83A-65
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 6
CONTINUED 2
Measure the resistance of the sender and the wiring via the
connector, on the instrument panel side.
Is the value measured and the value provided by the CLIP
tool the same as or approximately ± 5 ΩΩ Ω Ω
?Contact the Techline.
Replace the instrument panel, component code 247 (see MR
411, Mechanical, 83A, Instrument panel, Instrument
panel: Removal - Refitting).
Is the fault still present?The problem disappears.
Contact the Techline.
E
YES
YES
NO
NO
YES
83A-66
AFTER REPAIRRepeat the conformity check from the start.
V5 MR-413-X44-83A000$952.mif
INSTRUMENT PANEL
Fault finding - Fault finding chart Vdiag No.: 04, 0883A
Vdiag No.: 04 08
ALP 7 Fault with delayed warning
NOTESOnly consult this customer complaint after a full check with the diagnostic tool.
Ask the customer the distance travelled since the
warning appeared until the fault occurred.
Did the fault take place after travelling more than
30 miles (50 Kms)?Explain to the customer that the guaranteed
distance is 30 miles (50 kms) from the
warning.
Has the customer added any fuel since the fault?See ALP6 Fault with no warning given
by warning light (addition of fuel since
the fault).
See ALP5 Fault with no warning given by
warning light (no addition of fuel since the fault).
YES
NO
YES
NO
TDB_V04_ALP7/TDB_V08_ALP7