Page 2687 of 4366
![INFINITI FX35 2007 Service Manual FUEL INJECTOR EC-1311
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
FUEL INJECTORPFP:16600
Component DescriptionNBS004GY
The fuel injector is a small, precise sol INFINITI FX35 2007 Service Manual FUEL INJECTOR EC-1311
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
FUEL INJECTORPFP:16600
Component DescriptionNBS004GY
The fuel injector is a small, precise sol](/manual-img/42/57018/w960_57018-2686.png)
FUEL INJECTOR EC-1311
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
FUEL INJECTORPFP:16600
Component DescriptionNBS004GY
The fuel injector is a small, precise solenoid valve. When the ECM
supplies a ground to the fuel injector circuit, the coil in the fuel injec-
tor is energized. The energized coil pulls the ball valve back and
allows fuel to flow through the fuel injector into the intake manifold.
The amount of fuel injected depends upon the injection pulse dura-
tion. Pulse duration is the length of time the fuel injector remains
open. The ECM controls the injection pulse duration based on
engine fuel needs.
CONSULT-II Reference Value in Data Monitor ModeNBS004GZ
Specification data are reference values.
SEF375Z
MONITOR ITEM CONDITION SPECIFICATION
B/FUEL SCHDL See EC-802, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
INJ PULSE-B1
INJ PULSE-B2
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No load Idle 2.0 - 3.0 msec
2,000 rpm 1.9 - 2.9 msec
Page 2703 of 4366
ICC BRAKE SWITCH EC-1327
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
2. CHECK OVERALL FUNCTION-II
With CONSULT-II
Check “BRAKE SW2” indication in “DATA MONITOR” mode.
Without CONSULT-II
Check voltage between ECM terminal 101 and ground under the fol-
lowing conditions.
OK or NG
OK >> INSPECTION END
NG >> GO TO 12.
3. CHECK DTC WITH ICC UNIT
Refer to ACS-42, "
TROUBLE DIAGNOSIS FOR SELF-DIAGNOSTIC ITEMS" .
OK or NG
OK >> GO TO 4.
NG >> Repair or replace.
CONDITION INDICATION
Brake pedal: Fully released OFF
Brake pedal: Slightly depressed ON
SEC013D
CONDITION VOLTAGE
Brake pedal: Fully released Approximately 0V
Brake pedal: Slightly depressed Battery voltage
PBIB1537E
Page 2721 of 4366
REFRIGERANT PRESSURE SENSOR EC-1345
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
REFRIGERANT PRESSURE SENSORPFP:92136
Component DescriptionNBS004HA
The refrigerant pressure sensor is installed at the condenser of the
air conditioner system. The sensor uses an electrostatic volume
pressure transducer to convert refrigerant pressure to voltage. The
voltage signal is sent to ECM, and ECM controls cooling fan system.
PBIB1492E
PBIB2657E
Page 2723 of 4366
![INFINITI FX35 2007 Service Manual REFRIGERANT PRESSURE SENSOR EC-1347
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal a INFINITI FX35 2007 Service Manual REFRIGERANT PRESSURE SENSOR EC-1347
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal a](/manual-img/42/57018/w960_57018-2722.png)
REFRIGERANT PRESSURE SENSOR EC-1347
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS004HC
1. CHECK REFRIGERANT PRESSURE SENSOR OVERALL FUNCTION
1. Start engine and warm it up to normal operating temperature.
2. Turn A/C switch and blower fan switch ON.
3. Check voltage between ECM terminal 70 and ground with CON- SULT-II or tester.
OK or NG
OK >> INSPECTION END
NG >> GO TO 2.
2. CHECK GROUND CONNECTIONS
1. Turn A/C switch and blower fan switch OFF.
2. Turn ignition switch OFF.
3. Loosen and retighten three ground screws on the body. Refer to EC-819, "
Ground Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Repair or replace ground connections.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
49 PU Sensor power supply
(Refrigerant pressure sen-
sor) [Ignition switch: ON]
Approximately 5V
67 B/W Sensor ground [Engine is running]
Warm-up condition
Idle speed Approximately 0V
70 L/R Refrigerant pressure sensor [Engine is running]
Warm-up condition
Both A/C switch and blower fan motor
switch: ON (Compressor operates) 1.0 - 4.0V
Voltage: 1.0 - 4.0V
PBIB1188E
PBIB2195E
Page 2731 of 4366
![INFINITI FX35 2007 Service Manual VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1355
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)PFP:14956
Descripti INFINITI FX35 2007 Service Manual VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1355
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)PFP:14956
Descripti](/manual-img/42/57018/w960_57018-2730.png)
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS) EC-1355
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)PFP:14956
DescriptionNBS004GN
SYSTEM DESCRIPTION
*: The ECM determines the start signal status by the signals of engine speed and battery voltage.
When the engine is running at low or medium speed, the power valve is fully closed. Under this condition, the
effective suction port length is equivalent to the total length of the intake manifold collector's suction port
including the intake valve. This long suction port provides increased air intake which results in improved suc-
tion efficiency and higher torque generation.
The surge tank and one-way valve are provided. When engine is running at high speed, the ECM sends the
signal to the VIAS control solenoid valve. This signal introduces the intake manifold vacuum into the power
valve actuator and therefore opens the power valve to two suction passages together in the collector.
Under this condition, the effective port length is equivalent to the length of the suction port provided indepen-
dently for each cylinder. This shortened port length results in enhanced engine output with reduced suction
resistance under high speeds.
The power valve is always open regardless of the engine speed when gear position is in N or P.
Sensor Input signal to ECM ECM function Actuator
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE) Engine speed*
VIAS control VIAS control solenoid valve
Mass air flow sensor Amount of intake air
Throttle position sensor Throttle position
Accelerator pedal position sensor Accelerator pedal position
Battery Battery voltage*
Engine coolant temperature sensor Engine coolant temperature
PBIB1876E
Page 2732 of 4366
![INFINITI FX35 2007 Service Manual EC-1356
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
COMPONENT DESCRIPTION
Power Valve
The power valve is installed in intake manifold collector and used t INFINITI FX35 2007 Service Manual EC-1356
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
COMPONENT DESCRIPTION
Power Valve
The power valve is installed in intake manifold collector and used t](/manual-img/42/57018/w960_57018-2731.png)
EC-1356
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
COMPONENT DESCRIPTION
Power Valve
The power valve is installed in intake manifold collector and used to
control the suction passage of the variable induction air control sys-
tem. It is set in the fully closed or fully opened position by the power
valve actuator (1) operated by the vacuum stored in the surge tank.
The vacuum in the surge tank is controlled by the VIAS control sole-
noid valve.
: Vehicle front
VIAS Control Solenoid Valve
The VIAS control solenoid valve (1) cuts the intake manifold vacuum
signal for power valve control. It responds to ON/OFF signals from
the ECM. When the solenoid is off, the vacuum signal from the
intake manifold is cut. When the ECM sends an ON signal the coil
pulls the plunger downward and feeds the vacuum signal to the
power valve actuator.
Vacuum tank (2)
CONSULT-II Reference Value in Data Monitor ModeNBS004GO
PBIB3237E
PBIB3236E
MONITOR ITEM CONDITION SPECIFICATION
VIAS S/V
Selector lever: P or N ON
Engine speed: More than 5,000 rpm
Selector lever: Except P or N
Engine speed: Less than 5,000 rpm OFF
Page 2734 of 4366
EC-1358
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
29 GY VIAS control solenoid valve [Engine is running]
Selector lever: P or N
0 - 1.0V
[Engine is running]
Selector lever: D
Engine speed: Below 5,000 rpm BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Engine speed: Above 5,000 rpm 0 - 1.0V
Page 2736 of 4366
![INFINITI FX35 2007 Service Manual EC-1360
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to p INFINITI FX35 2007 Service Manual EC-1360
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to p](/manual-img/42/57018/w960_57018-2735.png)
EC-1360
[VK45DE]
VARIABLE INDUCTION AIR CONTROL SYSTEM (VIAS)
Revision: 2006 July 2007 FX35/FX45
2. CHECK VACUUM EXISTENCE
With CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Start engine and let it idle.
3. Perform “VIAS SOL VALVE” in “ACTIVE TEST” mode with CON- SULT-II.
4. Turn VIAS control solenoid valve “ON” and “OFF”, and check vacuum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
3. CHECK VACUUM EXISTENCE
Without CONSULT-II
1. Stop engine and disconnect vacuum hose connected to power valve actuator.
2. Disconnect VIAS control solenoid valve (1) harness connector.
–Vacuum tank (2)
3. Start engine and let it idle.
4. Apply 12V of direct current between VIAS control solenoid valve terminals 1 and 2.
5. Check vacuum existence under the following conditions.
OK or NG
OK >> Repair or replace power valve actuator.
NG >> GO TO 4.
VIAS SOL VALVE Vacuum
ON Should exist.
OFF Should not exist.
PBIB0844E
PBIB3236E
Condition Vacuum
12V direct current supply Should exist
No supply Should not exist
PBIB0845E