LUBRICANT ATC-27
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
LUBRICANTPFP:KLG00
Maintenance of Lubricant Quantity in CompressorNJS000DL
The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compres-
sor when replacing any component or after a large refrigerant leakage occurred. It is important to maintain the
specified amount.
If lubricant quantity is not maintained properly, the following malfunctions may result:
Lack of lubricant: May lead to a seized compressor.
Excessive lubricant: Inadequate cooling (thermal exchange interference)
LUBRICANT
LUBRICANT RETURN OPERATION
Adjust the lubricant quantity according to the test group shown below.
1. CHECK LUBRICANT RETURN OPERATION
Can lubricant return operation be performed?
A/C system works properly.
There is no evidence of a large amount of lubricant leakage.
CAUTION:
If excessive lubricant leakage is noted, never perform the lubricant return operation.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. PERFORM LUBRICANT RETURN OPERATION, PROCEEDING AS FOLLOWS
1. Start the engine, and set to the following conditions:
–Engine speed: Idling to 1,200 rpm
–A/C switch: ON
–Blower speed: Max. position
–Temp. control: Optional [Set so that intake air temperature is 25 to 30 °C (77 to 86 °F).]
–Intake position: Recirculation (REC)
2. Perform lubricant return operation for about 10 minutes.
3. Stop the engine.
>> GO TO 3.
3. CHECK REPLACEMENT PART
Should the compressor be replaced?
YES >> GO TO AT C - 2 9 , "LUBRICANT ADJUSTING PROCEDURE FOR COMPRESSOR REPLACE-
MENT" .
NO >> GO TO AT C - 2 8 , "
LUBRICANT ADJUSTING PROCEDURE FOR COMPONENTS REPLACE-
MENT EXCEPT COMPRESSOR" .
Name : NISSAN A/C System Oil Type S

ATC-30
AIR CONDITIONER CONTROL
Revision: 2006 July 2007 FX35/FX45
AIR CONDITIONER CONTROLPFP:27500
Description of Air Conditioner LAN Control SystemNJS000DM
The LAN (Local Area Network) system consists of unified meter and A/C amp., mode door motor, air mix door
motors and intake door motor.
A configuration of these components is shown in the figure below.
System ConstructionNJS000DN
A small network is constructed between the unified meter and A/C amp., air mix door motors, mode door
motor and intake door motor. The unified meter and A/C amp. and motors are connected by data transmission
lines and motor power supply lines. The LAN network is built through the ground circuits of each door motor.
Addresses, motor opening angle signals, motor stop signals and error checking messages are all transmitted
through the data transmission lines connecting the unified meter and A/C amp. and each door motor.
The following functions are contained in LCUs built into the air mix door motors, the mode door motor and the
intake door motor.
Address
Motor opening angle signals
Data transmission
Motor stop and drive decision
Opening angle sensor (PBR function)
Comparison
Decision (Unified meter and A/C amp. indicated value and motor opening angle comparison)
OPERATION
The unified meter and A/C amp. receives data from each of the sensors. The unified meter and A/C amp.
sends mode door, air mix door and intake door opening angle data to the mode door motor LCU, air mix door
motor LCU and intake door motor LCU.
The mode door motor, air mix door motors and intake door motor read their respective signals according to the
address signal. Opening angle indication signals received from the unified meter and A/C amp. and each of
the motor position sensors is compared by the LCUs in each door motor with the existing decision and open-
ing angles. Subsequently, HOT/COLD, DEF/VENT and FRE/REC operation is selected. The new selection
data is returned to the unified meter and A/C amp.
SJIA1609E
RJIA1747E

AIR CONDITIONER CONTROL ATC-31
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
TRANSMISSION DATA AND TRANSMISSION ORDER
Unified meter and A/C amp. data is transmitted consecutively to each of the door motors following the form
shown in figure below.
Start:
Initial compulsory signal is sent to each of the door motors.
Address:
Data sent from the unified meter and A/C amp. are selected according to data-based decisions made by the
air mix door motor, mode door motor and intake door motor.
If the addresses are identical, the opening angle data and error check signals are received by the door motor
LCUs. The LCUs then make the appropriate error decision. If the opening angle data have no error, door con-
trol begins.
If an error exists, the received data are rejected and corrected data received. Finally, door control is based
upon the corrected opening angle data.
Opening Angle:
Data that shows the indicated door opening angle of each door motor.
Error Check:
In this procedure, transmitted and received data is checked for errors. Error data are then compiled. The error
check prevents corrupted data from being used by the air mix door motor, the mode door motor and the intake
door motor. Error data can be related to the following symptoms.
Malfunction of electrical frequency
Poor electrical connections
Signal leakage from transmission lines
Signal level fluctuation
RJIA1748E

ATC-40
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
TROUBLE DIAGNOSISPFP:00004
CONSULT-II Function (BCM)NJS000DU
CONSULT-II can display each diagnosis item using the diagnosis test modes shown following.
CONSULT-II BASIC OPERATION
Refer to GI-38, "CONSULT-II Start Procedure" .
DATA MONITOR
Operation Procedure
1. Touch “AIR CONDITIONER” on “SELECT TEST ITEM” screen.
2. Touch “DATA MONITOR” on “SELECT DIAG MODE” screen.
3. Touch either “ALL SIGNALS” or “SELECTION FROM MENU” on “DATA MONITOR” screen.
4. When “SELECTION FROM MENU” is selected, touch items to be monitored. When “ALL SIGNALS” is selected, all the items will be monitored.
5. Touch “START”.
6. Touch “RECORD” while monitoring, then the status of the monitored item can be recorded. To stop recording, touch “STOP”.
Display Item List
How to Perform Trouble Diagnosis for Quick and Accurate RepairNJS000DV
WORK FLOW
System part Check item, diagnosis mode Description
BCM Data monitor Displays BCM input data in real time.
All signals Monitors all the items.
Selection from menu Selects and monitors the individual item selected.
Monitor item name “operation or unit” Contents
IGN ON SW “ON/OFF” Displays “IGN position (ON)/OFF, ACC position (OFF)” status as judged from ignition switch signal.
FAN ON SIG “ON/OFF” Displays “FAN (ON)/FAN (OFF)” status as judged from blower fan motor switch signal.
AIR COND SW “ON/OFF” Displays “COMP (ON)/COMP (OFF)” status as judged from air conditioner switch signal.
*1 ATC-60, "Operational Check"
SHA900E

ATC-50
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
Auto Amp. Terminals and Reference ValueNJS000DZ
Measure voltage between each terminal and ground by referring ter-
minals and reference value for unified meter and A/C amp.
PIN CONNECTOR TERMINAL LAYOUT
TERMINALS AND REFERENCE VALUE FOR UNIFIED METER AND A/C AMP.
SJIA1566E
RJIA1966E
Te r m i n a l No. Wire
color Item
Ignition
switch Condition
Voltag e
(V)
1 L CAN-H — — —
11 P C A N - L — — —
21 R/W Power supply from BAT OFF — Battery voltage
22 W Power supply from IGN ON — Battery voltage
29 B Ground (Power) ON — Approx. 0
30 B Ground ON — Approx. 0
35 LG Power supply from ACC ACC — Battery voltage
39 Y Ambient sensor — — —
40 BR/W In-vehicle sensor — — —
41 P Intake sensor — — —
42 R/Y Compressor ON signal ON A/C switch: ON
(Blower motor operates.) Approx. 0
OFF switch: ON
(A/C system: OFF)
43 G/B A/C LAN signal ON —
SJIA1423J
SJIA1453J

ATC-52
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
Self-diagnosis FunctionNJS000E0
DESCRIPTION
The self-diagnosis system diagnoses sensors, door motors, blower motor, etc. by system line. Refer to appli-
cable sections (items) for details. Shifting from normal control to the self-diagnosis system is accomplished by
starting the engine (turning the ignition switch ON) and pressing OFF switch for at least 5 seconds. The OFF
switch must be pressed within 10 seconds after starting the engine (ignition switch is turned ON). This system
will be canceled by either pressing AUTO switch or turning the ignition switch OFF. Shifting from one step is
accomplished by means of pressing temperature control switch (driver side), as required.
Shifting from STEP-5 to AUXILIARY MECHANISM is accomplished by means of pressing (fan) UP switch
(driver side).
SJIA1571E

ATC-60
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
Operational CheckNJS000E1
The purpose of the operational check is to check if the individual system operates properly.
CHECKING MEMORY FUNCTION
1. Press the temperature control (UP) switch (driver side) until 32°C (90 °F) is displayed.
2. Press OFF switch.
3. Turn ignition switch OFF.
4. Turn ignition switch ON.
5. Press the AUTO switch.
6. Confirm that the set temperature remains at previous temperature.
7. Press OFF switch.
If NG, go to trouble diagnosis procedure for ATC-102, "
Memory Function" .
If OK, continue the check.
CHECKING BLOWER
1. Press fan (UP:+) switch. Blower should operate on low speed. The fan symbol should have one blade lit.
2. Press fan (UP:+) switch again, and continue checking blower speed and fan symbol until all speeds are checked.
3. Leave blower on max. speed.
If NG, go to trouble diagnosis procedure for AT C - 7 7 , "
Blower Motor Circuit" .
If OK, continue the check.
CHECKING DISCHARGE AIR
1. Press MODE switch and DEF switch.
2. Each position indicator should change shape.
3. Confirm that discharge air comes out according to the air distri- bution table. Refer to AT C - 3 7 , "
Discharge Air Flow" .
If NG, go to trouble diagnosis procedure for AT C - 6 8 , "
Mode Door
Motor Circuit" .
If OK, continue the check.
NOTE:
Confirm that the compressor clutch is engaged (sound or visual
inspection) and intake door position is at FRE when the D/F or DEF
is selected.
CHECKING INTAKE AIR
1. Press intake switch. Recirculation indicator should illuminate.
2. Press intake switch again. Fresh indicator should illuminate.
3. Listen for intake door position change. (Slight change of blower sound can be heard.)
If NG, go to trouble diagnosis procedure for AT C - 7 4 , "
Intake Door Motor Circuit" .
If OK, continue the check.
NOTE:
Confirm that the compressor clutch is engaged (sound or visual inspection) and intake door position is at FRE
when the D/F or DEF is selected.
CHECKING TEMPERATURE DECREASE
1. Press temperature control (DOWN) switch (driver side) until 18 °C (60 °F) is displayed.
2. Check for cold air at discharge air outlets.
If NG, go to trouble diagnosis procedure for AT C - 9 0 , "
Insufficient Cooling" .
If OK, continue the check.
CHECKING TEMPERATURE INCREASE
1. Press temperature control (UP) switch (driver side) until 32 °C (90 °F) is displayed.
Conditions : Engine running at normal operating temperature
SJIA0302E

TROUBLE DIAGNOSIS ATC-63
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
Potentio Temperature Control (PTC)
The PTC is built into the A/C and AV switch. It can be set at an inter-
val of 0.5 °C (1.0 °F) in the 18 °C (60 °F) to 32 °C (90 °F) temperature
range by pressing temperature control switch. The set temperature
is displayed.
DIAGNOSIS PROCEDURE FOR A/C SYSTEM
SYMPTOM: A/C system does not come on.
1. CHECK POWER SUPPLY CIRCUIT FOR UNIFIED METER AND A/C AMP.
1. Disconnect unified meter and A/C amp. connector.
2. Check voltage between unified meter and A/C amp. harness connector M56 terminals 21, 22 and 35, unified meter and A/C
amp. harness connector M57 terminal 46 and ground.
OK or NG
OK >> GO TO 2.
NG >> Check 10A and 15A fuses [Nos. 6, 10, 11, 12 and 19, located in the fuse block (J/B)]. Refer to PG-
80, "FUSE BLOCK - JUNCTION BOX (J/B)" .
If fuses are OK, check harness for open circuit. Repair or replace if necessary.
If fuses are NG, check harness for short circuit and replace fuse.
SJIA1583E
RJIA1983E
Terminals Ignition switch position
(+)
( − )OFFACC ON
Unified
meter and
A/C amp.
connector Terminal No.
M56 21
Ground Battery
voltage Battery
voltage Battery
voltage
M56 22 Approx. 0 V Approx. 0 V Battery
voltage
M56 35 Approx. 0 V Battery
voltage Battery
voltage
M57 46 Approx. 0 V Battery
voltage Battery
voltage
RJIA1984E