Page 2076 of 3924

INFINITI FX35 2008  Service Manual 
EC-836
< SERVICE INFORMATION >[VK45DE]
DTC P0137, P0157 HO2S2
Diagnosis Procedure
INFOID:0000000001326677
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground

Page 2084 of 3924

INFINITI FX35 2008  Service Manual 
EC-844
< SERVICE INFORMATION >[VK45DE]
DTC P0138, P0158 HO2S2
TER-
MI-
NAL 
NO. WIRE 
COLOR ITEM CONDITION DATA (DC Voltage)
6R Heated oxygen sensor 2 
heater (Bank 1) [Engine is running]
 Engine sp

Page 2086 of 3924

INFINITI FX35 2008  Service Manual 
EC-846
< SERVICE INFORMATION >[VK45DE]
DTC P0138, P0158 HO2S2
Diagnosis Procedure
INFOID:0000000001326686
PROCEDURE FOR MALFUNCTION A
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen

Page 2095 of 3924

INFINITI FX35 2008  Service Manual 
DTC P0139, P0159 HO2S2EC-855
< SERVICE INFORMATION > [VK45DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
TER-
MI-
NAL 
NO. WIRE 
COLOR ITEM CONDITION DATA (DC Voltage)
6R Heated oxygen sensor 2 
heater (Bank 1)

Page 2097 of 3924

INFINITI FX35 2008  Service Manual 
DTC P0139, P0159 HO2S2EC-857
< SERVICE INFORMATION > [VK45DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Diagnosis ProcedureINFOID:0000000001326695
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loo

Page 2104 of 3924

INFINITI FX35 2008  Service Manual 
EC-864
< SERVICE INFORMATION >[VK45DE]
DTC P0171, P0174 FUEL IN
JECTION SYSTEM FUNCTION
Do not use ECM ground terminals when measuring in put/output voltage. Doing so may result in dam-
age to the EC

Page 2106 of 3924

INFINITI FX35 2008  Service Manual 
EC-866
< SERVICE INFORMATION >[VK45DE]
DTC P0171, P0174 FUEL IN
JECTION SYSTEM FUNCTION
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnosis ProcedureI

Page 2114 of 3924

INFINITI FX35 2008  Service Manual 
EC-874
< SERVICE INFORMATION >[VK45DE]
DTC P0172, P0175 FUEL IN
JECTION SYSTEM FUNCTION
Do not use ECM ground terminals when measuring in put/output voltage. Doing so may result in dam-
age to the EC