AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 33V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
If the fault is stored:DF067
PRESENT
OR
STORED
LEVER POSITION SWITCH CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after:
–in the event of open circuit or short circuit-:
–+ after ignition feed and change of lever position.
–in the event of short circuit+:
–+ after ignition feed, initial lever position: Position "P", "R", "N" or "D".
Effect on system:
The lever value is held at its previous valid position until the fault is confirmed. Then
the lever position becomes DRIVE (internal software variable) irrespective of the fault.
–If the fault is present and the lever in position "P", the transmission is in "N", hydraulic
neutral.
–If the fault is present and the lever in position "R", the transmission is in "R", hydraulic
reverse.
–If the fault is present and the lever in position "N", the transmission is in "N", hydraulic
neutral.
–If the fault is present and the lever in position "D", the transmission is in "D", hydraulic
forward gear.
lock-up is inhibited.
Customer complaint:
No lever position display on the instrument panel following fault confirmation and
starting impossible.
If the engine is already running when the fault occurs, there is jolting when shifting from
"P" or "N" to "R" or "D".
Fault warning light comes on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Note:
It is possible to produce this fault if the driver or operator voluntarily keep the lever between two normal positions
for longer than 2 seconds.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF067/AJ0_V05_DF067
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 41V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF086
PRESENT
OR
STOREDEVS2 SEQUENCE SOLENOID VALVE CIRCUIT
CO.1: Short circuit or open circuit to + 12 V
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after:
–in the event of short circuit+:
Lever in "Drive" position, gear engaged = 2, 3, 4, 5, 6,
and Inconsistency between the solenoid valve control status and the control voltage.
–in the event of open circuit:
Lever in "Drive" position, lock-up closed, gear engaged = 2, 3, 4, 5, 6,
and Inconsistency between the solenoid valve control status and the control voltage.
–in the event of short circuit-:
Lever in "Drive" position, lock-up open, gear engaged = 1, 2, 3, 4, 5, 6,
OR Gear 1 with engine braking,
and Inconsistency between the solenoid valve control status and the control voltage.
OR
Running command AC002 "Shift solenoid 2".
Effect on system:
–in the event of short circuit+:
If the fault appears with the lock-up closed, gear engaged in "Drive" position = 2, 3, 4,
5, 6, automatic transmission is locked.
–in the event of open circuit:
No effect.
–in the event of short circuit-:
Risk of stalling in 1st with engine braking.
Customer complaint:
If the fault occurs while driving, the transmission engages fixed 5th gear.
Restarting is in 3rd gear.
Fault warning light comes on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the harness and check the condition and connection of the automatic transmission
computer and automatic transmission connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
If + after ignition feed is present, move on to step 1.
If + after ignition feed is not present, move on to step 8.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF086/AJ0_V05_DF086
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 45V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF091
PRESENT
OR
STORED"LS" PRESSURE REGULATION SOLENOID VALVE CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after:
–in the event of short circuit+ or short circuit-:
difference between current measured and solenoid valve control.
–in the event of open circuit:
Current setpoint > 625 mA.
OR
Running command AC086 ""LS" pressure regulation solenoid valve".
Effect on system:
–in the event of short circuit+:
The line pressure is at its minimum value.
lock-up open.
–in the event of open circuit:
No effect
–in the event of short circuit-:
The line pressure is at its maximum value.
Customer complaint:
–in the event of short circuit+:
Fault warning light comes on.
–in the event of open circuit or short circuit-:
Possible increase in fuel consumption.
Possible jolting during gear changes.
Fault warning light comes on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the harness and check the condition and connection of the automatic transmission
computer and automatic transmission connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
If + after ignition feed is present, move on to step 1.
If + after ignition feed is not present, move on to step 8.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF091//AJ0_V05_DF091
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 50V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF095
PRESENT
OR
STOREDSELECTOR LEVER LOCK ELECTROMAGNET CIRCUIT
1.DEF: Open circuit or short circuit
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after:
Lever in position "P" (without pressing the brake pedal), "R", "N", "D" or "M".
Customer complaint:
–in the event of open circuit or short circuit+:
The shift-lock solenoid valve cannot be activated: therefore the lever is placed in
position "P", blocking it. Unlocking is a manual operation.
–in the event of a CCM:
The shift-lock solenoid valve is always activated: therefore, no locking of lever.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
Look for any damage to the harness and check the condition and connection of the connectors on the automatic
transmission computer and on the shift pattern control.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection AP* of component 129.
Check for earth on connection N+ of component 129.
Check the insulation to earth and continuity of the following connection:
●Connection code 5DU, between components 119 and 129.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
In the event of a fault, replace the shift pattern control.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF095/AJ0_V05_DF095
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 51V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
*EVS2 = sequence solenoid valve 2DF097
PRESENT
OR
STORED
CONVERTER lock-up
1.DEF: CONVERTER LOCK-UP CONTROL
NOTESOrder of priority in the event of more than one fault:
If there is a combination of the following faults:
–DF097 "Converter lock-up",
–DF086 "Sequence solenoid valve circuit "EVS2*""
–DF306 "Lock-up/brake 1 solenoid valve circuit",
deal first with faults DF086 "Sequence solenoid valve "EVS2*"" and DF306 "Lock-
up/brake 1 solenoid valve circuit".
Conditions for applying fault finding procedures to stored faults:
The fault is declared present after:
If in lock-up:
Lever in Manual position,
and difference in *slippage speed ≥ 40 + Vehicle speed / 2 for a certain time,
and EVS2* solenoid valve control status > 95 %.
In the event of slippage:
Lever in Manual position,
and difference in slippage speed ≥ 40 + slippage speed setpoint for a certain time,
and EVS2* solenoid valve control status > 95 %.
*slippage = engine speed - turbine speed
Effect on system:
Increase in oil temperature.
–In the event of engagement fault, lock-up inhibited.
–In the event of slippage fault, lock-up slippage inhibited.
Customer complaint:
Warning light on.
Use the Wiring Diagrams Technical Note, SCENIC II ph2.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AJ0_V04_DF097/AJ0_V05_DF097
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 54V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
Fault finding on lock-up/brake solenoid valve 1: DF097
CONTINUED 3
Stage 6:
Disconnect the connector from sequence solenoid valve 2, measure the resistance of sequence solenoid
valve 2 between the following connections:
●Connection code 5CY.
●Connection code 5LW.
The resistance must be 28 ΩΩ Ω Ω
± 2.8 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 7.
If NOT, replace the hydraulic distributor.
Step 7:
Measure the continuity and insulation of the following connections:
●Connection code 5CY.
●Connection code 5LW.
Between sequence solenoid valve 2 and the internal connector on the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the internal wiring harness on the automatic transmission.
Step 8:
Check the continuity and insulation of the following connection:
●Connection code 5LW between components 119 and 754.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If + after ignition feed is not present after checking feeds and computer earths on the transmission, contact the
Techline.
Look for any damage to the harness and check the condition and connection of the automatic transmission
computer and on the automatic transmission connectors.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + after ignition feed on connection 5LW of component 754.
If + after ignition feed is present, move on to step 1.
If + after ignition feed is not present, move on to step 8.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 55V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF097
CONTINUED 4
Step 1:
Disconnect the connector from component 119, measure the resistance of the lock-up/brake solenoid valve
(on the connector of component 119) between the following connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, contact the Techline.
If NO, move on to step 2.
Step 2:
Disconnect connector R22 and check continuity and insulation of the following connections:
●Connection code 5BF.
●Connection code 5LW.
Between components 119 and R22.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, move on to step 3.
If NO, replace the external wiring harness on the automatic transmission.
Stage 3:
Measure the resistance of lock-up/brake 1 solenoid valve (on connector R22) between the following
connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 4.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 56V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF097
CONTINUED 5
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change) and
remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of lock-up/brake 1 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5BF.
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
Stage 6:
Disconnect the connector from lock-up/brake 1 solenoid valve, measure the resistance of lock-up/brake 1
solenoid valve between the following connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 7.
If NO, replace the hydraulic distributor.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.