Page 574 of 4366
ATC-128
HEATER & COOLING UNIT ASSEMBLY
Revision: 2006 July 2007 FX35/FX45
Disassembly and AssemblyNJS000EV
1. Heater pipe grommet 2. Heater core 3. Heater pipe cover
4. Aspirator 5. Aspirator hose 6. Air mix door motor (driver side)
7. Air mix door (slide door) 8. Max. cool door link 9. Max. cool door lever
10. Ventilator door lever 11. Ventilator door link 12. Air mix door motor (passenger side)
13. Intake sensor bracket 14. Intake sensor 15. Foot duct (right)
16. Evaporator cover 17. Evaporator cover adaptor 18. Heater pipe bracket
PJIA0157E
Page 575 of 4366
HEATER & COOLING UNIT ASSEMBLY ATC-129
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
19. Insulator 20. Heater case (right) 21. Low-pressure pipe 2
22. O-ring 23. High-pressure pipe 3 24. Expansion valve
25. Evaporator 26. Heater case (left) 27. Foot duct (left)
28. Center case 29. Max. cool door (left) 30. Ventilator door
31. Side link 32. Mode door motor 33. Defroster door
34. Max. cool door (right) 35. Defroster door lever 36. Defroster door link
: N·m (kg-m, in-lb)
: Always replace after every disassembly.
Page 578 of 4366
ATC-132
HEATER CORE
Revision: 2006 July 2007 FX35/FX45
HEATER COREPFP:27140
Removal and InstallationNJS000EY
REMOVAL
1. Remove heater & cooling unit assembly. Refer to ATC-125, "HEATER & COOLING UNIT ASSEMBLY" .
2. Remove foot duct (left). Refer to ATC-136, "
Removal of Foot Ducts" .
3. Remove mounting screws, and then remove heater pipe cover.
4. Remove heater pipe bracket.
5. Slide heater core (shown in the figure) to driver side.
INSTALLATION
Installation is basically the reverse order of removal.
RJIA2046E
Page 582 of 4366
ATC-136
DUCTS AND GRILLES
Revision: 2006 July 2007 FX35/FX45
Removal of Foot Ducts
1. Remove heater & cooling unit assembly. Refer to ATC-125, "HEATER & COOLING UNIT ASSEMBLY" .
2. Remove mounting screws, and then remove air mix door motor (right), mode door motor, evaporator cover and foot duct (right).
3. Remove foot duct (left).
Removal of Floor Ducts
1. Remove floor carpet. Refer to EI-41, "FLOOR TRIM" .
2. Remove mounting clips, and then remove side floor ducts.
3. Remove instrument panel and pad. Refer to IP-10, "
INSTRU-
MENT PANEL ASSEMBLY" .
4. Remove mounting clip, and then remove center floor duct with rear ventilator duct 1 attached.
5. Remove center floor duct from rear ventilator duct 1.
INSTALLATION
Installation is basically the reverse order of removal.
RJIA0962E
RJIA2055E
RJIA2054E
Page 587 of 4366

REFRIGERANT LINES ATC-141
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
VK45DE
1. Use a refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant.
2. Remove air cleaner case and air duct. Refer to EM-17, "
AIR CLEANER AND AIR DUCT" (VQ35DE) or
EM-177, "
AIR CLEANER AND AIR DUCT" (VK45DE).
3. Remove front engine undercover, using power tools.
4. Remove cooling fan shroud (lower). Refer to CO-41, "
RADIATOR" (VK45DE).
5. Remove mounting nuts from low-pressure flexible hose and high-pressure flexible hose.
CAUTION:
Cap or wrap the joint of compressor, low-pressure flexible
hose and high-pressure flexible hose with suitable material
such as vinyl tape to avoid the entry of air.
6. Remove high-pressure flexible hose. Refer to ATC-147,
"Removal and Installation of High-pressure Flexible Hose"
(VK45DE).
7. Disconnect compressor connector.
8. Remove A/C compressor belt. Refer to EM-15, "
DRIVE BELTS" (VQ35DE) or EM-174, "DRIVE BELTS"
(VK45DE).
RJIA2244E
RJIA2059E
RJIA2058E
Page 599 of 4366

REFRIGERANT LINES ATC-153
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
Removal and Installation of CondenserNJS000FA
REMOVAL
1. Use a refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant.
2. Remove cooling fan. Refer to CO-49, "
COOLING FAN" (VK45DE).
3. Remove radiator cooling fan assembly. Refer to CO-14, "
RADIATOR" (VQ35DE).
4. Remove radiator shroud. Refer to CO-41, "
RADIATOR" (VK45DE).
5. Remove washer tank mounting bolt.
6. Remove high-pressure flexible hose bracket mounting bolt.
7. Disconnect high-pressure flexible hose and high-pressure pipe 1 from condenser.
a. Set a disconnector [condenser outlet (SST: 9253089908), con- denser inlet (SST: 9253089912)] on A/C piping.
b. Slide a disconnector upward until it clicks.
c. Slide A/C piping upward and disconnect it. CAUTION:
Cap or wrap the joint of condenser, high-pressure flexible
hose and high-pressure pipe 1 with suitable material such
as vinyl tape to avoid the entry of air.
8. Remove condenser mounting bolts.
9. Remove radiator upper mount, move radiator and condenser to the engine side.
10. Remove condenser.
PBIC1534E
RJIA2065E
RJIA2066E
SJIA1570E
Page 600 of 4366

ATC-154
REFRIGERANT LINES
Revision: 2006 July 2007 FX35/FX45
CAUTION:
Be careful not to damage the core surface of the condenser and the radiator.
INSTALLATION
Installation is basically the reverse order of removal.
CAUTION:
Replace O-rings of high-pressure flexible hose and high-pressure pipe 1 with new ones, and then
apply compressor oil to it when installing it.
Female-side piping connection is thin and easy to deform. Slowly insert the male-side piping
straight in axial direction.
Insert piping securely until a click is heard.
After piping connection is completed, pull male-side piping by hand to make sure that connection
does not come loose.
When recharging refrigerant, check for leaks.
Removal and Installation of Refrigerant Pressure SensorNJS000FB
REMOVAL
1. Remove condenser. Refer to ATC-153, "Removal and Installation of Condenser" .
2. Remove refrigerant pressure sensor from condenser. CAUTION:
When working, be careful not to damage the condenser.
INSTALLATION
Installation is basically the reverse order of removal.
CAUTION:
Apply compressor oil to O-ring of refrigerant pressure sensor when installing it.
Removal and Installation of EvaporatorNJS000FC
REMOVAL
1. Remove low-pressure pipe 2 and high-pressure pipe 3. Refer to ATC-150, "Removal and Installation of
Low-pressure Pipe 2 and High-pressure Pipe 3" .
CAUTION:
Cap or wrap the joint of evaporator, low-pressure pipe 2 and high-pressure pipe 3 with suitable
material such as vinyl tape to avoid the entry of air.
2. Slide evaporator, and then remove it from heater & cooling unit assembly.
3. Remove intake sensor from evaporator, and then remove evap- orator. High-pressure flexible hose bracket mounting bolt
: 5.5 N·m (0.56 kg-m, 49 in-lb)
RJIA2076E
RJIA0928E
Page 604 of 4366

ATC-158
REFRIGERANT LINES
Revision: 2006 July 2007 FX35/FX45
CHECKING PROCEDURE
To prevent inaccurate or false readings, make sure there is no refrigerant vapor, shop chemicals, or cigarette
smoke in the vicinity of the vehicle. Perform the leak test in calm area (low air/wind movement) so that the
leaking refrigerant is not dispersed.
1. Stop the engine.
2. Connect a suitable A/C manifold gauge set (SST: J-39183) to the A/C service valves.
3. Check if the A/C refrigerant pressure is at least 345 kPa (3.52 kg/cm
2 , 50 psi) above 16 °C (61 °F). If less
than specification, recover/evacuate and recharge the system with the specified amount of refrigerant.
NOTE:
At temperatures below 16 °C (61 °F), leaks may not be detected since the system may not reach 345 kPa
(3.52 kg/cm
2 , 50 psi).
4. Perform the leak test from the high-pressure side (compressor discharge a to evaporator inlet h) to the low-pressure side [evaporator drain hose i to shaft seal o (VK45DE) or n (VQ35DE)]. Refer to ATC-139,
"Components" . Perform a leak check for the following areas carefully. Clean the component to be
checked and move the leak detected probe completely around the connection/component.
Compressor
Check the fitting of high- and low-pressure flexible hoses, relief valve and shaft seal.
Condenser
Check the fitting of high-pressure flexible hose and pipe, refrigerant pressure sensor.
Liquid tank
Check the fitting of refrigerant connection.
Service valves
Check all around the service valves. Ensure service valve caps are secured on the service valves (to pre-
vent leaks).
NOTE:
After removing A/C manifold gauge set from service valves, wipe any residue from valves to prevent any
false readings by leak detector.
Cooling unit (Evaporator)
With engine OFF, turn blower fan on “High” for at least 15 seconds to dissipate any refrigerant trace in the
cooling unit. Wait a minimum of 10 minutes accumulation time (refer to the manufacturer’s recommended
procedure for actual wait time) before inserting the leak detector probe into the drain hose.
Keep the probe inserted for at least 10 seconds. Use caution not to contaminate the probe tip with water
or dirt that may be in the drain hose.
5. If a leak detector detects a leak, verify at least once by blowing compressed air into area of suspected leak, then repeat check as outlined above.
6. Do not stop when one leak is found. Continue to check for additional leaks at all system components. If no leaks are found, perform steps 7 - 10.
7. Start the engine.
8. Set the A/C control as follows;
a. A/C switch: ON
b. Mode door position: VENT (Ventilation)
c. Intake position: Recirculation
d. Temperature setting: Max. cold
e. Fan speed: High
9. Run engine at 1,500 rpm for at least 2 minutes.
10. Stop the engine and perform leak check again following steps 4 through 6 above.
Refrigerant leaks should be checked immediately after stopping
the engine. Begin with the leak detector at the compressor. The
pressure on the high-pressure side will gradually drop after
refrigerant circulation stops and pressure on the low-pressure
side will gradually rise, as shown in the graph. Some leaks are
more easily detected when pressure is high.
SHA839E