AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 56V3 MR-372-J84-23A000$405.mif
AJ0 BVA
Vdiag No.: 04, 05
DF097
CONTINUED 5
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change) and
remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of lock-up/brake 1 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5BF.
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
Stage 6:
Disconnect the connector from lock-up/brake 1 solenoid valve, measure the resistance of lock-up/brake 1
solenoid valve between the following connections:
●Connection code 5BF.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 7.
If NO, replace the hydraulic distributor.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 73V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF273
CONTINUED 2
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change)
and remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of clutch 1 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5DL.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5DL.
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
Stage 6:
Disconnect the connector from clutch 1 solenoid valve, measure the resistance of clutch 1 solenoid valve
between the following connections:
●Connection code 5DL.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 7.
If NO, replace the hydraulic distributor.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 77V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF274
CONTINUED 2
Stage 3:
Measure the resistance of clutch 2 solenoid valve (on connector R22) between the following connections:
●Connection code 5DM.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 4.
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change)
and remove the transmission housing (see, MR370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of clutch 2 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5DM.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5DM.
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 81V3 MR-372-J84-23A000$450.mif
AJ0 BVA
Vdiag No.: 04, 05
DF275
CONTINUED 2
Stage 3:
Measure the resistance of clutch 2 solenoid valve (on connector R22) between the following connections:
●Connection code 5Q.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 4.
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change)
and remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of clutch 3 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5Q.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5Q.
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 90V3 MR-372-J84-23A000$495.mif
AJ0 BVA
Vdiag No.: 04, 05
DF300
CONTINUED 2
Stage 3:
Measure the resistance of brake 2 solenoid valve (on connector R22) between the following connections:
●Connection code 5R.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, and if the fault is still present, contact the Techline.
If NO, move on to step 4.
Stage 4:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change)
and remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Disconnect the connector from component 754, measure the resistance of brake 2 solenoid valve
(on the connector of the internal wiring harness of the transmission) between the following connections:
●Connection code 5R.
●Connection code 5LW.
The resistance must be 5.3 ΩΩ Ω Ω
± 0.5 ΩΩ Ω Ω
at 20 ˚C.
Is the resistance correct?
If YES, move on to step 5.
If NO, move on to step 6.
Stage 5:
Measure the continuity and insulation of the following connections:
●Connection code 5R,
●Connection code 5LW.
Between components R22 and the internal connector in the transmission.
Are the continuity and insulation correct?
If YES, contact the Techline.
If NO, replace the intermediate wiring harness between connector R22 and the internal connector in the
transmission.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 93V3 MR-372-J84-23A000$495.mif
AJ0 BVA
Vdiag No.: 04, 05
DF301
CONTINUED
Step 1:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change) and
remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Check the continuity and insulation of the following connections on the internal wiring harness:
●Connection code 5CZ, between components 119 and the pressure switch on clutch 1.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, replace the pressure switch on clutch 1.
If NO, replace the internal wiring harness.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 95V3 MR-372-J84-23A000$495.mif
AJ0 BVA
Vdiag No.: 04, 05
DF302
CONTINUED
Step 1:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change) and
remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Check the continuity and insulation of the following connections on the internal wiring harness:
●Connection code 5LM, between components 119 and the pressure switch on clutch 2.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, replace the pressure switch on clutch 2.
If NO, replace the internal wiring harness.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A - 97V3 MR-372-J84-23A000$495.mif
AJ0 BVA
Vdiag No.: 04, 05
DF303
CONTINUED
Step 1:
Drain the automatic transmission (see, MR 370, Mechanical, 23A Automatic transmission, Oil change) and
remove the transmission housing (see, MR 370, Mechanical, 23A Automatic transmission, Hydraulic
distributor).
Check the continuity and insulation of the following connections on the internal wiring harness:
●Connection code 5LH, between components 119 and the pressure switch on clutch 3.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Are the continuity and insulation correct?
If YES, replace the pressure switch on clutch 3.
If NO, replace the internal wiring harness.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition, wait 1 minute and carry out a road test followed by another
check with the diagnostic tool.