Page 885 of 4366

REMOTE KEYLESS ENTRY SYSTEM BL-73
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
CHECK BACK DOOR SWITCH
1. CHECK BACK DOOR SWITCH INPUT SIGNAL
With CONSULT-II
Check (“BACK DOOR SW”) in “DATA MONITOR” mode with CONSULT-II.
Without CONSULT-II
Check voltage between BCM connector and ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> GO TO 2.
2. CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect BCM and back door closure motor connector.
3. Check continuity between BCM connector B14 terminal 58 and back door closure motor connector D109 terminal 7.
4. Check continuity between BCM connector B14 terminal 58 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Monitor item Condition DATA MONITOR
BACK DOOR SW OPEN
↓
CLOSE ON
↓
OFF
PIIA2488E
Connector Terminals (Wire color)
Condition Voltage (V)
(Approx.)
(+) (–)
B14 58 (L) Ground OPEN 0
CLOSE 9
PIIA6229E
58 (L) – 7 (L) : Continuity should exist.
58 (L) – Ground : Continuity should not exist.
PIIA6226E
Page 886 of 4366
BL-74
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
3. CHECK GROUND CIRCUIT
Check continuity between back door closure motor connector D109
terminal 8 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK BACK DOOR SWITCH
Check continuity between back door closure motor D109 terminals 7
and 8.
OK or NG
OK >> GO TO 5.
NG >> Replace back door closure motor.
5. CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM connector and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Replace BCM. 8 (B) – Ground : Continuity should exist.
PIIA6170E
Terminals Back door condition Continuity
78 Open Yes
Close No
PIIA9934E
58 (L) – Ground : Approx. 9V
PIIA6229E
Page 887 of 4366

REMOTE KEYLESS ENTRY SYSTEM BL-75
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
Check Key SwitchNIS001MV
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check ignition key switch “KEY ON SW” in “DATA MONITOR” mode
with CONSULT-II.
When key is inserted in ignition key cylinder
When key is removed from ignition key cylinder
Without CONSULT-II
Check voltage between BCM connector M3 terminal 37 (B/W) and
ground.
OK or NG
OK >> Key switch circuit is OK.
NG >> GO TO 2.
2. CHECK KEY SWITCH
1. Disconnect key switch connector.
2. Check continuity between key switch terminals 1 and 2.
OK or NG
OK >> Check the following.
15A fuse [No. 22, located in fuse block (J/B)]
Harness for open or short between key switch and fuse
Harness for open or short between BCM and key switch
NG >> Replace key switch. KEY ON SW : ON
KEY ON SW : OFF
PIIA6470E
Condition of ignition key cylinder Voltage (V)
Approx.
Key is inserted Battery voltage
Key is removed 0
PIIA6471E
Terminal Key switch condition Continuity
12 Key is inserted in IGN key cylinder. Yes
Key is removed from IGN key cylinder No
PIIA2627E
Page 888 of 4366
BL-76
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
Check Remote Keyless Entry ReceiverNIS001MW
1. CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Check remote keyless entry receiver connector M98 terminal 2 (L) and ground signal with oscilloscope.
OK or NG
OK >> Remote keyless entry receiver circuit is OK.
NG >> GO TO 2.
2. CHECK REMOTE KEYLESS ENTRY RECEIVER INPUT VOLTAGE
1. Disconnect remote keyless entry receiver connector.
2. Check voltage between remote keyless entry receiver connector M98 terminal 4 (R) and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
Connector Terminal
(Wire color) Condition
of keyfob Vo l ta g e
(Reference value)
(+) (–)
M98 2 Ground No function
Any button is pressed
PIIB1375E
OCC3879D
OCC3880D
4 (Y) – Ground : Approx. 4.5V
PIIB3953E
Page 889 of 4366

REMOTE KEYLESS ENTRY SYSTEM BL-77
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
3. CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between remote keyless entry receiver connector M78 terminal 4 (R) and BCM connec- tor M1 terminal 19 (R).
3. Check continuity between remote keyless entry receiver connector M78 terminal 4 (R) and ground.
OK or NG
OK >> Check harness connection.
If it is OK, replace BCM.
If it is NG, repair or replace malfunction part.
NG >> Repair or replace the harness.
4. CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
1. Check continuity between remote keyless entry receiver con- nector M78 terminal 1 (B) and ground.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT
1. Check continuity between remote keyless entry receiver con- nector M78 terminal 1 (B) and BCM connector M1 terminal 18
(B)
OK or NG
OK >> Check harness connection.
If it is OK, replace BCM.
If it is NG, repair or replace malfunction part.
NG >> Repair or replace the harness. 4 (R) – 19 (R) : Continuity should exist.
4 (R) – Ground : Continuity should not exist.
PIIA9630E
1 (B) – Ground : Continuity should exist.
PIIB1376E
1 (B) – 18 (B) : Continuity should exist.
PIIB3952E
Page 890 of 4366
BL-78
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
6. CHECK REMOTE KEYLESS ENTRY RECEIVER SIGNAL CIRCUIT
1. Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and BCM connec- tor M1 terminal 20 (Y).
2. Check continuity between remote keyless entry receiver connector M78 terminal 2 (Y) and ground.
OK or NG
OK >> Check harness connection.
If it is OK, replace remote keyless entry receiver.
If it is NG, repair or replace malfunction part.
NG >> Repair or replace harness. 2 (Y) – 20 (Y) : Continuity should exist.
2 (Y) – Ground : Continuity should not exist.
PIIA9633E
Page 891 of 4366
REMOTE KEYLESS ENTRY SYSTEM BL-79
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2006 July 2007 FX35/FX45
Check IPDM E/R OperationNIS001MX
1. CHECK IPDM E/R INPUT VOLTAGE
Check voltage between IPDM E/R connector E9 terminal 51 and
ground.
OK or NG
OK >> Replace IPDM E/R.
NG >> GO TO 2.
2. CHECK IPDM E/R HARNESS
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R and horn relay connector.
3. Check continuity between IPDM E/R connector E9 terminal 51 and horn relay connector E10 terminal 1.
OK or NG
OK >> Check harness connection.
NG >> Repair or replace harness. 51 (SB) – Ground : Battery voltage
PIIA6403E
51 (SB) – 1 (SB) : Continuity should exist.
PIIA6404E
Page 892 of 4366

BL-80
REMOTE KEYLESS ENTRY SYSTEM
Revision: 2006 July 2007 FX35/FX45
Check Hazard Warning Lamp FunctionNIS001MY
1. CHECK HAZARD WARNING LAMP
Do hazard warning lamp flash with hazard switch?
YES or NO
YES >> Hazard warning lamp circuit is OK.
NO >> Check hazard circuit. Refer to LT- 9 0 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Check Horn FunctionNIS001MZ
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-13, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
YES or NO
YES >> Horn circuit is OK.
NO >> Check horn circuit. Refer to WW-58, "
HORN" .
Check Headlamp FunctionNIS001N0
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-13, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HEADLAMP FUNCTION
Does headlamp come on when turning lighting switch “ON”?
YES or NO
YES >> Headlamp operation circuit is OK.
NO >> Check headlamp system. Refer to LT- 6 , "
HEADLAMP - XENON TYPE -" .
Check Map Lamp and Ignition Keyhole Illumination FunctionNIS001N1
1. CHECK MAP LAMP AND IGNITION KEYHOLE ILLUMINATION FUNCTION
When map lamp switch is in “DOOR” position, open the front door (LH or RH).
OK or NG
OK >> Replace BCM.
NG >> Check ignition illumination circuit. Refer to LT- 1 5 2 , "
INTERIOR ROOM LAMP" .