LT-114
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: October 20052005 QX56
Terminals and Reference Values for BCMEKS00BAP
Terminal
No.Wire
colorSignal nameMeasuring condition
Reference value
(Approx.) Ignition
switchOperation or condition
2 SB Combination switch input 5 ONLighting, turn, wiper OFF
Wiper dial position 4
3 G/Y Combination switch input 4 ONLighting, turn, wiper OFF
Wiper dial position 4
4 Y Combination switch input 3 ONLighting, turn, wiper OFF
Wiper dial position 4
5 G/B Combination switch input 2
ONLighting, turn, wiper OFF
Wiper dial position 4
6 V Combination switch input 1
32 R/G Combination switch output 5 ONLighting, turn, wiper OFF
Wiper dial position 4
33 R/Y Combination switch output 4 ONLighting, turn, wiper OFF
Wiper dial position 4
34 L Combination switch output 3 ONLighting, turn, wiper OFF
Wiper dial position 4
SKIA5291E
SKIA5292E
SKIA5291E
SKIA5292E
SKIA5291E
SKIA5292E
SKIA5291E
PARKING, LICENSE PLATE AND TAIL LAMPS
LT-115
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: October 20052005 QX56
Terminals and Reference Values for IPDM E/REKS00BAQ
How to Proceed With Trouble DiagnosisEKS00BAR
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 1 0 8 , "
System Description" .
3. Carry out the Preliminary Check. Refer to LT- 11 5 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Do the parking, license and tail lamps operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. Inspection End.
Preliminary CheckEKS00BAS
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES OR FUSIBLE LINK
Check for blown fuses or fusible link.
Refer to LT- 111 , "
Wiring Diagram — TAIL/L —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse or fusible link is blown, be sure to eliminate cause of malfunction before installing new fuse
or fusible link. Refer to PG-4, "
POWER SUPPLY ROUTING CIRCUIT" .
35 O/B Combination switch output 2
ONLighting, turn, wiper OFF
Wiper dial position 4
36 R/W Combination switch output 1
38 W/L Ignition switch (ON) ON — Battery voltage
39 L CAN-H — — —
40 P CAN-L — — —
67 B Ground ON — 0V
70 W/B Battery power supply (fusible link) OFF — Battery voltage Terminal
No.Wire
colorSignal nameMeasuring condition
Reference value
(Approx.) Ignition
switchOperation or condition
SKIA5292E
Terminal
No.Wire
colorSignal nameMeasuring condition
Reference value
(Approx.) Ignition
switchOperation or condition
38 B Ground ON — 0V
39 L CAN-H — — —
40 P CAN-L — — —
57 R/LParking, license, and tail
lampONLighting switch
1ST positionOFF 0V
ON Battery voltage
59 B Ground ON — 0V
Unit Power source Fuse and fusible link No.
BCMBattery f
Ignition switch ON or START position 59
IPDM E/RBattery 53
Battery (Tail lamps ON) 37
PARKING, LICENSE PLATE AND TAIL LAMPS
LT-117
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: October 20052005 QX56
Parking, License Plate and/or Tail Lamps Do Not IlluminateEKS00BAU
1. CHECK COMBINATION SWITCH INPUT SIGNAL
With CONSULT-II
Select "BCM" on CONSULT-II. With "HEAD LAMP" data monitor,
make sure "LIGHT SW 1ST" turns ON-OFF linked with operation of
lighting switch.
Without CONSULT-II
Refer to LT-100, "
Combination Switch Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Check lighting switch. Refer to LT-100, "
Combination
Switch Inspection" .
2. ACTIVE TEST
With CONSULT-II
1. Select "IPDM E/R" on CONSULT-II, and select "ACTIVE TEST"
on "SELECT DIAG MODE" screen.
2. Select "EXTERNAL LAMPS" on "SELECT TEST ITEM" screen.
3. Touch "TAIL" on "ACTIVE TEST" screen.
4. Make sure parking, license plate and tail lamp operation.
Without CONSULT-II
1. Start auto active test. Refer to PG-22, "
Auto Active Test" .
2. Make sure parking, license plate and tail lamp operation.
OK or NG
OK >> GO TO 3.
NG >> GO TO 4.
3. CHECK IPDM E/R
1. Select "IPDM E/R" on CONSULT-II, and select "DATA MONI-
TOR" on "SELECT DIAG MODE" screen.
2. Make sure "TAIL & CLR REQ" turns ON when lighting switch is
in 1ST position.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-28, "Removal and
Installation of IPDM E/R" .
NG >> Replace BCM. Refer to BCS-20, "
Removal and Installa-
tion of BCM" . When lighting switch is in
1ST position: LIGHT SW 1ST ON
SKIA5956E
Parking, license plate and tail lamp should operate
Parking, license plate and tail lamp should operate
WKIA1438E
When lighting switch is in
1ST position: TAIL & CLR REQ ON
SKIA5958E
LT-118
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: October 20052005 QX56
4. CHECK INPUT SIGNAL
With CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect front combination lamp, license plate lamp and rear combination lamp connectors.
3. Turn ignition switch ON.
4. Select "IPDM E/R" on CONSULT-II, and select "ACTIVE TEST" on "SELECT DIAG MODE" screen.
5. Select "TAIL LAMP" on "SELECT TEST ITEM" screen.
6. Touch "ON" on "ACTIVE TEST" screen.
7. When tail lamp is operating, check voltage between front combination lamp, license plate lamp, rear com-
bination lamp harness connector and ground.
Without CONSULT-II
1. Start auto active test. Refer to PG-22, "
Auto Active Test" .
2. When tail lamp is operating, check voltage between front combination lamp, license plate lamp, rear com-
bination lamp harness connector and ground.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
Te r m i n a l s
Vo ltag e Front combination lamp (+)
(–)
ConnectorTe r m i n a l
(Wire color)
RH E107
3 (R/L) Ground Battery voltage
LH E11
WKIA1900E
Te r m i n a l s
Vo ltag e License plate lamps (+)
(–)
ConnectorTe r m i n a l
(Wire color)
D703 + (R/L) Ground Battery voltage
WKIA1076E
Te r m i n a l s
Vo ltag e Rear combination lamp (+)
(–)
ConnectorTe r m i n a l
(Wire color)
RH B130
3 (R/L) Ground Battery voltage
LH B70
WKIA1901E
LT-122
REAR COMBINATION LAMP
Revision: October 20052005 QX56
REAR COMBINATION LAMPPFP:26554
Bulb Replacement (Turn Signal)EKS00BAZ
NOTE:
The tail/stop lamp bulbs are LEDs and are not serviceable separately.
1. Remove rear combination lamp mounting bolts.
2. Pull rear combination lamp to remove from the vehicle.
3. Turn bulb socket counterclockwise and unlock it.
4. Remove bulb.
Installation is in the reverse order of removal.
Removal and InstallationEKS00BB0
1. Remove rear combination lamp mounting bolts.
2. Pull rear combination lamp to remove from the vehicle.
3. Disconnect rear combination lamp connectors.
Installation is in the reverse order of removal.
WKIA1393E
Rear combination lamp
mounting bolts: 2.4 Nm (0.24 kg-m, 21 in-lb)
WKIA1393E
LT-124
TRAILER TOW
Revision: October 20052005 QX56
With the ignition switch in the ON or START position, power is supplied
to ignition relay, located in the IPDM E/R, and
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38, and
through 10A fuse (No. 51, located in the IPDM E/R)
to trailer tow relay 2 terminal 1.
Ground is supplied
to BCM terminal 67, and
to electric brake (pre-wiring) terminal 1
through grounds M57, M61 and M79, and
to IPDM E/R terminals 38 and 59
to trailer tow relay 1 terminal 2
to trailer tow relay 2 terminal 2, and
to trailer connector terminal 2
through grounds E9, E15 and E24.
TRAILER TAIL LAMP OPERATION
The trailer tail lamps are controlled by the trailer tow relay 1.
With the lighting switch in the parking and tail lamp ON (1ST) position, AUTO position (and the auto light sys-
tem is activated) or headlamp ON (2ND) position, power is supplied
through the tail lamp relay, located in the IPDM E/R
through 10A fuse (No. 36, located in the IPDM E/R)
through IPDM E/R terminal 49
to trailer tow relay 1 terminal 1.
When energized, trailer tow relay 1 supplies tail lamp power to trailer connector terminal 6.
TRAILER TURN SIGNAL AND HAZARD LAMP OPERATION
The trailer turn signal and hazard lamps are controlled by the BCM. If either turn signal or the hazard lamps
are turned on, the BCM supplies voltage to the trailer lamps to make them flash.
Left turn signal and hazard lamp output is supplied
through BCM terminal 52
to trailer connector terminal 1.
Right turn signal and hazard lamp output is supplied
through BCM terminal 51
to trailer connector terminal 4.
TRAILER STOP LAMP OPERATION
The trailer stop lamps are controlled by the electric brake. The electric brake receives stop lamp switch signal
when the brake pedal is pressed.
When the brake pedal is pressed, power is supplied
through electric brake (pre-wiring) terminal 3
to trailer connector terminal 3.
TRAILER POWER SUPPLY OPERATION
The trailer power supply is controlled by the trailer tow relay 2.
When the ignition switch is in the ON or START position, power is supplied
through 10A fuse (No. 51, located in the IPDM E/R)
through IPDM E/R terminal 16
to trailer tow relay 2 terminal 1.
When energized, the trailer tow relay 2 supplies power
through trailer tow relay 2 terminals 5 and 7
to trailer connector terminal 5.
LT-130
INTERIOR ROOM LAMP
Revision: October 20052005 QX56
System DescriptionEKS00BB6
When room lamp and personal lamp switch is in DOOR position, room lamp and personal lamp ON/OFF is
controlled by timer according to signals from switches including key switch and key lock solenoid, front door
switch LH, unlock signal from keyfob, door lock and unlock switch, front door lock assembly LH (key cylinder
switch), ignition switch, and glass hatch ajar switch.
When room lamp and personal lamp turns ON, there is a gradual brightening over 1 second. When room lamp
and personal lamp turns OFF, there is a gradual dimming over 1 second.
The room lamp and personal lamp timer is controlled by the BCM (body control module).
Room lamp and personal lamp timer control settings can be changed with CONSULT-II.
Ignition keyhole illumination turns ON when front door LH is opened (door switch ON) or key is removed from
key cylinder. Illumination turns OFF when front door LH is closed (door switch OFF).
Step and foot lamps turn ON when front or rear doors are opened (door switch ON). Lamps turn OFF when
front and rear doors are closed (all door switches OFF).
POWER SUPPLY AND GROUND
Power is supplied at all times
through 10A fuse [No. 19, located in the fuse block (J/B)]
to key switch and key lock solenoid terminal 3, and
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 57, and
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70.
When the key is inserted in key switch and key lock solenoid, power is supplied
through the key switch and key lock solenoid terminal 4
to BCM terminal 37.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38.
Ground is supplied
to BCM terminal 67
through grounds M57, M61 and M79.
When the front door LH is opened, ground is supplied
to BCM terminal 47
through case ground of front door switch LH.
When the front door RH is opened, ground is supplied
to BCM terminal 12
through case ground of front door switch RH.
When the rear door LH is opened, ground is supplied
to BCM terminal 48
through case ground of rear door switch LH.
When the rear door RH is opened, ground is supplied
to BCM terminal 13
through case ground of rear door switch RH.
When the liftgate is opened, ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7
through back door latch (door ajar switch) terminal 8
through grounds B7 and B19.
When the glass hatch is opened, ground is supplied
to BCM terminal 42
through case ground of glass hatch ajar switch.
LT-132
INTERIOR ROOM LAMP
Revision: October 20052005 QX56
through 10A fuse [No. 19, located in the fuse block (J/B)]
to key switch and key lock solenoid terminal 3.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Serial data is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
At the time that front door LH is opened, BCM detects that front door LH is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns the interior room lamps ON for 30 sec-
onds.
Key is in ignition key cylinder (key switch ON), power is supplied
through key switch and key lock solenoid terminal 4
to BCM terminal 37.
When key is removed from key switch and key lock solenoid (key switch OFF), power supply to BCM terminal
37 is terminated. BCM detects that key has been removed, determines that interior room lamp and map lamp
timer conditions are met, and turns the interior room lamps ON for 30 seconds.
When front door LH opens → closes, and the key is not inserted in the key switch and key lock solenoid (key
switch OFF), BCM terminal 47 changes between 0V (door open) → 12V (door closed). The BCM determines
that conditions for interior room lamp operation are met and turns the interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Front door LH is locked [when locked by keyfob, main power window and door lock/unlock switch, or front
door lock assembly LH (key cylinder switch)]
Front door LH is opened (front door switch LH turns ON)
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If interior lamp is left “ON”, it will not be turned off even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
BCM controls interior lamps listed below:
Vanity lamp
Room/map lamp
Cargo lamp
Personal lamp
Step lamps
Puddle lamps
Foot lamps
Ignition keyhole illumination
After lamps turn OFF by the battery saver system, the lamps illuminate again when
signal received from keyfob, or main power window and door lock/unlock switch or front door lock assem-
bly LH (key cylinder switch) is locked or unlocked
door is opened or closed
key is removed from ignition key cylinder (key switch OFF) or inserted in ignition key cylinder (key switch
ON).
Interior lamp battery saver control period can be changed by the function setting of CONSULT-II.