Page 493 of 788
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-9
Prior to the wiring harness inspection, check
intermediate connector C-106, joint connector C-35,
junction block connectors C-209 and C-210, and
repair if necessary.
•Check the outside/inside air selection damper
control motor power supply line for open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction P.00-5).
NO : Repair the wiring harness.
STEP 5. Connector check: C-139 A/C-ECU
connector
Q: Is the check result normal?
YES :
Go to Step 6.
YES : Go to Step 7.
NO : Repair the connector.
AC303823
Connectors: C-209, C-210
AE
C-210
Junction block (front view)
C-209
C-209
Harness side
1016
145
12134117 238 9
C-210
Harness side
4 65321
AC303802
Connector: C-139
AE
C-139 (B)
Harness side
AC303818
Connector: C-139
AJ
Harness side
C-139 (B)
11 12657 8 9 103 421
Page 516 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-32
STEP 6. Connector check: C-214 blower relay
connector
Q: Is the check result normal?
YES :
Go to Step 7.
NO : Repair the connector.
STEP 7. Check the blower relay continuity.
Refer to P.55-75.
Q: Is the blower relay continuity in good condition?
YES :
Go to Step 8.
NO : Replace the blower relay.
STEP 8. Voltage measurement at C-214 blower
relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal 3 and
earth.
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 10.
NO : Go to Step 9.
AC303808
Junction block side Junction block (front view)
Connector: C-214
AL
AC303822
Junction block side Junction block (front view)
Connector: C-214
AM
AC303808
Junction block side Junction block (front view)
Connector: C-214
AL
AC303822
Junction block side Junction block (front view)
Connector: C-214
AM
AC301541EI
Connector C-214
(Junction block side)
3
4
5
12
Page 517 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-33
STEP 9. Check the wiring harness between C-214
blower relay connector terminal No.3 and the
ignition switch (IG2).
NOTE: Prior to the wiring harness inspection, check
junction block connector C-210, and repair if
necessary.
•Check the blower relay power supply line for
open circuit.Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction P.00-5).
NO : Repair the wiring harness.
STEP 10. Resistance measurement at C-214
blower relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Measure the resistance Continuity between
terminal 1 and body earth.
OK: 2 ohms or less
Q: Is the check result normal?
YES :
Go to Step 13.
NO : Go to Step 11.
NO : Go to Step 12.
AC303809
Connectors: C-210, C-214
AL
C-214
C-210
Junction block (front view)
C-210 Harness side
Junction block side
C-214
AC303823
Junction block side Junction block (front view)
Connectors: C-210, C-214
C-210C-214 Harness side
C-214
C-210
AK
AC303808
Junction block side Junction block (front view)
Connector: C-214
AL
AC303822
Junction block side Junction block (front view)
Connector: C-214
AM
AC301541EJ
Connector C-214
(Junction block side)
3
4
5
12
Page 518 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-34
STEP 11. Check the wiring harness between
C-214 blower relay connector terminal No.1 and
earth.
NOTE: Prior to the wiring harness inspection, check
junction block connectors C-212, and repair if
necessary.
•Check the blower relay earth wires for open
circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction P.00-5).
NO : Repair the wiring harness.
STEP 12. Check the wiring harness between
C-214 blower relay connector terminal No.1 and
earth.
NOTE:
Prior to the wiring harness inspection, check junction
block connectors C-212 and joint connectors C-07,
and repair if necessary.
•Check the blower relay earth wires for open
circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction P.00-5).
NO : Repair the wiring harness.
AC303809
Junction block (front view)
Connectors: C-212, C-214
C-212C-214
AP
C-212
Harness side
Junction block side
C-214
AC303823
Connectors: C-212, C-214
AO
Junction block (front view)
C-214C-212Junction block side
C-214
C-212
Harness side
AC303814
Connector: C-07
AR
Page 519 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-35
STEP 13. Voltage measurement at C-214 blower
relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Measure the voltage between terminal 5 and
body earth.
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 16.
NO : Go to Step 14.
NO : Go to Step 15.
STEP 14. Check the wiring harness between
C-214 blower relay connector terminal No.5 and
fusible link (1).
NOTE:
Prior to the wiring harness inspection, check
intermediate connectors C-21 and junction block
connector C-211, and repair if necessary.
•Check the blower relay power supply line for
open circuit.
Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction P.00-5).
NO : Repair the wiring harness.
AC303808
Junction block side Junction block (front view)
Connector: C-214
AL
AC303822
Junction block side Junction block (front view)
Connector: C-214
AM
AC301541EK
Connector C-214
(Junction block side)
3
4
5
12
AC303809
Connectors: C-211, C-214
AN
C-214
C-211
Junction block (front view)
C-211 Harness side
Junction block side
C-214
AC303798
Connector: C-21
AK
Page 520 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-36
STEP 15. Check the wiring harness between
C-214 blower relay connector terminal No.5 and
fusible link (1).
NOTE:
Prior to the wiring harness inspection, check
intermediate connectors C-121, C-138 and junction
block connector C-211, and repair if necessary.
•Check the blower relay power supply line for
open circuit.Q: Is the check result normal?
YES :
The trouble can be an intermittent
malfunction (Refer to GROUP 00, How to
Cope with Intermittent Malfunction P.00-5).
NO : Repair the wiring harness.
STEP 16. Connector check: C-140 blower switch
connector
Q: Is the check result normal?
YES :
Go to Step 17.
NO : Repair the connector.
STEP 17. Check the blower switch continuity.
Refer to P.55-79.
Q: Is the blower switch continuity in good condition?
YES :
Go to Step 18.
NO : Replace the blower switch.
AC303823
Connectors: C-211, C-214
AL
C-214
C-211
Junction block (front view)
C-211 Harness side
Junction block side
C-214
AC303816
Connector: C-121
AB
AC303818
Connector: C-138
AI
AC303802
Connector: C-140
AF
Harness side
AC303818
Connector: C-140
AK
Harness side
Page 521 of 788
TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-37
STEP 18. Check the wiring harness between
C-140 blower switch connector terminal No.2 and
C-214 blower relay connector terminal No.4.
NOTE: Prior to the wiring harness inspection, check
junction block connectors C-210, and repair if
necessary.
•Check the blower relay output line for open
circuit.
Q: Is the check result normal?
YES :
Go to Step 19.
NO : Repair the wiring harness.
AC303802
Connector: C-140
AF
Harness side
AC303818
Connector: C-140
AK
Harness side
AC303809
Connectors: C-210, C-214
AL
C-214
C-210
Junction block (front view)
C-210 Harness side
Junction block side
C-214
AC303823
Junction block side Junction block (front view)
Connectors: C-210, C-214
C-210C-214 Harness side
C-214
C-210
AK
Page 529 of 788

TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-45
STEP 4. Connector check: C-213 rear window
defogger relay connector
Q: Is the check result normal?
YES :
Go to Step 5.
NO : Repair the connector.
STEP 5. Check the rear window defogger relay
continuity.
Refer to P.54A-96.
Q: Is the rear window defogger relay continuity in
good condition?
YES :
Go to Step 6.
NO : Replace the rear window defogger relay.
STEP 6. Voltage measurement at C-213 rear
window defogger relay connector.
(1) Remove the relay, and measure at the junction
block side.
(2) Measure the voltage between terminal 5 and
body earth.
OK: System voltage
Q: Is the check result normal?
YES :
Go to Step 9.
NO : Go to Step 7.
NO : Go to Step 8.
AC303808
Junction block side Junction block (front view)
Connector: C-213
AK
AC303822
Junction block side Junction block (front view)
Connector: C-213
AL
AC303808
Junction block side Junction block (front view)
Connector: C-213
AK
AC303822
Junction block side Junction block (front view)
Connector: C-213
AL
AC301541EN
Connector C-213
(Junction block side)
3
4
5
12