2009 CHERY TIGGO ABS

[x] Cancel search: ABS

Page 305 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine PINCIRCUIT IDENTIFICATION PINCIRCUIT IDENTIFICATION
35 Sensor (GND) 76Power Steering Switch
36 Sensor (GND) 77Headlamp Switch
37 Manifold Absol

Page 308 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine DTCDTC DEFINITION
P0032 O
2Sensor Heater Control Circuit (Bank 1 Sensor 1) High
P0036 O
2Sensor Heater Control Circuit (Bank 1 Sensor 2)
P0037

Page 311 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine DTCDTC DEFINITION
P2196 O
2Sensor Signal Stuck Rich; Bank 1 Sensor 1
P2270 O
2Sensor Signal Stuck Lean; Bank 1 Sensor 2
P2271 O
2Sensor Signal

Page 352 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine P0105 - Manifold Absolute Pressure/Barometric Pressure Circuit
P0106 - Manifold Absolute Pressure Or Barometric Pressure Range/Performance
DIAG

Page 353 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINALNO. ITEM
CONDITION DATA (DC
VOLTAGE)
17 Sen

Page 354 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine 2.CHECK MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR ELECTRICAL CONNECTOR
• Disconnect the MAP sensor (1) electrical connector.
• Inspect the el

Page 357 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine P0107 - Manifold Absolute Pressure Or Barometric Pressure Low Input
P0108 - Manifold Absolute Pressure Or Barometric Pressure High Input
DIAGNO

Page 358 of 1903

CHERY TIGGO 2009  Service Repair Manual Downloaded from www.Manualslib.com manuals search engine Check reference values between ECM terminals and ground under the following conditions:
ECM TERMINALNO. ITEM
CONDITION DATA (DC
VOLTAGE)
17 Sen
Page:   < prev 1-8 9-16 17-24 25-32 33-40 41-48 ... 80 next >