Downloaded from www.Manualslib.com manuals search engine 7B-50 Air Conditioning System: Automatic Type
Not Using SUZUKI Scan Tool
NOTE
In case of malfunction of temperature
selector, blower speed selector and air flow
selector, DTC can not be checked by the
following procedure. Use SUZUKI scan tool
for DTC check.
1) Light over sunload sensor vertically with an
incandescent light of approximately 100 W apart
from about 100 mm (3.94 in.).
NOTE
If sunload sensor is not lighted over with an
incandescent light, DTC of sunload sensor is
detected as current DTC even though there is
not any malfunction.
2) Set the following selectors to specified positions
below respectively with ignition switch off position.
• Temperature selector (1) is maximum cool
position
• Blower speed selector (2) is OFF position
• Air flow selector (3) is AUTO position
3) While pressing A/C switch (4) and air intake selector
(5) simultaneously, turn ignition switch to ON
position.
4) Wait for about 5 seconds (start of diagnosis).
5) Read flashing pattern of “FRE” (6) and “REC” (7)
indicator lights which represents DTC and write it
down.
NOTE
• When 2 or more current DTCs are
detected, only DTC having the highest
priority is indicated. Therefore, after
troubleshooting the malfunction, DTC
check has to be performed again to see if
any other DTC(s) is detected.
• Pressing “A/C” switch alternates display
of current DTC and history DTC. “A/C”
indicator light (8) remains off when display
is in current DTC mode and it lights up
when display is in history DTC mode.
• When a history DTC is indicated while 2 or
more history DTCs are detected, it is
possible to have other history DTC(s)
stored in HVAC control module displayed
by pressing the air intake selector.
Example: When inside air temperature sensor
circuit malfunction (Open) is set
Example: When VSS signal failure (Data error) is
set
6) After completing above check, turn ignition switch to
“OFF” position.
[A]: “REC” indicator light L: OFF
[B]: “FRE” indicator light a. About 0.5 seconds
H: ON b. About 2 seconds
[A]: “REC” indicator light a. About 0.5 seconds
[B]: “FRE” indicator light b. About 3 seconds
H: ON c. About 1.5 seconds
L: OFF
123
458
6
7I5RW0A722005-01
[A]
[B]H
L
H
L [B]
[A]
ab
aI5RW0A722006-02
[A]
[B]H
L
H
L [B]
[A]
ab
aaaa
c
I5RW0A722025-01
Downloaded from www.Manualslib.com manuals search engine 7B-52 Air Conditioning System: Automatic Type
DTC TableS6RW0D7224006
CAUTION!
Be sure to perform “Air Conditioning System Check” before starting diagnosis.
NOTE
• History DTC is such DTC which HVAC control module saves in its memory when it detects current
DTC for 60 seconds or more continuously.
• DTC B1504, B1541, B1546, B1570 and B1571 are displayed as a current DTC only when a current
malfunction is detected.
• When HVAC control module detects DTC B1513 and B1514, both current and history DTCs are
displayed at the same time.
DTC No.
(displayed
on SUZUKI
scan tool)Detection itemDTC (indicated on
HVAC control
module)
Condition when trouble detected (DTC is
determined when following condition detected)“A/C”
indicator
light Indicated
by “REC”
indicator
lightIndicated
by “FRE”
indicator
light
) B1502Inside Air
Temperature
Sensor Circuit
Malfunction21Signal voltage of inside air temperature sensor is
higher than specification.Flashed
22Signal voltage of inside air temperature sensor is
lower than specification.Flashed
) B1503Evaporator
Temperature
Sensor Circuit
Malfunction31Signal voltage of evaporator temperature sensor is
higher than specification. Flashed
32Signal voltage of evaporator temperature sensor is
lower than specification.Flashed
) B1504Sun load Sensor
Circuit
Malfunction41• Signal voltage of sun load sensor is higher than
specification.
• Without sunlight.—
42Signal voltage of sun load sensor is lower than
specification.Flashed
) B1511Temperature
Control Actuator
(Position Sensor)
and/or Its Circuit
Malfunction61Signal voltage of position sensor included in
temperature control actuator is higher than
specification.Flashed
62Signal voltage of position sensor included in
temperature control actuator is lower than
specification.Flashed
) B1512Air Flow Control
Actuator
(Position Sensor)
and/or Its Circuit
Malfunction71Signal voltage of position sensor included in airflow
control actuator is higher than specification. Flashed
72Signal voltage of position sensor included in airflow
control actuator is lower than specification.Flashed
) B1513Temperature
Control Actuator
(Motor) and/or Its
Circuit
Malfunction63
Motor of temperature control actuator is not
operated more than specified time.Flashed
) B1514Air Flow Control
Actuator (Motor)
and/or Its Circuit
Malfunction73Motor of air flow control actuator is not operated
more than specified time.Flashed
) B1520Temperature
Selector
Malfunction15 1Signal voltage of temperature selector in HVAC
control module is higher than specification.Flashed
15 2Signal voltage of temperature selector in HVAC
control module is lower than specification.Flashed