POWER-ASSISTED STEERING
Fault finding – Interpretation of faults
36B
36B-16V5 MR-372-J84-36B000$462_fra.mif
EPAS
Vdiag no.: 05, 09,
0D
DF020
PRESENT
OR
STOREDCOMPUTER SUPPLY VOLTAGE
1.DEF: Voltage too low
2.DEF: Voltage too high
CO: Open circuit
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is considered present when the engine is running.
Notes:
This fault causes a degraded assistance (no warning light or message) until assistance
is lost (below 9 V or above 17 V) with STOP warning light + Message.
–The computer records an occurrence context (computer operating values frozen
when fault occurs). To view this information, click on the fault description (camera
symbol). Within these values, parameter PR143 Internal fault code gives the fault
finding procedure to apply.
Procedure to apply for internal fault code 135 of the PR143
Check the conditioning and positioning of the EPAS supply fuses:
–Power fuse (80A BP81) in the engine fuse box.
–AP44 after ignition fuse (5A) in the Protection and Switching Unit.
Check the condition and tightness of the battery and alternator terminals, as well as the Protection and Switching
Unit bolt.
Carry out fault finding on the charge circuit.
Repair if necessary.
Disconnect the two black connectors from the EPAS computer.
Check the condition and conformity of the connectors and their clips.
Check the conformity of the electrical supplies (they must be equal to the battery voltage).
In the event of a fault, check the insulation, continuity and the absence of interference resistance on the
following connections:
8-track connector track 8 + 12 V after ignition
2-track connector track 1 + 12 V before ignition feed
2-track connector track 2 Earth
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRClear the stored faults.
Check that the EPAS is working.
Deal with any other faults.
DAE_V05_DF020/DAE_V09_DF020/DAE_V0D_DF020