EC-222
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
P1121 ELECTRIC THROTTLE CONTROL ACTUATOR
P1121 ELECTRIC THROTTLE CONTROL ACTUATOR
DescriptionINFOID:0000000001670987
Electric throttle control actuator consists of throttle control motor, throttle position sensor, etc.
The throttle control motor is operated by the ECM and it opens and closes the throttle valve.
The throttle position sensor detects the throttle valve position, and the opening and closing speed of the throt-
tle valve and feeds the voltage signals to the ECM. The ECM judges the current opening angle of the throttle
valve from these signals and the ECM controls the throttle control motor to make the throttle valve opening
angle properly in response to driving condition.
DTC LogicINFOID:0000000001670988
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
>> GO TO 2.
2.PERFORM DTC CONFIRMATION PROCEDURE FOR MALFUNCTION A AND B
1. Turn ignition switch ON and wait at least 1 second.
2. Set shift lever to D (A/T), 1st (M/T) position and wait at least 3 seconds.
3. Set shift lever to P or N (A/T), Neutral (M/T) position.
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Turn ignition switch ON and wait at least 1 second.
6. Set shift lever to D (A/T), 1st (M/T) position and wait at least 3 seconds.
7. Set shift lever to P or N (A/T), Neutral (M/T) position.
8. Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
9. Check DTC.
Is DTC detected?
YES >> Go to EC-222, "Diagnosis Procedure".
NO >> GO TO 3.
3.PERFORM DTC CONFIRMATION PROCEDURE FOR MALFUNCTION C
1. Turn ignition switch ON and wait at least 1 second.
2. Set shift lever to D (A/T), 1st (M/T) position and wait at least 3 seconds.
3. Set shift lever to P or N (A/T), Neutral (M/T) position.
4. Start engine and let it idle for 3 seconds.
5. Check DTC.
Is DTC detected?
YES >> Go to EC-222, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis ProcedureINFOID:0000000001670989
1.CHECK ELECTRIC THROTTLE CONTROL ACTUATOR VISUALLY
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1121Electric throttle control
actuatorA)Electric throttle control actuator does not func-
tion properly due to the return spring malfunc-
tion.
Electric throttle control actuator
B)Throttle valve opening angle in fail-safe mode is
not in specified range.
C) ECM detect the throttle valve is stuck open.
EC-234
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
P1143 HO2S1
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
Do you have CONSULT-III?
YES >> GO TO 2.
NO >> GO TO 3.
2.PERFORM DTC CONFIRMATION PROCEDURE
1. Start engine and warm it up to normal operating temperature.
2. Stop engine and wait at least 10 seconds.
3. Turn ignition switch ON and select “HO2S1 (B1) P1143” of “HO2S1” in “DTC WORK SUPPORT” mode
with CONSULT-III.
4. Touch “START”.
5. Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If the engine speed limit is exceeded,
return to step 5.
6. When the following conditions are met, “TESTING” will be displayed on the CONSULT-III screen. Maintain
the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take approximately 50
seconds or more.)
CAUTION:
Always drive vehicle at a safe speed.
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Touch “SELF-DIAG RESULT”
Which is displayed on CONSULT-III screen?
OK >> INSPECTION END
NG >> Go to EC-234, "
Diagnosis Procedure".
3.PERFORM COMPONENT FUNCTION CHECK
With GST
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM harness connector terminals as follows under the following condition.
NOTE:
Use component function check to check the overall function of the heated oxygen sensor 1 circuit. During this
check, a 1st trip DTC might not be confirmed.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC-234, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001671006
1.CHECK GROUND CONNECTION
1. Turn ignition switch OFF.
2. Check ground connection E15. Refer to Ground Inspection in GI-58, "
Circuit Inspection".
Is the inspection result normal?
ENG SPEED 1,375 - 2,600 rpm
VHCL SPEED SE Less than 100 km/h (62 MPH)
B/FUEL SCHDL 3.7 - 10.0 msec
Shift lever Suitable position
ECM Ground
Condition Voltage
Connector Terminal Connector Terminal
F1149
(HO2S1 signal)F11 56Engine speed held at
2,000 rpm constant under
no load The maximum voltage is over 0.6 at least 1
time.
The minimum voltage is over 0.1 at least 1
time.
P1143 HO2S1
EC-235
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
N
P O
YES >> GO TO 2.
NO >> Repair or replace ground connection.
2.RETIGHTEN HEATED OXYGEN SENSOR 1
Loosen and retighten heated oxygen sensor 1. Refer to EM-159, "
Removal and Installation".
>> GO TO 3.
3.CLEAR THE SELF-LEARNING DATA
1. Clear mixture ratio self-learning value, refer to EC-29, "
MIXTURE RATIO SELF-LEARNING VALUE
CLEAR : Special Repair Requirement".
2. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171 detected or difficult to start engine?
Yes >> Perform trouble diagnosis for DTC P0171. Refer to EC-179, "DTC Logic".
No >> GO TO 4.
4.CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to EC-164, "
Component Inspection".
Is inspection result normal?
YES >> GO TO 5.
NO >> Replace heated oxygen sensor 1.
5.CHECK INTERMITTENT INCIDENT
Perform GI-55, "
Intermittent Incident".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair or replace.
6.REPLACE HEATED OXYGEN SENSOR 1
Replace heated oxygen sensor 1.
>> INSPECTION END
Component InspectionINFOID:0000000001671007
1.INSPECTION START
Do you have CONSULT-III?
Do you have CONSULT-III?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK HEATED OXYGEN SENSOR 1
With CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Set “POST TRIGGER” to 100% in “DATA MONITOR” mode with CONSULT-III.
3. Select “HO2S1 (B1)” and “HO2S1 MNTR (B1)”.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch “RECORD” on CONSULT-III screen.
EC-236
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
P1143 HO2S1
6. Check the following.
- “HO2S1 MNTR (B1)” in “DATA MONITOR” mode changes from
“RICH” to “LEAN” to “RICH” more than 5 times in 10 seconds.
5 times (cycles) are counted as shown in the figure.
- “HO2S1 (B1)” voltage goes above 0.6V at least once.
- “HO2S1 (B1)” voltage goes below 0.3V at least once.
- “HO2S1 (B1)” voltage never exceeds 1.0V.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool and approved anti-seize lubricant.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 3.
3.CHECK HEATED OXYGEN SENSOR 1
Without CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Check the voltage between ECM harness connector terminals as follows under the following condition.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool and approved anti-seize lubricant.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 4
4.REPLACE HEATED OXYGEN SENSOR 1
Replace heated oxygen sensor 1.
SEF217YA
JMBIA0352ZZ
(+) (–)
Condition Voltage
Connector Terminal Connector Terminal
F1149
(HO2S1 signal)F11 56Engine speed held at
2,000 rpm constant
under no load. The voltage fluctuates between 0 to 0.3V and 0.6
to 1.0V more than 5 times within 10 seconds.
The maximum voltage is over 0.6V at least 1
time.
The minimum voltage is below 0.3V at least 1
time.
The voltage never exceeds 1.0V.
1 time: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V
2 times: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 -
1.0V → 0 - 0.3V
P1144 HO2S1
EC-239
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
N
P O
Do you have CONSULT-III?
YES >> GO TO 2.
NO >> GO TO 3.
2.PERFORM DTC CONFIRMATION PROCEDURE
1. Start engine and warm it up to normal operating temperature.
2. Stop engine and wait at least 10 seconds.
3. Turn ignition switch ON and select “HO2S1 (B1) P1144” of “HO2S1” in “DTC WORK SUPPORT” mode
with CONSULT-III.
4. Touch “START”.
5. Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm after this step. If the engine speed limit is exceeded,
return to step 5.
6. When the following conditions are met, “TESTING” will be displayed on the CONSULT-III screen. Maintain
the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take approximately 50
seconds or more.)
CAUTION:
Always drive vehicle at a safe speed.
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Touch “SELF-DIAG RESULT”
Which is displayed on CONSULT-III screen?
OK >> INSPECTION END
NG >> Go to EC-239, "
Diagnosis Procedure".
3.PERFORM COMPONENT FUNCTION CHECK
With GST
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM harness connector terminals as follows under the following condition.
NOTE:
Use component function check to check the overall function of the heated oxygen sensor 1 circuit. During this
check, a 1st trip DTC might not be confirmed.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Go to EC-239, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001671010
1.CHECK GROUND CONNECTION
1. Turn ignition switch OFF.
2. Check ground connection E15. Refer to Ground Inspection in GI-58, "
Circuit Inspection".
Is the inspection result normal?
YES >> GO TO 2.
NO >> Repair or replace ground connection.
ENG SPEED 1,375 - 2,600 rpm
VHCL SPEED SE Less than 100 km/h (62 MPH)
B/FUEL SCHDL 3.7 - 10.0 msec
Shift lever Suitable position
(+) (–)
Condition Voltage
Connector Terminal Connector Terminal
F1149
(HO2S1 signal)F11 56Engine speed held at 2,000 rpm
constant under no load The maximum voltage is over 0.8 at
least 1 time.
The minimum voltage is over 0.35 at
least 1 time.
EC-240
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
P1144 HO2S1
2.RETIGHTEN HEATED OXYGEN SENSOR 1
Loosen and retighten heated oxygen sensor 1. Refer to EM-159, "
Removal and Installation".
>> GO TO 3.
3.CLEAR THE SELF-LEARNING DATA
1. Clear the mixture ratio self-learning value, refer to EC-29, "
MIXTURE RATIO SELF-LEARNING VALUE
CLEAR : Special Repair Requirement".
2. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected or difficult to start engine?
Yes >> Perform trouble diagnosis for DTC P0172. Refer to EC-179, "DTC Logic".
No >> GO TO 4
4.CHECK HO2S1 CONNECTOR FOR WATER
1. Turn ignition switch OFF.
2. Disconnect heated oxygen sensor 1 harness connector.
3. Check connectors for water.
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace harness or connectors.
5.CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to EC-164, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 6.
NO >> Replace heated oxygen sensor 1.
6.CHECK HEATED OXYGEN SENSOR 1
Refer to EC-150, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 7.
NO >> Replace heated oxygen sensor 1.
7.CHECK INTERMITTENT INCIDENT
Refer to GI-55, "
Intermittent Incident".
>>INSPECTION END
Component InspectionINFOID:0000000001671011
1.INSPECTION START
Do you have CONSULT-III?
Do you have CONSULT-III?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK HEATED OXYGEN SENSOR 1
With CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Set “POST TRIGGER” to 100% in “DATA MONITOR” mode with CONSULT-III.
3. Select “HO2S1 (B1)” and “HO2S1 MNTR (B1)”.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch “RECORD” on CONSULT-III screen.Water should not exist.
P1144 HO2S1
EC-241
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
N
P O
6. Check the following.
- “HO2S1 MNTR (B1)” in “DATA MONITOR” mode changes from
“RICH” to “LEAN” to “RICH” more than 5 times in 10 seconds.
5 times (cycles) are counted as shown in the figure.
- “HO2S1 (B1)” voltage goes above 0.6V at least once.
- “HO2S1 (B1)” voltage goes below 0.3V at least once.
- “HO2S1 (B1)” voltage never exceeds 1.0V.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m
(19.7 in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor
Thread Cleaner tool and approved anti-seize lubricant.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 4.
3.CHECK HEATED OXYGEN SENSOR 1
Without CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Check the voltage between ECM harness connector terminals as follows under the following condition.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool and approved anti-seize lubricant.
Is the inspection result normal?
YES >> INSPECTION END
NO >> GO TO 4.
4.REPLACE HEATED OXYGEN SENSOR 1
Replace heated oxygen sensor 1.
CAUTION:
SEF217YA
JMBIA0352ZZ
(+) (–)
Condition Voltage
Connector Terminal Connector Terminal
F1149
(HO2S1 signal)F11 56Engine speed
held at 2,000 rpm
constant under no
load The voltage fluctuates between 0 to 0.3V and 0.6
to 1.0V more than 5 times within 10 seconds.
The maximum voltage is over 0.6V at least 1 time.
The minimum voltage is below 0.3V at least 1 time.
The voltage never exceeds 1.0V.
1 time: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V
2 times: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 -
1.0V → 0 - 0.3V
EC-244
< COMPONENT DIAGNOSIS >[HR16DE (WITH EURO-OBD)]
P1146 HO2S2
>> GO TO 3.
3.PERFORM PROCEDURE FOR COND1-I
Start engine and warm it up to normal operating temperature.
>> GO TO 4.
4.PERFORM PROCEDURE FOR COND1-II
Turn ignition switch OFF and wait at least 10 seconds.
>> GO TO 5.
5.PERFORM PROCEDURE FOR COND1-IV
1. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
2. Let engine idle 1 minute.
3. Select “HO2S2 (B1) P1146” of “HO2S2” in “DTC WORK SUPPORT” mode with CONSULT-III.
4. Touch “START”.
5. Start engine and let it idle for at least 30 seconds.
6. Rev engine up to 2,000 rpm two or three times quickly under no load.
Is
“CONPLETED” appears on CONSULT-III screen?
YES >> GO TO 9.
NO >> GO TO 6.
6.PERFORM PROCEDURE FOR COND1-I
When the following conditions are met, “TESTING” will be displayed at “COND1” on the CONSULT-III screen.
Maintain the condition continuously until “TESTING” changes to “COMPLETED” (It will take approximately 60
seconds.)
Which displayed on CONSULT-III screen?
COND1: OUT OF CONDITION>>GO TO 4.
COND1: COMPLETED COND2: INCOMPLETED>>GO TO 7.
COND1: COMPLETED COND2: COMPLETED>>GO TO 8.
7.PERFORM PROCEDURE FOR COND2
While driving, release accelerator pedal completely from the above condition until “INCOMPLETED” at
“COND2” on CONSULT-III screen has turned to “COMPLETED”. (It will take approximately 4 seconds.)
Which displayed on CONSULT-III screen?
COND2: COMPLETED COND3: INCOMPLETED>>GO TO 8.
COND2: COMPLETED COND3: COMPLETED>>GO TO 9.
8.PERFORM PROCEDURE FOR COND3
Stop vehicle and let it idle until “INCOMPLETED” of “COND3” on CONSULT-III screen has turned to “COM-
PLETED”. (It will take a maximum of approximately 6 minutes.)
>> GO TO 9.
9.PERFORM PROCEDURE FOR COND3-I
Touch “SELF DIAGRESULTS”.
Which displayed on CONSULT-III screen?
OK >> INSPECTION END
NG >> Go to EC-246, "
Diagnosis Procedure".
ENG SPEED More than 1,000 rpm
B/FUEL SCHDL More than 1.0 msec
COOLAN TEMP/S More than 70°C (158°F)
Shift level Suitable position