Page 2473 of 4366
![INFINITI FX35 2007 Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1097
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS0048M
NOTE:
If DTC Confirmation INFINITI FX35 2007 Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1097
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS0048M
NOTE:
If DTC Confirmation](/manual-img/42/57018/w960_57018-2472.png)
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1097
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS0048M
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode with CONSULT-II.
5. Make sure that “FUEL T/TMP SE” is more than 0 °C (32 °F).
6. Start engine and wait at least 20 seconds. If 1st trip DTC is detected, go to EC-1099, "
Diagnostic Proce-
dure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Check that voltage between ECM terminal 107 (Fuel tank tem- perature sensor signal) and ground is less than 4.2V.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and wait at least 20 seconds.
5. Select “Service $07” with GST. If 1st trip DTC is detected, go to EC-1099, "
Diagnostic Proce-
dure" .
SEF194Y
PBIB1110E
Page 2475 of 4366
![INFINITI FX35 2007 Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1099
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured betwe INFINITI FX35 2007 Service Manual DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1099
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured betwe](/manual-img/42/57018/w960_57018-2474.png)
DTC P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1099
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS0048O
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body. Refer to EC-819, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. CHECK CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check sensor harness connector for water.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness connector.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
32 OR EVAP control system pres-
sure sensor [Ignition switch: ON]
Approximately 1.8 - 4.8V
48 L Sensor power supply
(EVAP control system pres-
sure sensor) [Ignition switch: ON]
Approximately 5V
67 B/W Sensor ground [Engine is running]
Warm-up condition
Idle speed Approximately 0V
PBIB2195E
Water should not exist.
PBIB1522E
Page 2479 of 4366
![INFINITI FX35 2007 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1103
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS0048T
NOTE:
If DTC Confirmation INFINITI FX35 2007 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1103
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS0048T
NOTE:
If DTC Confirmation](/manual-img/42/57018/w960_57018-2478.png)
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1103
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
DTC Confirmation ProcedureNBS0048T
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “DATA MONITOR” mode with CONSULT-II.
5. Make sure that “FUEL T/TMP SE” is more than 0 °C (32 °F).
6. Start engine and wait at least 20 seconds.
7. If 1st trip DTC is detected, go to EC-1105, "
Diagnostic Proce-
dure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Check that voltage between ECM terminal 107 (Fuel tank tem- perature sensor signal) and ground is less than 4.2V.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and wait at least 20 seconds.
5. Select “Service $07” with GST. If 1st trip DTC is detected, go to EC-1105, "
Diagnostic Proce-
dure" .
SEF194Y
PBIB1110E
Page 2481 of 4366
![INFINITI FX35 2007 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1105
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured betwe INFINITI FX35 2007 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1105
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured betwe](/manual-img/42/57018/w960_57018-2480.png)
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1105
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureNBS0048V
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body. Refer to EC-819, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. CHECK CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check sensor harness connector for water.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness connector.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
32 OR EVAP control system pres-
sure sensor [Ignition switch: ON]
Approximately 1.8 - 4.8V
48 L Sensor power supply
(EVAP control system pres-
sure sensor) [Ignition switch: ON]
Approximately 5V
67 B/W Sensor ground [Engine is running]
Warm-up condition
Idle speed Approximately 0V
PBIB2195E
Water should not exist.
PBIB1522E
Page 2487 of 4366
![INFINITI FX35 2007 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1111
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation Proc INFINITI FX35 2007 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1111
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation Proc](/manual-img/42/57018/w960_57018-2486.png)
DTC P0455 EVAP CONTROL SYSTEM EC-1111
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation ProcedureNBS0048Y
CAUTION:
Never remove fuel filler cap during the DTC Confirmation Procedure.
NOTE:
Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve
properly.
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait
at least 10 seconds before conducting the next test.
TESTING CONDITION:
Perform “DTC WORK SUPPORT” when the fuel level is between 1/4 and 3/4 full, and vehicle is
placed on flat level surface.
Open engine hood before conducting the following procedures.
WITH CONSULT-II
1. Tighten fuel filler cap securely until ratcheting sound is heard.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
5. Make sure that the following conditions are met. COOLAN TEMP/S: 0 - 70 °C (32 - 158 °F)
INT/A TEMP SE: 0 - 60 °C (32 - 140 °F)
6. Select “EVAP SML LEAK P0442/P1442” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CONSULT-II.
Follow the instruction displayed.
NOTE:
If the engine speed cannot be maintained within the range displayed on the CONSULT-II screen, go to
EC-738, "
Basic Inspection" .
PBIB2869E
PBIB0829E
Page 2488 of 4366
![INFINITI FX35 2007 Service Manual EC-1112
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 July 2007 FX35/FX45
7. Make sure that “OK” is displayed.
If “NG” is displayed, select “SELF-DIAG RESULTS” mode and
make sure INFINITI FX35 2007 Service Manual EC-1112
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 July 2007 FX35/FX45
7. Make sure that “OK” is displayed.
If “NG” is displayed, select “SELF-DIAG RESULTS” mode and
make sure](/manual-img/42/57018/w960_57018-2487.png)
EC-1112
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 July 2007 FX35/FX45
7. Make sure that “OK” is displayed.
If “NG” is displayed, select “SELF-DIAG RESULTS” mode and
make sure that “EVAP GROSS LEAK [P0455]” is displayed. If it
is displayed, refer to E C - 111 2 , "
Diagnostic Procedure" .
If P0442 is displayed, perform Diagnostic Procedure for DTC
P0442 EC-1059, "
Diagnostic Procedure" .
WITH GST
NOTE:
Be sure to read the explanation of EC-725, "
Driving Pattern" before driving vehicle.
1. Start engine.
2. Drive vehicle according to EC-725, "
Driving Pattern" .
3. Stop vehicle.
4. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
5. Select “Service $07” with GST.
If P0455 is displayed on the screen, go to E C - 111 2 , "Diagnostic Procedure" .
If P0442 is displayed on the screen, go to EC-1059, "Diagnostic Procedure" .
If P0441 is displayed on the screen, go to EC-1053, "Diagnostic Procedure" .
Diagnostic ProcedureNBS0048Z
1. CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch OFF.
2. Check for genuine NISSAN fuel filler cap design.
OK or NG
OK >> GO TO 2.
NG >> Replace with genuine NISSAN fuel filler cap.
2. CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened properly by rotating the cap clockwise.
OK or NG
OK >> GO TO 3.
NG >> 1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
2. Retighten until ratcheting sound is heard.
3. CHECK FUEL FILLER CAP FUNCTION
Check for air releasing sound while opening the fuel filler cap.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
SEC763C
SEF915U
Page 2491 of 4366
![INFINITI FX35 2007 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1115
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF.
2 INFINITI FX35 2007 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1115
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF.
2](/manual-img/42/57018/w960_57018-2490.png)
DTC P0455 EVAP CONTROL SYSTEM EC-1115
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 July 2007 FX35/FX45
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF.
2. Apply 12 volts DC to EVAP canister vent control valve. The valve will close. (Continue to apply 12 volts until the end of test.)
3. Pressurize the EVAP line using pressure pump with 1.3 to 2.7 kPa (10 to 20 mmHg, 0.39 to 0.79 inHg), then remove pump and EVAP service port adapter.
CAUTION:
Do not use compressed air or a high pressure pump.
Do not exceed 4.12 kPa (0.042 kg/cm2 , 0.6 psi) of pressure in the system.
4. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details. Refer
to EC-701, "
EVAPORATIVE EMISSION LINE DRAWING" .
OK or NG
OK >> GO TO 12.
NG >> Repair or replace.
11 . CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-II screen to increase “PURG VOL CONT/V” opening to 100%.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 14.
NG >> GO TO 13.
PBIB1522E
SEF200U
Vacuum should exist.
PBIB1678E
Page 2492 of 4366
![INFINITI FX35 2007 Service Manual EC-1116
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 July 2007 FX35/FX45
12. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and warm INFINITI FX35 2007 Service Manual EC-1116
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 July 2007 FX35/FX45
12. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and warm](/manual-img/42/57018/w960_57018-2491.png)
EC-1116
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2006 July 2007 FX35/FX45
12. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine.
3. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
4. Start engine and let it idle for at least 80 seconds.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 15.
NG >> GO TO 13.
13. CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to EC-769, "
Vacuum Hose Drawing" .
OK or NG
OK (With CONSULT-II)>>GO TO 14.
OK (Without CONSULT-II)>>GO TO 15.
NG >> Repair or reconnect the hose.
14. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1. Start engine.
2. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK >> GO TO 16.
NG >> GO TO 15.
15. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-1078, "
Component Inspection" .
OK or NG
OK >> GO TO 16.
NG >> Replace EVAP canister purge volume control solenoid valve.
16. CHECK FUEL TANK TEMPERATURE SENSOR
Refer to EC-1003, "
Component Inspection" .
OK or NG
OK >> GO TO 17.
NG >> Replace fuel level sensor unit. Vacuum should exist.
PBIB1678E