2009 CHERY TIGGO engine

[x] Cancel search: engine

Page 393 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Diagnostic Procedure
1.CHECK GROUND CONNECTIONS
• Turn ignition switch off.
• Loosen and retighten ground screws on the body (See Ground In

Page 394 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 3.CHECK THE THROTTLE POSITION SENSOR (TPS) POWER SUPPLY CIRCUIT
• Turn ignition switch on.
• Check supply voltage between TPS terminal 3 an

Page 395 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 6.CHECK TPS
• Check resistance between TPS terminal 2 and 3.
• 2k ± 20 % (20°C) should exist.
• Turn ignition switch off.
• Connect

Page 396 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine P0132 - O2Sensor 1 Circuit High Voltage
DIAGNOSIS & TESTING
LTSMW030054T
03–11 2Chery Automobile Co., Ltd.

Page 397 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine DIAGNOSIS & TESTING
LTSMW030055T
03
03–11 3Chery Automobile Co., Ltd.

Page 398 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINAL NO.ITEMCONDITIONDATA (DC VOLTAGE)
18 Upstr

Page 399 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Diagnostic Procedure
1.CHECK GROUND CONNECTIONS
• Turn ignition switch off.
• Loosen and retighten ground screws on the body (See Ground In

Page 400 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine •Continuity should exist.
• Check harness short to power supply circuit.
Is the check result normal?
Ye s>>Go to the next step.
No
>>Repair