Page 90 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-90V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET003
BRAKE LIGHT SWITCH (OPENING)
NOTESThere must be no present or stored faults.
The status displays "OPEN" with the pedal released and changes to "CLOSED" with the brake pedal depressed.
Check the cleanliness and the condition of the brake light switch connections.
Check the position, setting and correct operation of the brake light switch. (Watch out for the floor carpet which can
jam the switch.)
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference resistance
on the following connection:
●connection code 5A, between components 119 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the correct status is not displayed, replace the switch.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET003/DP0TA2005_V18_ET003
Page 91 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-91V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET004
STOP LIGHT SWITCH (CLOSURE)
NOTESThere must be no present or stored faults.
The status displays "CLOSED" with the pedal released and changes to "OPEN" with the brake pedal depressed.
Check the cleanliness and the condition of the brake light switch connections.
Check the position, setting and correct operation of the brake light switch. (Watch out for the floor carpet which
can jam the switch.)
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference
resistance on the following connection:
●connection code 5A, between components 119 and 160.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the correct status is not displayed, replace the switch.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_ET004/DP0TA2005_V18_ET004
Page 94 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of statuses
23A
23A-94V5 MR-372-J84-23A100$580.mif
SIEMENS TA2005
Vdiag No.: 14-18
ET012
CONTINUED
LEVER POSITION
"P"-"R"-"N"-"D"
(CONTINUED)
Disconnect the multifunction switch.
Use the universal bornier Elé. 1681 to check the insulation, continuity and
the absence of interference resistance on the following connections:
●connection code 5DG, between components 119 and 485,
●connection code 5DH, between components 119 and 485,
●connection code 5DJ, between components 119 and 485,
●connection code 5DK, between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical
Note 6015A, Electrical wiring repair, Wiring: Precautions for repair), repair the wiring,
otherwise replace it.
Check the cleanliness and the condition of the sequential lever module connections.
Disconnect the battery. Disconnect the computer.
Check the cleanliness and condition of the connections.
Use the Universal bornier Elé. 1681.
Check the insulation, continuity and absence of interference resistance on
the following connections:
●connection code 5FM, between components 119 and 129.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A,
Electrical wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise
replace it.
●connection code 5H, between components 119 and 129.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A,
Electrical wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise
replace it.
●connection code N between components 129 and 107.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A,
Electrical wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise
replace it.
LEVER POSITION
"M
dblquote
Incrementation
"M+" AND
"M-
dblquote
AFTER REPAIRRepeat the conformity check from the start.
Page 109 of 139
Fault finding - Interpretation of parameters23A
23A - 109V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters
PR001
COOLANT TEMPERATURE
NOTESSpecial notes:
Only apply the checks if the parameter is inconsistent.
Run a multiplex network test (see 88B, Multiplex).
If parameter PR001 Coolant temperature is absent, refer to the interpretation of the parameter (see MR 366
Megane, 17B, Petrol injection or 13B, Diesel injection).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR001/DP0TA2005_V18_PR001
MR-372-J84-23A100$696.mif
Page 112 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 112V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR006
ENGINE SPEED
NOTESThere must be no present or stored faults.
Run a multiplex network test (see 88B, Multiplex).
After these checks, if parameter PR006 Engine speed is absent, refer to the interpretation of the parameter
(see 17B, Petrol injection or 13B, Diesel injection).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR006/DP0TA2005_V18_PR006
Page 115 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 115V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR105
VEHICLE SPEED
NOTESThere must be no present or stored faults.
Run a multiplex network test (88B, Multiplex).
If parameter PR105 Vehicle speed is absent, carry out fault finding on the system (see 38C, ABS).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR105/DP0TA2005_V18_PR105
Page 116 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 116V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR118
GEARBOX OIL PRESSURE SENSOR VOLTAGE
NOTESNo faults should be present or stored.
ELECTRICAL CONFORMITY OF THE SENSOR:
Check for continuity and absence of interference resistance on the following connections:
●connection code 5U, between components 119 and 781,
●connection code 5W, between components 119 and 781,
●connection code 5V, between components 119 and 781.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If all the connections are correct, check for + 5 V on connection 5U of component 781.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If all the connections are correct, check for earth on connection 5V of component 781.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR118/DP0TA2005_V18_PR118
Page 117 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 117V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR123
CALCULATED ENGINE TORQUE
NOTESThere must be no present or stored faults.
Run a multiplex network test (see 88B, Multiplex).
If parameter PR123 Calculated engine torque is absent, refer to the interpretation of the parameter (see 17B,
Petrol injection or 13B, Diesel injection).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR123/DP0TA2005_V18_PR123