Page 36 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-36V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF089
PRESENT
OR
STOREDEVS4 SEQUENCE SOLENOID VALVE CIRCUIT
CC.0: Short circuit to earth
CO: Open circuit
CC.1: Short circuit to + 12 V
NOTESDeal with fault DF012 Solenoid valves supply first if it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Repair if necessary.
Check the insulation, continuity and absence of interference resistance on the following connections:
●connection code 5AU, between components 119 and 754,
●connection code 5AY, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●connection code 5AY,
●connection code 5AU.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Replace the solenoid valve or the electric/hydraulic interface wiring harness if the resistance is not 40 Ω ± 2
at 23˚C.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF089/DP0TA2005_V18_DF089
Page 37 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-37V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF093
PRESENT
OR
STOREDMANUAL SEQUENTIAL CONTROLS CIRCUIT
1.DEF: Inconsistency of the signal
CC.0: Short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears during a road test when selecting position M with the lever
(one- touch control).
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance of the following connections:
●connection code 5FM, between components 119 and 129,
●connection code 5H, between components 119 and 129,
●connection code 5DU, between components 119 and 129,
●connection code N, between components 107 and 129.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF093/DP0TA2005_V18_DF093
Page 41 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-41V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF109
PRESENT
OR
STOREDENGINE TORQUE MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF109/DP0TA2005_V18_DF109
Page 42 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-42V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF112
PRESENT
OR
STOREDEVS6 SEQUENCE SOLENOID VALVE CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
NOTESDeal with fault DF012 Solenoid valves supply first if it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connectors.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●connection code 5AU, between components 119 and 754,
●connection code 5DM, between components 119 and 754.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●connection code 5DM,
●connection code 5AU.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring. Otherwise replace the wiring.
Replace the solenoid valve or the electric/hydraulic interface wiring harness if the resistance is not 40 Ω ± 2
at 23˚C.
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF112/DP0TA2005_V18_DF112
Page 46 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-46V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF145
PRESENT
OR
STOREDINVALID PEDAL POSITION MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESConditions for applying the fault finding procedure to stored faults:
If the fault appears following a road test during which the quality of the gear changes
deteriorates.
Disconnect the battery.
Disconnect the gearbox computer. Check the cleanliness and condition of the connectors.
Disconnect the engine management computer. Check the cleanliness and condition of the connectors.
If the fault is still present, run fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
Repair if necessary.
Run a multiplex network test (see 88B, Multiplex).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF145/DP0TA2005_V18_DF145
Page 47 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-47V5 MR-372-J84-23A100$348.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF147
PRESENT
OR
STOREDINVALID ANTICIPATED TORQUE MULTIPLEX SIGNAL
1.DEF: Multiplex frames absent or values invalid (fault with the computer generating
the signal or multiplex line connection fault)
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF147/DP0TA2005_V18_DF147
Page 50 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-50V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF185
PRESENT
OR
STOREDNO ABS/ESP MULTIPLEX SIGNAL
1.DEF: Carry out the multiplex network fault finding procedure
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the system (see 38C, ABS).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF185/DP0TA2005_V18_DF185
Page 51 of 139
AUTOMATIC TRANSMISSION
Fault finding - Interpretation of faults
23A
23A-51V5 MR-372-J84-23A100$406.mif
SIEMENS TA2005
Vdiag No.: 14-18
DF186
PRESENT
OR
STOREDINJECTION MULTIPLEX SIGNAL ABSENT
1.DEF: Carry out the multiplex network fault finding procedure
NOTESNone.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the injection system (see 17B, Petrol injection or 13B, Diesel
injection).
If the problem is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2005_V14_DF186/DP0TA2005_V18_DF186