EC-306
[QR (WITH EURO-OBD)]
DTC P1124, P1126 THROTTLE CONTROL MOTOR RELAY
DTC P1124, P1126 THROTTLE CONTROL MOTOR RELAYPFP:16119
Component DescriptionEBS010RP
Power supply for the throttle control motor is provided to the ECM via throttle control motor relay. The throttle
control motor relay is ON/OFF controlled by the ECM. When the ignition switch is turned ON, the ECM sends
an ON signal to throttle control motor relay and battery voltage is provided to the ECM. When the ignition
switch is turned OFF, the ECM sends an OFF signal to throttle control motor relay and battery voltage is not
provided to the ECM.
CONSULT-II Reference Value in Data Monitor ModeEBS010RQ
Specification data are reference values.
On Board Diagnosis LogicEBS010RR
These self-diagnoses have the one trip detection logic.
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode and the MI lights up.
DTC Confirmation ProcedureEBS010RS
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
PROCEDURE FOR DTC P1124
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 8V.
With CONSULT-II
1. Turn ignition switch ON and wait at least 1 second.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. If DTC is detected, go to EC-311, "
Diagnostic Procedure" .
With GST
Follow the procedure “With CONSULT-II” above.
MONITOR ITEM CONDITION SPECIFICATION
THRTL RELAY
Ignition switch: ON ON
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1124
1124Throttle control motor
relay circuit shortECM detect the throttle control motor relay
is stuck ON.
Harness or connectors
(Throttle control motor relay circuit is shorted.)
Throttle control motor relay
P1126
1126Throttle control motor
relay circuit openECM detects a voltage of power source for
throttle control motor is excessively low.
Harness or connectors
(Throttle control motor relay circuit is open.)
Throttle control motor relay
Engine operating condition in fail-safe mode
ECM stops the electric throttle control actuator control, throttle valve is maintained at a fixed opening (approx. 5 degrees) by the return
spring.
SEF058Y
EC-324
[QR (WITH EURO-OBD)]
DTC P1143 HO2S1
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 35 (HO2S1 signal) and ground.
3. Check one of the following with engine speed held at 2,000 rpm
constant under no load.
The maximum voltage is over 0.6V at least 1 time.
The minimum voltage is over 0.1V at least 1 time.
4. If NG, go to EC-324, "
Diagnostic Procedure" .
Diagnostic ProcedureEBS010S8
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-132, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
MBIB0018E
PBIB2021E
EC-330
[QR (WITH EURO-OBD)]
DTC P1144 HO2S1
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 35 (HO2S1 signal) and ground.
3. Check one of the following with engine speed held at 2,000 rpm
constant under no load.
The maximum voltage is below 0.8V at least 1 time.
The minimum voltage is below 0.35V at least 1 time.
4. If NG, go to EC-330, "
Diagnostic Procedure" .
Diagnostic ProcedureEBS010SG
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-132, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
MBIB0018E
PBIB2021E
EC-336
[QR (WITH EURO-OBD)]
DTC P1146 HO2S2
Procedure for COND2
1. While driving, release accelerator pedal completed with “OD”
OFF (A/T) from the above condition [step 9] until “INCOM-
PLETE” at “COND2” on CONSULT-II screen has turned to
“COMPLETED” (It will take approximately 4 seconds.)
NOTE:
If “COMPLETE” already appears at “COND3” on CONSULT-
II screen before Procedure for COND3 is conducted, it is
unnecessary to conduct step 1 in Procedure for COND3.
Procedure for COND3
1. Stop vehicle and let it idle until “INCOMPLETE” of “COND3” on
CONSULT-II screen has turned to “COMPLETED”. (It will take a
maximum of approximately 6 minutes.)
2. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”.
If “NG” is displayed, refer to EC-338, "
Diagnostic Procedure" .
If “CAN NOT BE DIAGNOSED” is displayed, performed the fol-
lowing.
a. Turn ignition switch OFF and leave the vehicle in a cool place
(soak the vehicle).
b. Turn ignition switch ON and select “COOLAN TEMP/S” in “DATA
MONITOR” mode with CONSULT-II.
c. Start engine and warm it up while monitoring “COOLAN TEMP/S” indication on CONSULT-II.
d. When “COOLAN TEMP/S” indication reaches to 70°C(158°F), go to Procedure for COND1 step 3.
Overall Function CheckEBS010SN
Use this procedure to check the overall function of the heated oxygen sensor 2 circuit. During this check, a 1st
trip DTC might not be confirmed.
WITH GST
1. Start engine and warm it up to the operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Set voltmeter probes between ECM terminal 16 (HO2S2 signal) and ground.
6. Check the voltage when revving up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
The voltage should be below 0.50V at least once during this
procedure.
If the voltage can be confirmed in step 6, step 7 is not nec-
essary.
7. Keep vehicle at idling for 10 minutes, then check the voltage. Or
check the voltage when coasting from 80 km/h (50 MPH) in D
position with “OD” OFF (A/T), 3rd gear position (M/T).
The voltage should be below 0.50V at least once during this
procedure.
8. If NG, go to EC-338, "
Diagnostic Procedure" .
PBIB0556E
SEC775C
MBIB0020E
EC-340
[QR (WITH EURO-OBD)]
DTC P1146 HO2S2
4. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between HO2S2 terminal 2 and ECM terminal 16.
Refer to Wiring Diagram.
2. Check harness continuity between ECM terminal 16 or HO2S2 terminal 2 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 2
Refer to EC-340, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 2.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-124, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionEBS010SQ
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)” as the monitor item with CONSULT-II.Continuity should exist.
Continuity should not exist.
SEF662Y
DTC P1146 HO2S2
EC-341
[QR (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
6. Check “HO2S2 (B1)” at idle speed when adjusting “FUEL INJECTION” to ±25%.
“HO2S2 (B1)” should be above 0.68V at least once when the “FUEL INJECTION” is +25%.
“HO2S2 (B1)” should be below 0.50V at least once when the “FUEL INJECTION” is −25%.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool and approved anti-seize lubricant.
Without CONSULT-II
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Set voltmeter probes between ECM terminal 16 (HO2S2 signal) and ground.
6. Check the voltage when revving up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
The voltage should be above 0.68V at least once during this
procedure.
If the voltage is above 0.68V at step 6, step 7 is not neces-
sary.
7. Keep vehicle at idling for 10 minutes, then check voltage. Or
check the voltage when coasting from 80 km/h (50 MPH) in D
position with “OD” OFF (A/T), 3rd gear position (M/T).
The voltage should be below 0.50V at least once during this
procedure.
8. If NG, replace heated oxygen sensor 2.
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7
in) onto a hard surface such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread
Cleaner tool and approved anti-seize lubricant.
Removal and InstallationEBS010SR
HEATED OXYGEN SENSOR 2
Refer to EX-2, "EXHAUST SYSTEM" .
PBIB0551E
MBIB0020E
EC-344
[QR (WITH EURO-OBD)]
DTC P1147 HO2S2
Procedure for COND2
1. While driving, release accelerator pedal completed with “OD”
OFF (A/T) from the above condition [step 9] until “INCOM-
PLETE” at “COND2” on CONSULT-II screen has turned to
“COMPLETED” (It will take approximately 4 seconds.)
NOTE:
If “COMPLETE” already appears at “COND3” on CONSULT-
II screen before Procedure for COND3 is conducted, it is
unnecessary to conduct step 1 in “Procedure for COND3”.
Procedure for COND3
1. Stop vehicle and let it idle until “INCOMPLETE” of “COND3” on
CONSULT-II screen has turned to “COMPLETED”. (It will take a
maximum of approximately 6 minutes.)
2. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”.
If “NG” is displayed, refer to EC-346, "
Diagnostic Procedure" .
If “CAN NOT BE DIAGNOSED” is displayed, perform the follow-
ing.
a. Turn ignition switch OFF and leave the vehicle in a cool place
(soak the vehicle).
b. Turn ignition switch ON and select “COOLAN TEMP/S” in “DATA
MONITOR” mode with CONSULT-II.
c. Start engine and warm it up while monitoring “COOLAN TEMP/S” indication on CONSULT-II.
d. When “COOLAN TEMP/S” indication reaches to 70°C(158°F), go to Procedure for COND1 step 3.
Overall Function CheckEBS010SW
Use this procedure to check the overall function of the heated oxygen sensor 2 circuit. During this check, a 1st
trip DTC might not be confirmed.
WITH GST
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Set voltmeter probes between ECM terminal 16 (HO2S2 signal) and ground.
6. Check the voltage when revving up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
The voltage should be above 0.68V at least once during this
procedure.
If the voltage can be confirmed in step 6, step 7 is not nec-
essary.
7. Keep vehicle idling for 10 minutes, then check the voltage. Or
check the voltage when coasting from 80 km/h (50 MPH) in D
position with “OD” OFF (A/T), 3rd gear position (M/T).
The voltage should be above 0.68V at least once during this
procedure.
8. If NG, go to EC-346, "
Diagnostic Procedure" .
PBIB0558E
SEC778C
MBIB0020E
EC-348
[QR (WITH EURO-OBD)]
DTC P1147 HO2S2
4. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between HO2S2 terminal 2 and ECM terminal 16.
Refer to Wiring Diagram.
2. Check harness continuity between ECM terminal 16 or HO2S2 terminal 2 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 2
Refer to EC-348, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 2.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-124, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionEBS010SZ
HEATED OXYGEN SENSOR 2
With CONSULT-II
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
4. Let engine idle for 1 minute.
5. Select “FUEL INJECTION” in “ACTIVE TEST” mode, and select
“HO2S2 (B1)” as the monitor item with CONSULT-II.Continuity should exist.
Continuity should not exist.
SEF662Y