TROUBLE DIAGNOSIS
LAN-71
[CAN]
C
D
E
F
G
H
I
J
L
MA
B
LAN
Revision: June 20062007 Versa
Malfunction Area ChartUKS005WH
MAIN LINE
BRANCH LINE
SHORT CIRCUIT
Malfunction Area Reference
Main line between data link connector and TCMLAN-72, "
Main Line Between Data Link Connector and TCM"
Main line between data link connector and ABS actuator and
electric unit (control unit)LAN-73, "Main Line Between Data Link Connector and ABS
Actuator and Electric Unit (Control Unit)"
Malfunction Area Reference
ECM branch line circuit LAN-74, "
ECM Branch Line Circuit"
BCM branch line circuit LAN-74, "BCM Branch Line Circuit"
Data link connector branch line circuit LAN-75, "Data Link Connector Branch Line Circuit"
EPS control unit branch line circuit LAN-76, "EPS Control Unit Branch Line Circuit"
Intelligent Key unit branch line circuit LAN-76, "Intelligent Key Unit Branch Line Circuit"
Combination meter branch line circuit LAN-77, "Combination Meter Branch Line Circuit"
ABS actuator and electric unit (control unit) branch line circuit LAN-78, "ABS Actuator and Electric Unit (Control Unit) Branch
Line Circuit"
TCM branch line circuitLAN-78, "TCM Branch Line Circuit"
IPDM E/R branch line circuit LAN-79, "IPDM E/R Branch Line Circuit"
Malfunction Area Reference
CAN communication circuitLAN-80, "
CAN Communication Circuit"
LAN-76
[CAN]
TROUBLE DIAGNOSIS
Revision: June 20062007 Versa
EPS Control Unit Branch Line CircuitUKS005WM
INSPECTION PROCEDURE
1. CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the EPS control unit for damage, bend and loose connection (unit
side and connector side).
OK or NG
OK >> GO TO 2.
NG >> Repair the terminal and connector.
2. CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of EPS control unit.
2. Check the resistance between the EPS control unit harness connector terminals.
OK or NG
OK >> GO TO 3.
NG >> Repair the EPS control unit branch line.
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of EPS control unit. Refer to STC-9, "
Wiring Diagram — EPS
—" .
OK or NG
OK >>Present error: Replace the EPS control unit. Refer to PS-9, "Removal and Installation" .
Past error: Error was detected in the EPS control unit branch line.
NG >> Repair the power supply and the ground circuit.
Intelligent Key Unit Branch Line CircuitUKS005WN
INSPECTION PROCEDURE
1. CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the Intelligent Key unit for damage, bend and loose connection
(unit side and connector side).
OK or NG
OK >> GO TO 2.
NG >> Repair the terminal and connector.
EPS control unit harness connector
Resistance (Ω)
Connector No. Terminal No.
M53 9 16 Approx. 54 – 66
TROUBLE DIAGNOSIS
LAN-77
[CAN]
C
D
E
F
G
H
I
J
L
MA
B
LAN
Revision: June 20062007 Versa
2. CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of Intelligent Key unit.
2. Check the resistance between the Intelligent Key unit harness connector terminals.
OK or NG
OK >> GO TO 3.
NG >> Repair the Intelligent Key unit branch line.
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of Intelligent Key unit. Refer to BL-123, "
Power Supply and
Ground Circuit Check" .
OK or NG
OK >>Present error: Replace the Intelligent Key unit. Refer to BL-160, "Removal and Installation of
Intelligent Key Unit" .
Past error: Error was detected in the Intelligent Key unit branch line.
NG >> Repair the power supply and the ground circuit.
Combination Meter Branch Line CircuitUKS005WO
INSPECTION PROCEDURE
1. CHECK CONNECTOR
1. Turn the ignition switch OFF.
2. Disconnect the battery cable from the negative terminal.
3. Check the terminals and connectors of the combination meter for damage, bend and loose connection
(unit side and connector side).
OK or NG
OK >> GO TO 2.
NG >> Repair the terminal and connector.
2. CHECK HARNESS FOR OPEN CIRCUIT
1. Disconnect the connector of combination meter.
2. Check the resistance between the combination meter harness connector terminals.
OK or NG
OK >> GO TO 3.
NG >> Repair the combination meter branch line.
3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Check the power supply and the ground circuit of combination meter. Refer to DI-17, "
Power Supply and
Ground Circuit Inspection" .
OK or NG
OK >>Present error: Replace the combination meter. Refer to DI-23, "Removal and Installation" .
Past error: Error was detected in the combination meter branch line.
NG >> Repair the power supply and the ground circuit.
Intelligent Key unit harness connector
Resistance (Ω)
Connector No. Terminal No.
M52 2 3 Approx. 54 – 66
Combination meter harness connector
Resistance (Ω)
Connector No. Terminal No.
M24 1 2 Approx. 54 – 66
LT-2Revision: June 20062007 Versa Daytime Light Control Does Not Operate Properly
(High Beam Headlamps Operate Properly) ............ 35
Aiming Adjustment .................................................. 37
PREPARATION BEFORE ADJUSTING .............. 37
LOW BEAM AND HIGH BEAM ........................... 37
ADJUSTMENT USING AN ADJUSTMENT
SCREEN (LIGHT/DARK BORDERLINE) ............ 38
Bulb Replacement .................................................. 39
HEADLAMP (HIGH/LOW) ................................... 39
PARKING (CLEARANCE) LAMP ......................... 39
FRONT TURN SIGNAL LAMP ............................ 39
Removal and Installation ........................................ 39
REMOVAL ........................................................... 39
INSTALLATION .................................................... 39
Disassembly and Assembly .................................... 40
DISASSEMBLY ................................................... 40
ASSEMBLY ......................................................... 40
FRONT FOG LAMP .................................................. 41
Component Parts and Harness Connector Location ... 41
System Description ................................................. 41
OUTLINE ............................................................. 41
FOG LAMP OPERATION .................................... 42
COMBINATION SWITCH READING FUNCTION ... 42
EXTERIOR LAMP BATTERY SAVER CONTROL ... 42
CAN Communication System Description .............. 42
Wiring Diagram — F/FOG — .................................. 43
Terminals and Reference Values for BCM .............. 45
Terminals and Reference Values for IPDM E/R ...... 45
How to Proceed With Trouble Diagnosis ................ 45
Preliminary Check .................................................. 45
CHECK POWER SUPPLY AND GROUND CIR-
CUIT FOR BCM ................................................... 45
CHECK POWER SUPPLY AND GROUND CIR-
CUIT FOR IPDM E/R ........................................... 45
CONSULT-II Function (BCM) .................................. 45
CONSULT-II Function (IPDM E/R) .......................... 45
Front Fog lamps Do Not Illuminate (Both Sides) .... 45
Front Fog Lamp Does Not Illuminate (One Side) ... 48
Aiming Adjustment .................................................. 49
Bulb Replacement .................................................. 49
Removal and Installation ........................................ 50
REMOVAL ........................................................... 50
INSTALLATION .................................................... 50
TURN SIGNAL AND HAZARD WARNING LAMPS ... 51
Component Parts and Harness Connector Location ... 51
System Description ................................................. 51
TURN SIGNAL OPERATION ............................... 51
HAZARD LAMP OPERATION ............................. 52
REMOTE KEYLESS ENTRY SYSTEM OPERA-
TION .................................................................... 53
COMBINATION SWITCH READING FUNCTION ... 53
CAN Communication System Description .............. 53
Schematic ............................................................... 54
Wiring Diagram — TURN — ................................... 55
Terminals and Reference Values for BCM .............. 59
How to Proceed With Trouble Diagnosis ................ 59
Preliminary Check .................................................. 59
CHECK POWER SUPPLY AND GROUND CIR-
CUIT FOR BCM ................................................... 59CONSULT-II Function (BCM) ..................................59
Turn Signals Do Not Operate ..................................59
Front Turn Signal Lamp Does Not Operate ............59
Rear Turn Signal Lamp Does Not Operate .............60
Hazard Warning Lamp Does Not Operate But Turn
Signal Lamp Operates ............................................62
Turn Signal Indicator Lamp Does Not Operate .......63
Bulb Replacement of Front Turn Signal Lamp ........64
Bulb Replacement of Rear Turn Signal Lamp .........64
Removal and Installation of Front Turn Signal Lamp ...64
Removal and Installation of Rear Turn Signal Lamp ...64
LIGHTING AND TURN SIGNAL SWITCH ................65
Removal and Installation .........................................65
REMOVAL ............................................................65
INSTALLATION ....................................................65
HAZARD SWITCH .....................................................66
Removal and Installation .........................................66
REMOVAL ............................................................66
INSTALLATION ....................................................66
COMBINATION SWITCH ..........................................67
Wiring Diagram — COMBSW — ............................67
Combination Switch Reading Function ...................68
Terminals and Reference Values for BCM ..............68
CONSULT-II Function (BCM) ..................................68
Combination Switch Inspection ...............................68
Removal and Installation .........................................70
STOP LAMP ..............................................................71
Wiring Diagram — STOP/L — ................................71
Bulb Replacement of High-Mounted Stop Lamp .....72
Bulb Replacement of Rear Combination Lamp for
Stop Lamp ...............................................................72
Removal and Installation of High-Mounted Stop
Lamp .......................................................................72
REMOVAL ............................................................72
INSTALLATION ....................................................72
Removal and Installation of Rear Combination
Lamp for Stop Lamp ................................................72
BACK-UP LAMP .......................................................73
Wiring Diagram — BACK/L — ................................73
Bulb Replacement ...................................................74
Removal and Installation .........................................74
PARKING, LICENSE PLATE AND TAIL LAMPS ......75
Component Parts and Harness Connector Location ...75
System Description .................................................75
OPERATION BY LIGHTING SWITCH .................75
COMBINATION SWITCH READING FUNCTION ...76
EXTERIOR LAMP BATTERY SAVER CONTROL ...76
CAN Communication System Description ..............76
Schematic ...............................................................77
Wiring Diagram — TAIL/L — ...................................78
Terminals and Reference Values for BCM ..............81
Terminals and Reference Values for IPDM E/R ......81
How to Proceed With Trouble Diagnosis ................81
Preliminary Check ...................................................81
CHECK POWER SUPPLY AND GROUND CIR-
CUIT FOR BCM ...................................................81
CHECK POWER SUPPLY AND GROUND CIR-
CUIT FOR IPDM E/R ...........................................81
CONSULT-II Function (BCM) ..................................81
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-53
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
to rear combination lamp LH terminal 1
through grounds B7 and B19,
to rear combination lamp RH terminal 1
through grounds B117, B132 and D402.
The BCM also supplies input to combination meter across the CAN communication lines. This input is pro-
cessed by unified meter control unit in combination meter, which in turn supplies ground to the left and right
turn signal indicator lamps.
With power and input supplied, BCM controls flashing of hazard warning lamps.
REMOTE KEYLESS ENTRY SYSTEM OPERATION
Power is supplied at all times
through 40A fusible link (letter g , located in fuse, fusible link and relay box)
to BCM terminal 70,
through 10A fuse [No. 13, located in fuse block (J/B)]
to combination meter terminal 27.
Ground is supplied
to BCM terminal 67 and
to combination meter terminals 21, 22 and 23
through grounds M57 and M61.
When the remote keyless entry system is triggered by input from the keyfob, the BCM supplies power
through BCM terminal 60
to front combination lamp LH terminal 4 and
to rear combination lamp LH terminal 6,
through BCM terminal 61
to front turn signal lamp RH terminal 4 and
to rear combination lamp RH terminal 6.
Ground is supplied
to front combination lamp LH and RH terminals 5
through grounds E15 and E24,
to rear combination lamp LH terminal 1
through grounds B7 and B19,
to rear combination lamp RH terminal 1
through grounds B117, B132 and D402.
The BCM also supplies input to combination meter via the CAN communication lines. This input is processed
by the unified meter control unit in combination meter, which in turn supplies ground to the left and right turn
signal indicator lamps.
With power and ground supplied, BCM controls flashing of hazard warning lamps when keyfob is used to acti-
vate remote keyless entry system.
COMBINATION SWITCH READING FUNCTION
Refer toBCS-3, "COMBINATION SWITCH READING FUNCTION" .
CAN Communication System DescriptionEKS00HY1
Refer to LAN-4, "CAN Communication System" .
INTERIOR ROOM LAMP
LT-91
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
INTERIOR ROOM LAMPPFP:26410
Component Parts and Harness Connector LocationEKS00HZJ
System DescriptionEKS00HZK
When room lamp switch is in DOOR position, room lamp ON/OFF is controlled by timer according to signals
from switches including key switch, front door switch LH, unlock signal from keyfob, door lock and unlock
switch, key cylinder lock and unlock switch, ignition switch.
When room lamp turns ON, there is a gradual brightening over 1 second.
When room lamp turns OFF, there is a gradual dimming over 1 second.
Interior room lamp timer is controlled by BCM (body control module).
Interior room lamp timer control settings can be changed with CONSULT-II.
POWER SUPPLY AND GROUND
Power is supplied at all times (without Intelligent Key system)
through 10A fuse [No. 14, located in fuse block (J/B)]
to key switch and key lock solenoid terminal 2,
through 10A fuse [No. 8, located in fuse block (J/B)]
to BCM terminal 57,
through 40A fusible link (letter g , located in fuse and fusible link box)
to BCM terminal 70.
Power is supplied at all times (with Intelligent Key system)
through 10A fuse (No. 31, located in fuse and fusible link box)
to key switch and ignition knob switch terminals 2 and 4,
through 10A fuse [No. 8, located in fuse block (J/B)]
to BCM terminal 57,
through 40A fusible link (letter g , located in fuse and fusible link box)
to BCM terminal 70.
When key is inserted in the key switch and key lock solenoid, power is supplied (without Intelligent Key sys-
tem)
through key switch and key lock solenoid terminal 1
to BCM terminal 37.
1. BCM M18, M19 and M20 (view with
glove box removed)2. Key switch and key lock solenoid
(without Intelligent Key) M273. Key switch and ignition knob switch
(with Intelligent Key) M73
4. Front door switch LH B8 and RH
B1085. Rear door switch LH B6 and RH
B1166. Front door key cylinder switch LH
D14
WKIA5545E
LT-92
INTERIOR ROOM LAMP
Revision: June 20062007 Versa
When key is inserted in the key switch and ignition knob switch, power is supplied (with Intelligent Key system)
through key switch and ignition knob switch terminal 1
to BCM terminal 37.
When ignition knob switch is pushed, power is supplied (with Intelligent Key system)
through key switch and ignition knob switch terminal 3
to Intelligent Key unit terminal 27.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM terminal 38.
Ground is supplied
to BCM terminal 67
through grounds M57 and M61.
When front door LH is opened, ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through case ground of front door switch LH.
When front door RH is opened, ground is supplied
to BCM terminal 12
through front door switch RH terminal 2
through case ground of front door switch RH.
When rear door LH is opened, ground is supplied
to BCM terminal 48
through rear door switch LH terminal 1
through case ground of rear door switch LH.
When rear door RH is opened, ground is supplied
to BCM terminal 13
through rear door switch RH terminal 1
through case ground of rear door switch RH.
When back door is opened, ground is supplied
to BCM terminal 43
through back door lock assembly (back door switch) terminal 3
through back door lock assembly (back door switch) terminal 4
through grounds B117, B132 and D402.
When front door LH is unlocked by front door key cylinder switch LH, the BCM receives a ground signal
to BCM terminal 7
through front door key cylinder switch LH terminal 3
through front door key cylinder switch LH terminal 2
through grounds M57 and M61.
When a signal, or combination of signals is received by BCM, ground is supplied
to room lamp terminal 2
through map lamp terminals 5 and 2 (with map lamp)
through BCM terminal 63.
With power and ground supplied, the interior room lamp illuminates.
SWITCH OPERATION
When map lamp switch is ON (with map lamp), ground is supplied
through grounds M57 and M61.
to map lamp terminal 1
Power is supplied
INTERIOR ROOM LAMP
LT-93
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: June 20062007 Versa
through BCM terminal 56
to map lamp terminal 4.
When interior room lamp switch is ON, ground is supplied
to interior room lamp terminal 1
through map lamp (with map lamp) terminal 7
through map lamp (with map lamp) terminal 1
through grounds M57 and M61.
Power is supplied
through BCM terminal 56
through map lamp (with map lamp) terminal 4
through map lamp (with map lamp) terminal 6
to room lamp terminal 3.
INTERIOR ROOM LAMP TIMER OPERATION
Without Intelligent Key System
When room lamp switch is in DOOR position, and when all conditions below are met, BCM performs timer
control (maximum 30 seconds) for room lamp ON/OFF.
In addition, when the interior room lamp turns ON or OFF there is gradual brightening or dimming over 1 sec-
ond.
Power is supplied
through 10A fuse [No. 14, located in fuse block (J/B)]
to key switch and key lock solenoid terminal 2.
When the key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM termi-
nal 37.
When front door key cylinder switch LH is unlocked, ground is supplied
to BCM terminal 7
through front door key cylinder switch LH terminal 3
through front door key cylinder switch LH terminal 2
through grounds M57 and M61.
At the time that front door LH is opened, BCM detects that front door LH is unlocked. It determines that interior
room lamp timer operation condition is met, and turns the room lamp ON for 30 seconds.
When key is in ignition key cylinder (key switch ON),
Power is supplied
through key switch and key lock solenoid terminal 1
to BCM terminal 37.
When key is removed from key switch and key lock solenoid (key switch OFF), the power supply to BCM ter-
minal 37 is terminated. BCM detects that key has been removed, determines that interior room lamp timer
conditions are met, and turns the room lamp ON for 30 seconds.
When front door LH opens → closes, and the key is not inserted in the key switch and key lock solenoid (key
switch OFF), voltage at BCM terminal 47 changes between 0V (door open) → 12V (door closed). The BCM
determines that conditions for room lamp operation are met and turns the room lamp ON for 30 seconds.
Interior room lamp timer control is canceled under the following conditions:
Front door LH is locked (locked front door key cylinder switch LH).
Front door LH is opened (front door switch LH).
Ignition switch ON.
With Intelligent Key System
When the room lamp switch is in DOOR position, and when all conditions below are met, BCM performs timer
control (maximum 30 second) for room lamp ON/OFF.
In addition, when interior room lamp turns ON or OFF there is gradual brightening or dimming over 1 second.
Power is supplied
through 10A fuse (No. 31, located in fuse and fusible link box)
to key switch and ignition knob switch terminals 2 and 4.