Page 130 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-130
.
TECHNICAL DESCRIPTION (COMMENT)
The wiring harness between the door lock actuator or
the ETACS-ECU and the door lock actuator may be
defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The front door lock actuator or rear door lock
actuator may be defective
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tool:
MB991223: Harness Set
STEP 1. Check which door lock is defective.
Q: Which of the door locks is defective?
Driver's door : Go to Step 2.
Front passenger's door : Go to Step 7.
Rear door (LH) : Go to Step 11.
Rear door (RH) : Go to Step 15.
STEP 2. Check front door lock actuator (RH) connector
E-05 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is front door lock actuator (RH) connector E-05 in good
condition?
YES : Go to Step 3.
NO : Repair or check the connector. Refer to GROUP 00E,
Harness Connector Inspection P.00E-2. Verify that all
the doors can be locked and unlocked normally.
Page 142 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-142
INSPECTION PROCEDURE C-3: Central Door Locking System: All the Doors do not Lock or Unlock
with just the Door Lock Switch Operation.
.
TECHNICAL DESCRIPTION (COMMENT)
The door lock switch (incorporated in the power win-
dow main switch and front power window sub switch)
or the ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: diagnostic tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
Check the input signal (by using the pulse check mode of
the monitor).
Check the input signals from the door lock switch (incorporated
in the power window main switch and front power window sub
switch):
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) When the driver's or the front passenger's door lock switch
is moved from "LOCK" to "UNLOCK" and vice versa, check
if diagnostic tool MB991958 sounds or not.
(3) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."
Q: Does diagnostic tool MB991958 sound when the driver's
or the front passenger's door lock switch is moved from
"LOCK" to "UNLOCK" and vice versa?
YES : Replace the ETACS-ECU. Check that all the doors
should be locked and unlocked by the door lock
switch.
NO : Refer to Inspection Procedure N-6 "ETACS-ECU
does not receive any signal from the door lock switch
(incorporated in the power window main switch and
front power window sub switch) P.54B-460."
Page 143 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-143
INSPECTION PROCEDURE C-4: Central Door Locking System: All the Doors do not Lock or Unlock
with just the Door Lock Key Cylinder Key Operation.
.
TECHNICAL DESCRIPTION (COMMENT)
The door lock key cylinder switch or the ETACS-ECU
may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: diagnostic tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
Check the input signal (by using the pulse check mode of
the monitor).
Check the input signals from the door lock key cylinder switch.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) When the doors are locked and unlocked by using the
driver's door lock key cylinder, check that diagnostic tool
MB991958 sounds.
(3) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System Select."
c. Select "SWS."
d. Select "Pulse Checking."
Q: When the doors are locked and unlocked by using the
driver's door lock key cylinder, does diagnostic tool
MB991958 sound?
YES : Replace the ETACS-ECU. Check that all the doors
should be locked and unlocked by using driver door
lock key cylinder switch.
NO : Refer to Inspection Procedure N-4 "ETACS-ECU
does not receive any signal from the door lock key
cylinder switch P.54B-446."
Page 144 of 1500

SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-144
INSPECTION PROCEDURE C-5: Central Door Locking System: Forgotten Key Prevention Function
does not Work Normally.
NOTE: This troubleshooting procedure requires use
of diagnostic tool MB991958 and SWS monitor kit
MB991813. For details on how to use the SWS mon-
itor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU operates the forgotten key preven-
tion function according to the following switches:
Key reminder switch: OFF
Front door switch: ON
Front door lock actuator switch: being turned on
The ETACS-ECU operates the forgotten key preven-
tion function under the following conditions:
Ignition key: inserted into the ignition key cylinder
Front door: open
Front door lock: being locked
.
TECHNICAL DESCRIPTION (COMMENT)
If the function does not work normally, the input cir-
cuit system from the switches or the ETACS-ECU
may be defective (refer to "CIRCUIT OPERATION").
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
Trouble in input signal system
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
Page 148 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-148
POWER WINDOWS
GENERAL DESCRIPTION CONCERNING THE POWER WINDOWSM1549021900244
The following ECUs affect the functions and control
of the power windows.Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
FUNCTION CONTROL ECU
Power window main
switch functionRaises the driver’s power window Power window main switch
Lowers the driver’s power window Power window main switch
Lowers the driver’s power window by one-touch down
functionPower window main switch
Raises the passenger’s power window Power window main switch
Lowers the passenger’s power window Power window main switch
Power window sub
switch functionRaises the passenger’s power window Power window sub switch
Lowers the passenger’s power window Power window sub switch
Power window timer function ETACS-ECU
Page 151 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-151
INSPECTION PROCEDURE D-1: Power Windows: Power windows do not work at all.
NOTE: This troubleshooting procedure requires use
of diagnostic tool MB991958 and SWS monitor kit
MB991813. For details on how to use the SWS mon-
itor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU turns on the power window relay
(installed on the junction block) to activate the power
windows when the ignition switch (IG1) is turned to
the "ON" position.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The power window relay may be defective
The power window main switch may be defective
The ETACS-ECU may be defective
Page 161 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-161
INSPECTION PROCEDURE D-2: Power Window: The power window timer function does not work
normally.
NOTE: This troubleshooting procedure requires use
of diagnostic tool MB991958 and SWS monitor kit
MB991813. For details on how to use the SWS mon-
itor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU operates the power window timer
function according to the following signals:
Ignition switch (IG1)
Front door switch
.
TECHNICAL DESCRIPTION (COMMENT)
If the power window timer function does not work
normally, its input circuit, the ETACS-ECU or the
front-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
Page 164 of 1500
SYMPTOM PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-164
INSPECTION PROCEDURE D-3: Power Window: Only the front door window (RH) does not work by
operating power window main switch.
.
CIRCUIT OPERATION
The front power window regulator motor (RH) lower
or raises the door window (RH) when the power win-
dow main switch is moved to "UP" or "DOWN" posi-
tion.
.
TECHNICAL DESCRIPTION (COMMENT)
The power window main switch or the front power
window regulator motor (RH) may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The power window main switch may be defective
The front power window regulator motor (RH)
may be defective
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
.