Electrical system
The structure and parameter of the electrical system are shown in table 7.
Table 7 Structure And Parameter of Electrical System
No. Item Structure and Parameter
1 Power, starting and charging system
1.1 Lines Singe line system, voltage DC 12V, negative earth
1.2 Accumulator 55D26R maintenance free type, voltage 12V, 20 hours capacity 60Ah, storage
capacity 101min, low temperature starting current 475A
1.3 Starter 12V, 1.2kW
1.4 generator Internally furnished with adjustor type generator. 14V, 90A
2 Illumination and signal s ystem
2.1 Front illumination light
white, major high beam 60W,1 on the left and right respectively,
auxiliary high
beam 55W,1 on the left and right respectively, passing
lamp 55W,1 on the left and right respectively. Head light base center
height H: 920mm±20mm
2.2 Position light Front position lamp: white, 5W,1 on the left and right respectively.
Rear parking lights: red, 5W,1 on the left and right respectively.
2.3 turn light Amber。Front and rear turn light: 21W,1 on the left and right
respectively. Side turn light: 5W,1 on the left and right respectively,
2.4 Fog light Front fog light: white, 55W, 1 on the left and right respectively. Rear
fog light: red, LED,1 on the left and right respectively.
2.5 Brake light Red, 21W, 1 on the left and right respectively, high position brake light,
10W, 2 in the middle
2.6 License light White, 5W, 1 on the left and right respectively.
2.7 Backup light White, 21W, 1 on the left and right respectively.
2.8 Danger warning signal light All the turning signal lights, danger alarm switch control
2.9 Back repeating reflector Red, none triangle shape, forming combination light with the rear fog
light
2.10 Front, middle and back ceiling light
in the room White. Front indoor ceiling light: 10W, 2 pieces. Middle indoor ceiling
light: 10W, 1 piece. Back indoor ceiling lights: 5W, 1 piece
2.11 Cigar lighter illumination Blue, 3W, 1 piece
2.12 Ash tray illumination White, 3W, 1 piece
3 Meter system
3.1 Combined instrument Car speed odometer, engine speed indicator , water t emperature met er,
fuel gage
3.2 Indicator lamp Refer to the drawing
4 Auxiliary electrical system
4.1 Rain wiper system Front and rear rain wiper DC motor. Front rain wiper: four rods type,
electric drive three gears (high and low speed + adjustable interval),
scraper 2 pieces, 55W. Rear rain wiper: single arm type, electric drive
one gear, with 1 scraper plate, 21W
4.2 Defogging, defrosting device Front wind window hearing type, back wind window heating type
glass, switch control
4.3 Electric drive glass frame riser Drive side general control, independent control oh other windows and
doors
4.4 Central control lock With r emote control
4.5 Camborne power socket 12V, 2 pieces
4.6 Radio, CD and loudspeaker Stereo radio, six discs CD, four sound channels
Safety airbag-10
1. Extinguishments of safety airbag system alarm lamp
Troubleshooting
Extinguishments or normal-light of alarm lamp
NO . Troubleshooting item Description
1 T he warning la mp of safety a irbag
system is not displayed. Safety airbag system warns circuit failure
2 T he warning la mp of safety a irbag
system is light normally. Safety airbag system warns circuit failure or external
failure.
1 Extinguishments of safety airbag system alarm lamp
Test status Safety airbag system warns circuit failure.
Possible causes No voltage (fuse shutoff)
Combined instrument failure
Failure of wiring harness between instrument cluster and ECU unit
Diagnostic procedure
When first carry out failure test, joggle the wiring harness and plug to test whether there is periodical bad contact in the circuit, if
it so, please confirm whether the plug, terminal and wiring harness well connected and in good condition. If it is not any of previous
cases, operate according to the following steps.
Procedure Te s t Operation
Ye s Place the ignition switch in LOCK
position followed by next step
1 Test other wiring harness and instrument cluster
indicator lamp
·place the ignition switch in ON position
·light other alarm and indicator lamps No Test the instrument cluster power-supply
system and grounding s ystem (fuse), then
go to step 5.
Yes Next step
2 Bulb test
Warning:
Incorrect handling with the safety airbag system
units will cause the safety airbag’s improper
release and pretension of safety belt, which will
lead to serene accidents. Please read safety airbag
service warning before handling the safety airbag
units.
·Place the ignition switch in LOCK position。
·shut off accumulator negative line and keep the
status for at least 60 seconds.
·Remove the combined instrument.
Test the connection between the two
corresponding stitches of safety airbag alarm lamp No
Rep la ce th e b ulb of a larm la mp.