Page 3624 of 5121
![NISSAN TEANA 2008 Service Manual PG-106
< ON-VEHICLE MAINTENANCE >[POWER SUPPLY&GROUND CIRCUIT]
BATTERY CHARGING CHART
Set charging current to value specified in “Initial Charging Current Setting (Slow Charge)”. If charger
is n NISSAN TEANA 2008 Service Manual PG-106
< ON-VEHICLE MAINTENANCE >[POWER SUPPLY&GROUND CIRCUIT]
BATTERY CHARGING CHART
Set charging current to value specified in “Initial Charging Current Setting (Slow Charge)”. If charger
is n](/manual-img/5/57391/w960_57391-3623.png)
PG-106
< ON-VEHICLE MAINTENANCE >[POWER SUPPLY&GROUND CIRCUIT]
BATTERY CHARGING CHART
Set charging current to value specified in “Initial Charging Current Setting (Slow Charge)”. If charger
is not capable of producing specified current value, set its charging current as close to that value as
possible.
Keep battery away from open flame while it is being charged.
When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
If battery temperature rises above 55°C (131°F), stop charging. Always charge battery when its tem-
perature is below 55°C (131°F).
Standard ChargeINFOID:0000000003809463
1.DETERMINE INITIAL CHARGING CURRENT
1. Determine initial charging current from specific gravity.
2. Check battery type and determine the specified current using the table.
NOTE:
After starting charging, adjustment of charging current is not necessary.
Initial Charging Current Setting (Standard Charge)
>> GO TO 2.
2.CHARGE BATTERY
Charge battery for 8 hours.
>> GO TO 3.
3.CHECKING SPECIFIC GRAVITY
Check specific gravity. Refer to PG-3, "
How to Handle Battery".
Is the specific gravity 1.240 or more?
YES >> Complete standard charge. Perform “CAPACITY TEST”. Refer to PG-5, "Work Flow".
NO >> GO TO 4.
4.CONDUCT ADDITIONAL CHARGE
Add charging time depending on specific gravity.
Additional Charge (Standard Charge)
CONVERTED SPECIFIC
GRAVITYBATTERY TYPE
28B19R(L)
34B19R(L)
46B24R(L)
55B24R(L)
50D23R(L)
55D23R(L)
025 [YUASA type code]
027 [YUASA type code]
80D23R(L)
65D26R(L)
80D26R(L)
067 [YUASA type code]
096 [YUASA type code]
75D31R(L)
95D31R(L)
115D31R(L)
110D26R(L)
95E41R(L)
130E41R(L)
1.100 - 1.130 4.0 (A) 5.0 (A) 6.0 (A) 7.0 (A)8.0
(A)9.0 (A)13.0
(A)
1.130 - 1.160 3.0 (A) 4.0 (A) 5.0 (A) 6.0 (A)7.0
(A)8.0 (A)11 . 0
(A)
1.160 - 1.190 2.0 (A) 3.0 (A) 4.0 (A) 5.0 (A)6.0
(A)7.0 (A)9.0
(A)
1.190 - 1.220 2.0 (A) 2.0 (A) 3.0 (A) 4.0 (A)5.0
(A)5.0 (A)7.0
(A)
SPECIFIC GRAVITY CHARGING TIME (h)
Below 1.150 3.5
1.150 - 1.200 2.5
1.200 - 1.240 1.5
Page 3625 of 5121
![NISSAN TEANA 2008 Service Manual PG
BATTERY CHARGING CHART
PG-107
< ON-VEHICLE MAINTENANCE >[POWER SUPPLY&GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L B A
O
P N
>> Complete standard charge. Perform “CAPACITY TEST”. Refer to PG-5, "Work NISSAN TEANA 2008 Service Manual PG
BATTERY CHARGING CHART
PG-107
< ON-VEHICLE MAINTENANCE >[POWER SUPPLY&GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L B A
O
P N
>> Complete standard charge. Perform “CAPACITY TEST”. Refer to PG-5, "Work](/manual-img/5/57391/w960_57391-3624.png)
PG
BATTERY CHARGING CHART
PG-107
< ON-VEHICLE MAINTENANCE >[POWER SUPPLY&GROUND CIRCUIT]
C
D
E
F
G
H
I
J
K
L B A
O
P N
>> Complete standard charge. Perform “CAPACITY TEST”. Refer to PG-5, "Work Flow".
CAUTION:
Never use standard charge method on a battery whose specific gravity is less than 1.100.
Set charging current to value specified in “Initial Charging Current Setting (Standard Charge)”. If
charger is not capable of producing specified current value, set its charging current as close to that
value as possible.
Keep battery away from open flame while it is being charged.
When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
If battery temperature rises above 55°C (131°F), stop charging. Always charge battery when its tem-
perature is below 55°C (131°F).
Quick ChargeINFOID:0000000003809464
1.DETERMINE INITIAL CHARGING CURRENT
1. Determine initial charging current setting and charging time from specific gravity.
2. Check battery type and determine the specified current using the table.
NOTE:
After starting charging, adjustment of charging current is not necessary.
Initial Charging Current Setting and Charging Time (Quick Charge)
CAUTION:
Never use quick charge method on a battery whose specific gravity is less than 1.100.
Set initial charging current to value specified in “Initial Charging Current Setting and Charging Time
(Quick Charge)”. If charger is not capable of producing specified current value, set its charging cur-
rent as close to that value as possible.
Keep battery away from open flame while it is being charged.
When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
Be careful of a rise in battery temperature because a large current flow is required during quick-
charge operation.
If battery temperature rises above 55°C (131°F), stop charging. Always charge battery when its tem-
perature is below 55°C (131°F).
Never exceed the charging time specified in “Initial Charging Current Setting and Charging Time
(Quick Charge)”, because charging battery over the charging time can cause deterioration of the
battery.
BATTERY TYPE
28B19R(L)
34B19R(L)
46B24R(L)
55B24R(L)
50D23R(L)
55D23R(L)
80D23R(L)
65D26R(L)
80D26R(L)
025 [YUASA type code]
027 [YUASA type code]
067 [YUASA type code]
096 [YUASA type code]
75D31R(L)
95D31R(L)
115D31R(L)
110D26R(L)
95E41R(L)
130E41R(L)
CURRENT [A] 10 15 20 25 30 40
CONVERTED SPECIFIC GRAVITY
1.100 -
1.1302.5 hours
1.130 -
1.1602.0 hours
1.160 -
1.1901.5 hours
1.190 -
1.2201.0 hour
Above
1.2200.75 hour (45 min.)
Page 3626 of 5121
PG-108
< ON-VEHICLE MAINTENANCE >[POWER SUPPLY&GROUND CIRCUIT]
BATTERY CHARGING CHART
>> GO TO 2.
2.CHARGE BATTERY
Charge battery.
>> Complete quick charge. Perform “CAPACITY TEST”. Refer to PG-5, "
Work Flow".
Page 3630 of 5121
PG-112
< SERVICE DATA AND SPECIFICATIONS (SDS) [POWER SUPPLY&GROUND CIRCUIT]
SERVICE DATA AND SPECIFICATIONS (SDS)
SERVICE DATA AND SPECIFICATIONS (SDS)
SERVICE DATA AND SPECIFICATIONS (SDS)
BatteryINFOID:0000000003792694
Ty p e110D26L
20 hour rate capacity [V - Ah] 12 - 75
Cold cranking current (For reference value) [A] 720