2007 ISUZU KB P190 engine oil

[x] Cancel search: engine oil

Page 4401 of 6020

ISUZU KB P190 2007  Workshop Repair Manual TRANSMISSION CONTROL SYSTEM (JR405E)   7A2-117
H1: Judder Occurs at Lock Up  
H2: Large Shock at Lock Up  
H3: Lock Up Point is High or Low  
I1: No Lock Up 
Diagnosis Hints • Causes such as the sol

Page 4402 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-118   TRANSMISSION CONTROL SYSTEM (JR405E)
J1: Transmission Fluid Leaks from Breather  
J2: Transmission Fluid Leaks Between Engine and Converter Housing 
J3: Transmission Fluid Leaks Between Conv

Page 4403 of 6020

ISUZU KB P190 2007  Workshop Repair Manual TRANSMISSION CONTROL SYSTEM (JR405E)   7A2-119
Z2: Mode Lamp (Power Drive or 3rd Start) Does Not Turn On  
Z3: Mode Lamp (Power Drive or 3rd Start) Does Not Turn Off  
Z4: A/T Oil Temperature Lamp Tur

Page 4405 of 6020

ISUZU KB P190 2007  Workshop Repair Manual TRANSMISSION CONTROL SYSTEM (JR405E)   7A2-121
Test Instructions
Line Pressure Test
Legend1. Oil cooler (outlet)  
2. Low & reverse brake pressure detection port (R range line pressure detection port)

Page 4406 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-122   TRANSMISSION CONTROL SYSTEM (JR405E)
Standard Value 
Diagnosis  1. If the line pressure is lower than the standard value at idle in all ranges. 
• Abraded oil pump. 
• Faulty operation o

Page 4407 of 6020

ISUZU KB P190 2007  Workshop Repair Manual TRANSMISSION CONTROL SYSTEM (JR405E)   7A2-123
Stall Test
Stall Test Procedure1. Fully apply the parking brake and chock all wheels. 
2. Check the level of the engine oil, coolant and transmission flu

Page 4408 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-124   TRANSMISSION CONTROL SYSTEM (JR405E)
Time Lag Test
Time Lag Test Procedure1. Fully apply the parking brake and chock all wheels. 
2. Check the level of the engine oil, coolant and transmissi

Page 4418 of 6020

ISUZU KB P190 2007  Workshop Repair Manual 7A2-134   TRANSMISSION CONTROL SYSTEM (JR405E)
TCM Signal Test 
Inspection Tool 
Use a DMM to measure voltage and circuit continuity. 
Also use an oscilloscope to measure waveform. Refer 
to the follo