2007 ISUZU KB P190 service

[x] Cancel search: service

Page 3323 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–45 
 
 
Clean around the area where the fuel  
injectors enter the lower intake manifold. 
3  Remove the bolt (1), three places, attaching the fue

Page 3327 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–49 
 
6 1  Connect the test lamp between the battery 
voltage circuit of the ignition coil and to each  
ground circuit of the ignition coil. 
Doe

Page 3343 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–65 
 
Step Action  Yes No 
6 Test the HO2S heater control circuit for a high resistance, open  
circuit, short to ground or short to voltage fault

Page 3346 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–68 
 
Additional Information 
• Refer to 6C1-1 Engine Management – V6 – General Information for details of the HO2S system operation. 
•

Page 3350 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–72 
 
Step Action  Yes No 
8 Test the MAF sensor 5 V reference circuit for a high resistance, open  
circuit or short to voltage fault condition.

Page 3351 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–73 
 
• Increased temperature in the intake air decreases the resistance value of the IAT sensor. This increases the IAT  
sensor pull-down rate

Page 3352 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–74 
 
Step Action  Yes No 
2 1  Switch off the ignition for 30 seconds.  
2  Start the engine. 
3  Allow the engine to reach the normal operating

Page 3354 of 6020

ISUZU KB P190 2007  Workshop Repair Manual Engine Management – V6 – Diagnostics Page 6C1-2–76 
 
Conditions for Setting the DTC 
DTC P0116 
The ECM detects the engine coolant temperature sensor value is 10°C less than the minimum calcul