![INFINITI FX35 2006 Service Manual EC-162
[VQ35DE]
DTC P0011, P0021 IVT CONTROL
Revision: 2006 December 2006 FX35/FX45
On Board Diagnosis LogicNBS003MQ
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode.
DTC INFINITI FX35 2006 Service Manual EC-162
[VQ35DE]
DTC P0011, P0021 IVT CONTROL
Revision: 2006 December 2006 FX35/FX45
On Board Diagnosis LogicNBS003MQ
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode.
DTC](/manual-img/42/57019/w960_57019-1545.png)
EC-162
[VQ35DE]
DTC P0011, P0021 IVT CONTROL
Revision: 2006 December 2006 FX35/FX45
On Board Diagnosis LogicNBS003MQ
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode.
DTC Confirmation ProcedureNBS003MR
CAUTION:
Always drive at a safe speed.
NOTE:
If DTC P0011 or P0021 is displayed with DTC P0075 or P0081, first perform trouble diagnosis for
DTC P0075 or P0081. Refer to EC-181, "
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE" .
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait
at least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10V and 16V at
idle.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
2. Start engine and warm it up to the normal operating tempera- ture.
3. Maintain the following conditions for at least 6 consecutive sec- onds. Hold the accelerator pedal as steady as possible.
4. Let engine idle for 10 seconds.
5. If 1st trip DTC is detected, go to EC-163, "
Diagnostic Procedure" .
If 1st trip DTC is not detected, go to next step.
6. Maintain the following conditions for at least 20 consecutive seconds.
DTC No. Trouble diagnosis
name Detecting condition Possible cause
P0011
0011
(Bank 1)
Intake valve timing
control performance There is a gap between angle of target and
phase-control angle degree.
Crankshaft position sensor (POS)
Camshaft position sensor (PHASE)
Intake valve control solenoid valve
Accumulation of debris to the signal pick-up
portion of the camshaft
Timing chain installation
Foreign matter caught in the oil groove for
intake valve timing control
P0021
0021
(Bank 2)
Detected items Engine operating condition in fail-safe mode
Intake valve timing control The signal is not energized to the solenoid valve and the valve control does not function.
VHCL SPEED SE 100 - 120 km/h (63 - 75 MPH)
ENG SPEED 1,200 - 2,000 rpm
COOLAN TEMP/S More than 60 °C (140 °F)
B/FUEL SCHDL More than 7.3 msec
Selector lever D position
ENG SPEED 1,700 - 3,175 rpm (A constant rotation is maintained.)
COOLAN TEMP/S 70 - 105 °C (158 - 221 °F)
Selector lever 1st or 2nd position
Driving location uphill Driving vehicle uphill
(Increased engine load will help maintain the driving
conditions required for this test.)
PBIB0164E
![INFINITI FX35 2006 Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER EC-173
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC P0037, P0038, P0057, P0058 HO2S2 HEATERPFP:226A0
Descripti INFINITI FX35 2006 Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER EC-173
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC P0037, P0038, P0057, P0058 HO2S2 HEATERPFP:226A0
Descripti](/manual-img/42/57019/w960_57019-1556.png)
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER EC-173
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC P0037, P0038, P0057, P0058 HO2S2 HEATERPFP:226A0
DescriptionNBS003MV
SYSTEM DESCRIPTION
The ECM performs ON/OFF control of the heated oxygen sensor 2 heater corresponding to the engine speed,
amount of intake air and engine coolant temperature.
OPERATION
CONSULT-II Reference Value in Data Monitor ModeNBS003MW
Specification data are reference values.
On Board Diagnosis LogicNBS003MX
Sensor Input signal to ECM ECM function Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS) Engine speed
Heated oxygen sensor 2
heater control Heated oxygen sensor 2 heater
Engine coolant temperature sensor Engine coolant temperature
Mass air flow sensor Amount of intake air
Engine speed rpm Heated oxygen sensor 2 heater
Above 3,600 OFF
Below 3,600 rpm after the following conditions are met.
Engine: After warming up
Keeping the engine speed between 3,500 and 4,000 rpm for 1
minute and at idle for 1 minute under no load ON
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 HTR (B1)
HO2S2 HTR (B2)
Engine speed: Below 3,600 rpm after the following conditions are met.
–Engine: After warming up
–Keeping the engine speed between 3,500 and 4,000 rpm for 1 minute and
at idle for 1 minute under no load ON
Engine speed: Above 3,600 rpm OFF
DTC No.
Trouble diagnosis
name DTC detecting condition Possible cause
P0037
0037
(Bank 1) Heated oxygen
sensor 2 heater
control circuit low The current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM
through the heated oxygen sensor 2 heater.)
Harness or connectors
(Heated oxygen sensor 2 heater circuit is
open or shorted.)
Heated oxygen sensor 2 heater
P0057
0057
(Bank 2)
P0038
0038
(Bank 1) Heated oxygen
sensor 2 heater
control circuit high The current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to
ECM through the heated oxygen sensor 2
heater.)
Harness or connectors
(Heated oxygen sensor 2 heater circuit is
shorted.)
Heated oxygen sensor 2 heater
P0058
0058
(Bank 2)
![INFINITI FX35 2006 Service Manual EC-210
[VQ35DE]
DTC P0117, P0118 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
DTC P0117, P0118 ECT SENSORPFP:22630
Component DescriptionNBS003NR
The engine coolant temperature (ECT) sensor is use INFINITI FX35 2006 Service Manual EC-210
[VQ35DE]
DTC P0117, P0118 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
DTC P0117, P0118 ECT SENSORPFP:22630
Component DescriptionNBS003NR
The engine coolant temperature (ECT) sensor is use](/manual-img/42/57019/w960_57019-1593.png)
EC-210
[VQ35DE]
DTC P0117, P0118 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
DTC P0117, P0118 ECT SENSORPFP:22630
Component DescriptionNBS003NR
The engine coolant temperature (ECT) sensor is used to detect the
engine coolant temperature. The sensor modifies a voltage signal
from the ECM. The modified signal returns to the ECM as the engine
coolant temperature input. The sensor uses a thermistor which is
sensitive to the change in temperature. The electrical resistance of
the thermistor decreases as temperature increases.
*: This data is reference values and is measured between ECM terminal 73 (Engine
coolant temperature sensor) and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
On Board Diagnosis LogicNBS003NS
These self-diagnoses have the one trip detection logic.
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode and the MIL lights up.
SEF594K
Engine coolant temperature
° C ( °F) Voltage* V Resistance k
Ω
-10 (14) 4.4 7.0 - 11.4 20 (68) 3.5 2.1 - 2.9
50 (122) 2.2 0.68 - 1.00
90 (194) 0.9 0.236 - 0.260
SEF012P
DTC No. Trouble Diagnosis
Name DTC Detecting Condition Possible Cause
P0117
0117 Engine coolant tem-
perature sensor cir-
cuit low input An excessively low voltage from the sensor is
sent to ECM.
Harness or connectors
(Engine coolant temperature sensor circuit is
open or shorted.)
Engine coolant temperature sensor
P0118
0118 Engine coolant tem-
perature sensor cir-
cuit high input An excessively high voltage from the sensor is
sent to ECM.
Detected items Engine operating condition in fail-safe mode
Engine coolant temper- ature sensor circuit Engine coolant temperature will be determined by ECM based on the time after turning ignition switch ON
or START.
CONSULT-II displays the engine coolant temperature decided by ECM.
Condition Engine coolant temperature decided
(CONSULT-II display)
Just as ignition switch is turned ON or START 40 °C (104 °F)
More than approx. 4 minutes after ignition ON or
START 80
°C (176 °F)
Except as shown above 40 - 80
°C (104 - 176 °F)
(Depends on the time)
When the fail-safe system for engine coolant temperature sensor is activated, the cooling fan operates
while engine is running.
![INFINITI FX35 2006 Service Manual DTC P0117, P0118 ECT SENSOR EC-213
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS003NV
1. CHECK GROUND CONNECTIONS
1. Turn ignition swi INFINITI FX35 2006 Service Manual DTC P0117, P0118 ECT SENSOR EC-213
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS003NV
1. CHECK GROUND CONNECTIONS
1. Turn ignition swi](/manual-img/42/57019/w960_57019-1596.png)
DTC P0117, P0118 ECT SENSOR EC-213
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
Diagnostic ProcedureNBS003NV
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground screw on the body. Refer to EC-154, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. CHECK ECT SENSOR POWER SUPPLY CIRCUIT
1. Disconnect engine coolant temperature (ECT) sensor harness connector.
2. Turn ignition switch ON.
3. Check voltage between ECT sensor terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2625E
PBIB1563E
Voltage: Approximately 5V
PBIB0080E
![INFINITI FX35 2006 Service Manual EC-214
[VQ35DE]
DTC P0117, P0118 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
3. CHECK ECT SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connec INFINITI FX35 2006 Service Manual EC-214
[VQ35DE]
DTC P0117, P0118 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
3. CHECK ECT SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connec](/manual-img/42/57019/w960_57019-1597.png)
EC-214
[VQ35DE]
DTC P0117, P0118 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
3. CHECK ECT SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECT sensor terminal 2 and ECM terminal 67. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK ENGINE COOLANT TEMPERATURE SENSOR
Refer to EC-214, "
Component Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Replace engine coolant temperature sensor.
5. CHECK INTERMITTENT INCIDENT
Refer to EC-148, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>> INSPECTION END
Component InspectionNBS003NW
ENGINE COOLANT TEMPERATURE SENSOR
Check resistance between engine coolant temperature sensor termi-
nals 1 and 2 as shown in the figure.
If NG, replace engine coolant temperature sensor.
Removal and InstallationNBS003NX
ENGINE COOLANT TEMPERATURE SENSOR
Refer to CO-27, "WATER INLET AND THERMOSTAT ASSEMBLY" .
Continuity should exist.
PBIB2005E
Engine coolant temperature
°C ( °F) Resistance k Ω
20 (68) 2.1 - 2.9
50 (122) 0.68 - 1.00
90 (194) 0.236 - 0.260
SEF012P
![INFINITI FX35 2006 Service Manual EC-222
[VQ35DE]
DTC P0125 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
DTC P0125 ECT SENSORPFP:22630
Component DescriptionNBS003O6
NOTE:
If DTC P0125 is displayed with P0117 or P0118, first perf INFINITI FX35 2006 Service Manual EC-222
[VQ35DE]
DTC P0125 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
DTC P0125 ECT SENSORPFP:22630
Component DescriptionNBS003O6
NOTE:
If DTC P0125 is displayed with P0117 or P0118, first perf](/manual-img/42/57019/w960_57019-1605.png)
EC-222
[VQ35DE]
DTC P0125 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
DTC P0125 ECT SENSORPFP:22630
Component DescriptionNBS003O6
NOTE:
If DTC P0125 is displayed with P0117 or P0118, first perform the trouble diagnosis for DTC P0117 or
P0118. Refer to EC-210, "
DTC P0117, P0118 ECT SENSOR" .
The engine coolant temperature (ECT) sensor is used to detect the
engine coolant temperature. The sensor modifies a voltage signal
from the ECM. The modified signal returns to the ECM as the engine
coolant temperature input. The sensor uses a thermistor which is
sensitive to the change in temperature. The electrical resistance of
the thermistor decreases as temperature increases.
*: This data is reference values and is measured between ECM terminal 73 (Engine
coolant temperature sensor) and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output
voltage. Doing so may result in damage to the ECM's transistor. Use a ground other than ECM termi-
nals, such as the ground.
On Board Diagnosis LogicNBS003O7
SEF594K
Engine coolant
temperature °C ( °F) Voltage* V Resistance k
Ω
20 (68) 3.5 2.1 - 2.9
50 (122) 2.2 0.68 - 1.00
90 (194) 0.9 0.236 - 0.260
SEF012P
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0125
0125 Insufficient engine cool-
ant temperature for
closed loop fuel control
Voltage sent to ECM from the sensor is not
practical, even when some time has passed
after starting the engine.
Engine coolant temperature is insufficient for
closed loop fuel control.
Harness or connectors
(High resistance in the circuit)
Engine coolant temperature sensor
Thermostat
![INFINITI FX35 2006 Service Manual DTC P0125 ECT SENSOR EC-223
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS003O8
CAUTION:
Be careful not to overheat engine.
NOTE INFINITI FX35 2006 Service Manual DTC P0125 ECT SENSOR EC-223
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS003O8
CAUTION:
Be careful not to overheat engine.
NOTE](/manual-img/42/57019/w960_57019-1606.png)
DTC P0125 ECT SENSOR EC-223
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2006 December 2006 FX35/FX45
DTC Confirmation ProcedureNBS003O8
CAUTION:
Be careful not to overheat engine.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Check that “COOLAN TEMP/S” is above 10 °C (50 °F).
If it is above 10 °C (50 °F), the test result will be OK.
If it is below 10 °C (50 °F), go to following step.
4. Start engine and run it for 65 minutes at idle speed. If “COOLAN TEMP/S” increases to more than 10 °C (50 °F)
within 65 minutes, stop engine because the test result will
be OK.
5. If 1st trip DTC is detected, go to EC-223, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Diagnostic ProcedureNBS003O9
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground screw on the body. Refer to EC-154, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2. CHECK ENGINE COOLANT TEMPERATURE SENSOR
Refer to EC-224, "
Component Inspection" .
OK or NG
OK >> GO TO 3.
NG >> Replace engine coolant temperature sensor.
SEF174Y
PBIB2625E
![INFINITI FX35 2006 Service Manual EC-224
[VQ35DE]
DTC P0125 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
3. CHECK THERMOSTAT OPERATION
When the engine is cold [lower than 70 °C (158 °F)] condition, grasp lower radiator hose a INFINITI FX35 2006 Service Manual EC-224
[VQ35DE]
DTC P0125 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
3. CHECK THERMOSTAT OPERATION
When the engine is cold [lower than 70 °C (158 °F)] condition, grasp lower radiator hose a](/manual-img/42/57019/w960_57019-1607.png)
EC-224
[VQ35DE]
DTC P0125 ECT SENSOR
Revision: 2006 December 2006 FX35/FX45
3. CHECK THERMOSTAT OPERATION
When the engine is cold [lower than 70 °C (158 °F)] condition, grasp lower radiator hose and confirm the engine
coolant does not flow.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace thermostat. Refer to CO-27, "
WATER INLET AND THERMOSTAT ASSEMBLY"
.
4. CHECK INTERMITTENT INCIDENT
Refer to EC-148, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
Refer to EC-212, "
Wiring Diagram" .
>> INSPECTION END
Component InspectionNBS003OA
ENGINE COOLANT TEMPERATURE SENSOR
Check resistance between engine coolant temperature sensor termi-
nals 1 and 2 as shown in the figure.
If NG, replace engine coolant temperature sensor.
Removal and InstallationNBS003OB
ENGINE COOLANT TEMPERATURE SENSOR
Refer to CO-27, "WATER INLET AND THERMOSTAT ASSEMBLY" .
PBIB2005E
Engine coolant temperature °C ( °F) Resistance k Ω
20 (68) 2.1 - 2.9
50 (122) 0.68 - 1.00
90 (194) 0.236 - 0.260
SEF012P