Page 408 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-408
INSPECTION PROCEDURE M-2: ETACS-ECU does not receive any signal from the ignition switch
(IG1).
.
CIRCUIT OPERATION
The ETACS-ECU operates the following equipment
or functions according to signal from the ignition
switch (IG1):
Light reminder tone alarm function
Seat belt tone alarm function
Door ajar warning buzzer
Turn-signal lamp buzzer
Multi center display operation tone
multi center display (middle grade type)>
Power window timer function
Sunroof timer function
Headlamp automatic shutdown function
Turn-signal lamp
Dome lamp dimming function
Ignition key hole illumination lamp
If the power supply circuit from the battery to the
ETACS-ECU is open, this circuit is used as
backup circuit.
If the signal is not normal, the equipment or functions
described in "CIRCUIT OPERATION" do not work
normally.
The ETACS-ECU receives information on the ignition
switch condition (IG1) from the combination meter
via CAN communication. If the ignition switch (IG1)
input signal is incorrect, refer to the Diagnostic Trou-
ble Code Chart P.54B-25.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tool:
MB991223: Harness Set
STEP 1. Check ETACS-ECU connector C-219 for loose,
corroded or damaged terminals, or terminals pushed back
in the connector.
Q: Is ETACS-ECU connector C-219 in good condition?
YES : Go to Step 2.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2. If the functions described in "CIRCUIT
OPERATION" work normally, the input signal from the
ignition switch (IG1) should be normal.
Page 409 of 1500
INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-409
STEP 2. Check the ignition switch (IG1) line of the power
supply circuit to the ETACS-ECU. Measure the voltage at
ETACS-ECU connector C-219.
(1) Disconnect ETACS-ECU connector C-219 and measure the
voltage available at the junction block side of the connector.
(2) Turn the ignition switch to the "ON" position.
(3) Measure the voltage between terminal 8 and ground.
The voltage should measure approximately 12 volts
(battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery
positive voltage)?
YES : Replace the ETACS-ECU. If the functions described
in "CIRCUIT OPERATION" work normally, the input
signal from the ignition switch (IG1) should be normal.
NO : Go to Step 3.
STEP 3. Check the wiring harness between ETACS-ECU
connector C-219 (terminal 8) and the ignition switch (IG1).
Page 415 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-415
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
STEP 1. Check the input signal (by using the pulse check
mode of the monitor).
Check the input signals from the front door switches.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958.
(1) Connect the diagnostic tool MB991958.Refer to "How to
connect SWS monitor P.54B-13."
(2) Operate diagnostic tool MB991958 according to the
procedure below to display "Pulse check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "Pulse Checking."
(3) Check that diagnostic tool MB991958 sounds.
Q: Does diagnostic tool MB991958 sound when each front
door is opened and closed?
When the front door (RH) is opened and closed,
diagnostic tool MB991958 does not sound. : Go to Step
2.
When the front door (LH) is opened and closed,
diagnostic tool MB991958 does not sound. : Go to Step
7.
When either front door is opened and closed, diagnostic
tool MB991958 sounds. : Replace the ETACS-ECU. If the
functions described in "CIRCUIT OPERATION" work
normally, the input signal from the front door switches
should be normal.
STEP 2. Check front door switch (RH) connector D-34 for
loose, corroded or damaged terminals, or terminals
pushed back in the connector.
Q: Is front door switch (RH) connector D-34 in good
condition?
YES : Go to Step 3.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2. If the functions described in "CIRCUIT
OPERATION" work normally, the input signal from the
front door switch (RH) should be normal.
Page 420 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-420
INSPECTION PROCEDURE M-5: Column Switch: ETACS-ECU does not receive any signal from the
taillamp switch, the headlamp switch, the passing lamp switch, the dimmer switch or the turn-signal
lamp switch.
NOTE: This troubleshooting procedure requires the
use of diagnostic tool MB991958 and SWS monitor
kit MB991813. For details on how to use the SWS
monitor, refer to "How to connect SWS monitor
P.54B-13."
.
CIRCUIT OPERATION
The ETACS-ECU operates the following equipment
or functions according to signal from the column
switch (turn-signal lamp and lighting switch):
Light reminder tone alarm function
Turn-signal lamp buzzer
Headlamp
Turn-signal lamp
High-beam indicator
Turn-signal indicators
.
TECHNICAL DESCRIPTION (COMMENT)
If the signal is not normal, the equipment or functions
described in "CIRCUIT OPERATION" do not work
normally. If the signal is not normal, the column
switch (turn-signal lamp and lighting switch) or the
ETACS-ECU may be defective.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The column switch (turn-signal lamp and lighting
switch) may be defective
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
MB991223: Harness Set
MB991958: Diagnostic Tool (MUT-III Sub Assembly)
MB991824: Vehicle Communication Interface (V.C.I.)
MB991827: MUT-III USB Cable
MB991910: MUT-III Main Harness A
MB991813: SWS Monitor Kit
MB991806: SWS Monitor Cartridge
MB991812: SWS Monitor Harness (For Column-ECU)
MB991822: Test Probe Harness
Page 421 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-421
STEP 1. Use diagnostic tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the column-ECU.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Operate the diagnostic tool according to the procedure
below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic tool (MUT-III) should show "OK" on the "ECU
COMM Check" menu for the "COLUMN ECU" menu.
Q: Is "OK" displayed for the "COLUMN ECU" menu?
YES : Go to Step 2.
NO : Refer to Inspection Procedure A-2 "Communication
with the column switch (column-ECU) is not possible
P.54B-68."
Page 422 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-422
STEP 2. Check the turn-signal lamp and lighting switch.
Remove the turn-signal lamp and the lighting switch. Then
check continuity between the switch terminals.
Q: Are the turn-signal lamp and lighting switch in good
condition?
YES : Go to Step 3.
NO : Replace the turn-signal lamp and the lighting switch.
The input signal from the column switch (turn-signal
lamp and lighting switch) should be able to be
checked and the functions described in the "CIRCUIT
OPERATION" should work normally.
STEP 3. Replace the column switch.
(1) Replace the column switch.
(2) The input signal from the column switch (turn-signal lamp
and lighting switch) should be able to be checked and the
functions described in the "CIRCUIT OPERATION" should
work normally.
Q: Is the input signal from the column switch (turn-signal
lamp and lighting switch) input normal?
YES : No action is necessary and testing is complete.
NO : Replace the ETACS-ECU. The input signal from the
column switch (turn-signal lamp and lighting switch)
should be able to be checked and the functions
described in the "CIRCUIT OPERATION" should work
normally. SWITCH
POSITIONTESTER
CONNECTIONSPECIFIED
CONDITION
OFF 1
2, 2 3, 2 11,
2
12, 5 9, 7 9Open circuit
Taillight switch 5
9 Less than 2 ohms
Headlamp switch5
9, 7 9 Less than 2 ohms
Passing switch 2
12 Less than 2 ohms
Dimmer switch 2
11, 2 12 Less than 2 ohms
Turn-signal lamp
switch (LH)1
2 Less than 2 ohms
Turn-signal lamp
switch (RH)2
3 Less than 2 ohms
Page 424 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-424
STEP 1. Use diagnostic tool MB991958 to select "ECU
COMM Check" on the SWS monitor display.
Check the column-ECU.
To prevent damage to diagnostic tool MB991958, always
turn the ignition switch to the "LOCK" (OFF) position
before connecting or disconnecting diagnostic tool
MB991958. Connect special tool MB991910 before con-
necting special tool MB991812. Be sure to connect special
tool MB991806 after turning on special tool MB991824.
(1) Connect the special tool. Refer to "How to connect SWS
monitor P.54B-13."
(2) Turn the ignition switch to the "ON" position.
(3) Operate the diagnostic tool according to the procedure
below to display "ECU COMM Check."
a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."
(4) Diagnostic tool (MUT-III) should show "OK" on the "ECU
COMM Check" menu for the "COLUMN ECU" menu.
Q: Is "OK" displayed for the "COLUMN ECU" menu?
YES : Go to Step 2.
NO : Refer to Inspection Procedure A-2 "Communication
with the column switch (column-ECU) is not possible
P.54B-68."
Page 436 of 1500

INPUT SIGNAL PROCEDURES
SIMPLIFIED WIRING SYSTEM (SWS)54B-436
INSPECTION PROCEDURE N-2: ETACS-ECU does not receive any signal from the hazard warning
lamp switch.
.
CIRCUIT OPERATION
The ETACS-ECU operates the following functions or
systems according to signal from the hazard warning
lamp switch:
Turn-signal lamp buzzer
Hazard warning lamp
Keyless entry system (registering the encrypted
code)
.
TECHNICAL DESCRIPTION (COMMENT)
If the signal is not normal, the equipment or systems
described in "CIRCUIT OPERATION" do not work
normally.
.
TROUBLESHOOTING HINTS
Refer to circuit diagrams GROUP-90
Refer to configuration diagrams GROUP-80
The hazard warning lamp switch may be defec-
tive
The wiring harness or connectors may have
loose, corroded, or damaged terminals, or termi-
nals pushed back in the connector
The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tool:
MB991223: Harness Set
STEP 1. Check hazard warning lamp switch connector
C-08 for loose, corroded or damaged terminals, or
terminals pushed back in the connector.
Q: Is hazard warning lamp switch connector C-08 in good
condition?
YES : Go to Step 2.
NO : Repair or replace the damaged component(s). Refer
to GROUP 00E, Harness Connector Inspection
P.00E-2. If the equipment described in "CIRCUIT
OPERATION" work normally, the input signal from the
hazard warning lamp switch should be normal.