC-812
< SERVICE INFORMATION >[MR18DE]
DTC P0441 EVAP CONTROL SYSTEM
 
With CONSULT-III
1. Disconnect vacuum hose connected to EVAP canister  purge volume control solenoid valve at EVAP ser-
vice port

Page 2081 of 3745

NISSAN TIIDA 2010  Service Repair Manual EC-816
< SERVICE INFORMATION >[MR18DE]
DTC P0442 EVAP CONTROL SYSTEM
DTC Confirmation Procedure
INFOID:0000000005532664
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn i

Page 2082 of 3745

NISSAN TIIDA 2010  Service Repair Manual DTC P0442 EVAP CONTROL SYSTEMEC-817
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
OK or NG
OK >> GO TO 3.
NG >> 1. Open fuel filler cap, then clean cap and fuel filler neck threads

Page 2083 of 3745

NISSAN TIIDA 2010  Service Repair Manual EC-818
< SERVICE INFORMATION >[MR18DE]
DTC P0442 EVAP CONTROL SYSTEM
4. Using EVAP leak detector, locate the EVAP leak. For the leak
detector, refer to the instruction manual for more details.
Refer t

Page 2088 of 3745

NISSAN TIIDA 2010  Service Repair Manual DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-823
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
On Board Diagnosis LogicINFOID:0000000005532669
DTC Confirmation Pro

Page 2089 of 3745

NISSAN TIIDA 2010  Service Repair Manual EC-824
< SERVICE INFORMATION >[MR18DE]
DTC P0443 EVAP CANISTER PURGE VO
LUME CONTROL SOLENOID VALVE
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait

Page 2091 of 3745

NISSAN TIIDA 2010  Service Repair Manual EC-826
< SERVICE INFORMATION >[MR18DE]
DTC P0443 EVAP CANISTER PURGE VO
LUME CONTROL SOLENOID VALVE
Do not use ECM ground terminals when measuring input/output voltage. Doi ng so may result in dam-
ag