315II. A/C System Diagnosis and TroubleshootingTable 1 Abnormal high pressure of the high pressure pipelineAbnormal low pressure of the high pressure pipeline Abnormal high pressure of the low pressure pipelineAbnormal low pressure of the low pressure pipelineHigh and low pressure can not be establishedSight glass has air bubble Compressor inlet side is frosted Compressor noise Abnormal heating on the compressorEvaporator is frostedDrier filter ices up A/C does not refrigerate or the cold air is insufficient× × × × Excessive refill of refrigerantDrain p rop er amount of
refrigerant
× × × × T oo lit t le refill of refrigerantRep air t he gas leak area, refill
p rop er amount of refrigerant
× × × × Refrigerant is leaked allRep air t he gas leak area, refill
p rop er amount of refrigerant
×× ××× ×T here is non-clot t ed gas in
the sy stemLoos en receiver and
condenser inlet connect or,
discharge t he non-clot t ed gas
××Excessive freez ing oil in t he
sy stemCheck comp ressor freez ing
oil level, adjus t it
× Excessive high t emp erat ure
of condenser inletPerform t he check at t he
p lace w it h good vent ilat ion
T here is dus t in t he
condens er core, air channel
w it hin t he condens er is
blocked or suffocat edU s e comp res s ed air or w at er
t o flush and remove t he dirt
on t he condenser
Condenser fan faulty or
brokenCheck the wiring status and
t he fan mot or, correct or
rep lace it
×× Exces s ively low t emp erat ure
of condenser inletStop the op eration of the
refrigerat ion sy st em
× × × Drier blocked Clean
A ir channel in t he evap orat or
blocked or suffocat edRemove t he dirt on t he
evap orat or
Evap orat or fan fault , p oor
blower mot or w ire connect ionCheck the wiring status and
t he fan mot or, correct or
rep lace it
×× ×T here is dirt in evap orat or
coreU s e t he comp res s ed air t o
clean t he evap orat or core × ×
××××
× P roblem Sy mp t om
Possible Cause T roubleshoot ing
×