2006 INFINITI FX35 turn signal

[x] Cancel search: turn signal

Page 1535 of 4462

INFINITI FX35 2006  Service Manual POWER SUPPLY AND GROUND CIRCUIT EC-151
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
4. CHECK GROUND CONNECTIONS 
1. Turn ignition switch OFF. 
2. Loosen and r

Page 1546 of 4462

INFINITI FX35 2006  Service Manual EC-162
[VQ35DE]
DTC P0011, P0021 IVT CONTROL
Revision: 2006 December 2006 FX35/FX45
On Board Diagnosis LogicNBS003MQ
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode.
DTC

Page 1549 of 4462

INFINITI FX35 2006  Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER EC-165
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATERPFP:2

Page 1554 of 4462

INFINITI FX35 2006  Service Manual EC-170
[VQ35DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2006 December 2006 FX35/FX45
Specification data are reference values and are measured between each terminal and ground. 
Pu

Page 1555 of 4462

INFINITI FX35 2006  Service Manual DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER EC-171
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
2. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIR

Page 1563 of 4462

INFINITI FX35 2006  Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER EC-179
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
2. CHECK HO2S2 POWER SUPPLY CIRCUIT 
1. Disconnect heated oxyg

Page 1565 of 4462

INFINITI FX35 2006  Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE EC-181
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
DTC P0075, P0081 IVT CONTROL SOLENOID VALVEPFP:23796
Component

Page 1567 of 4462

INFINITI FX35 2006  Service Manual DTC P0075, P0081 IVT CONTROL SOLENOID VALVE EC-183
[VQ35DE]
C 
D  E 
F 
G  H 
I 
J 
K  L 
M  A
EC 
Revision: 2006 December 2006 FX35/FX45
Specification data are reference values and are measured betwe