POWER DOOR LOCK SYSTEM
BL-25
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Terminals and Reference Value for BCMEIS008PI
Work FlowEIS008PJ
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to BL-17, "
System Description" .
3. According to the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to BL-29,
"Trouble Diagnoses Symptom Chart" .
4. Does power door lock system operate normally? OK: GO TO 5, NG: GO TO 3.
5. Inspection End.
TerminalWire
ColorItem ConditionVoltage (V)
(Approx.)
12 R/L Front door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
13 GR Rear door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
22 W/V BusWhen ignition switch is ON or power
window timer operates
30 Y/BR Glass hatch switchGlass hatch switch released → Glass
hatch switch pressedBattery voltage → 0
37 B/RKey switch and key lock sole-
noid (insert)Key inserted in IGN key cylinder (ON) →
Key removed from IGN key cylinder
(OFF)Battery voltage → 0
39 L CAN-H — —
40 P CAN-L — —
43 R/BBack door latch (door ajar
switch) Door open (ON) → Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
53 L/W Glass hatch lock actuatorGlass hatch switch released → Glass
hatch switch pressed0 → Battery voltage for 300 msec.
57 Y/R Battery power supply — Battery voltage
59 GFront door lock assembly LH
(actuator) (unlock)Driver door lock knob
(locked → unlocked)0 → Battery voltage
65 V All door lock actuators (lock) Driver door lock knob (neutral → lock) 0 → Battery voltage
66 G/YFront door lock actuator RH,
rear door lock actuators LH/RH
and back door lock actuator
(unlock)Door lock and unlock switch (locked →
unlocked)0 → Battery voltage
67 B Ground — —
70 W/B Battery power supply — Battery voltage
PIIA2344E
POWER DOOR LOCK SYSTEM
BL-33
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Key Switch (Insert) CheckEIS008PO
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.8 - Ground : Continuity should exist.
LIIA0828E
KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
ConnectorTe r m i n a l s
Condition Voltage (V)
(+) (–)
M18 37 GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E
REMOTE KEYLESS ENTRY SYSTEM
BL-53
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Terminals and Reference Value for BCMEIS0 08 Q1
Te r m i n a l Wire
ColorItem ConditionVoltage (V)
(Approx.)
11 O Ignition switch (ACC or ON) Ignition switch (ACC or ON position) Battery voltage
12 R/L Front door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
13 GR Rear door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
18 PRemote keyless entry
receiver ground—0
19 V/WRemote keyless entry
receiver (Power supply)Ignition switch OFF
20 G/WRemote keyless entry
receiver signal (Signal)Stand-by (keyfob buttons released)
When remote keyless entry receiver
receives signal from keyfob (keyfob
buttons pressed)
37 B/RKey switch and key lock sole-
noid (insert)Key inserted in IGN key cylinder (ON)
→ Key removed from IGN key cylinder
(OFF)Battery voltage → 0
38 W/LIgnition switch (ON or
START)Ignition switch (ON or START posi-
tion)Battery voltage
39 L CAN-H — —
40 P CAN-L — —
43 R/BBack door latch (door ajar
switch)Door open (ON) → Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
56 R/GBattery saver
(Interior lamp)Battery saver does operated → Does
not operated (ON → OFF)Battery voltage → 0
57 Y/R Battery power supply — Battery voltage
59 GFront door lock assembly LH
(actuator) (unlock)Door lock & unlock switch
(Neutral → Unlock)0 → Battery voltage
60 G/B Turn signal LHWhen doors are locked or unlocked
using keyfob (OFF → ON) *20 → Battery voltage
61 G/Y Turn signal RHWhen doors are locked or unlocked
using keyfob (OFF → ON) *20 → Battery voltage
62 R/W Step lamp LH and RHStep la mp ON 0
Step lamp OFF Battery voltage
LIIA1893E
LIIA1894E
LIIA1895E
BL-54
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
*1: when room lamp switch is in "DOOR" position.
*2: when hazard reminder is ON.
Terminals and Reference Value for IPDM E/REIS008Q2
*: when horn reminder is ON.63 L Room lampRoom lamp ON *1 Battery voltage
Room Lamp OFF *1 0
65 V All door lock actuators (lock)Door lock & unlock switch
(Neutral → Lock)0 → Battery voltage
66 G/YFront door lock actuator RH,
rear door lock actuators LH/
RH and back door lock actu-
ator (unlock)Door lock & unlock switch
(Neutral → Unlock)0 → Battery voltage
67 B Ground — 0
69 W/RRear power window power
supply— Battery voltage
70 W/B Battery power supply — Battery voltage Terminal Wire
ColorItem ConditionVoltage (V)
(Approx.)
Terminal Wire
ColorItem ConditionVoltage (V)
(Approx.)
38 B Ground — 0
39 L CAN-H — —
40 P CAN-L — —
45 G/W Horn relayWhen doors locks are operated
using keyfob (OFF → ON) *Battery voltage → 0
59 B Ground — 0
REMOTE KEYLESS ENTRY SYSTEM
BL-59
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Trouble Diagnosis ProcedureEIS0 08 Q6
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-45, "
System Description" .
3. Confirm system operation.
Check that the power door lock system operates normally. Refer to BL-16, "POWER DOOR LOCK
SYSTEM" .
Check that the automatic back door system operates normally. Refer to BL-99, "AUTOMATIC BACK
DOOR SYSTEM" .
4. Perform pre-diagnosis inspection. Refer to BL-59, "
BCM Power Supply and Ground Circuit Check" .
5. Refer to trouble diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-60,
"Trouble Diagnoses" .
6. Inspection End.
BCM Power Supply and Ground Circuit CheckEIS0 08 Q7
1. CHECK FUSE AND FUSIBLE LINK
Check the following BCM fuses and fusible link.
NOTE:
Refer to BL-44, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM connectors M18, M20 terminals
11, 38, 57, 70 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Component Parts Terminal No. (SIGNAL) Ampere No. Location
BCM57 (BAT power supply) 15A 22 Fuse block (J/B)
70 (BAT power supply) 50AfFuse and fusible link box
11 (ACC power supply) 10A 4 Fuse block (J/B)
38 (IGN power supply) 10A 59 Fuse and relay box
ConnectorTerminals
Signal nameIgnition
switchVo l ta g e
(+) (–)
M2070
GroundBattery power
supplyOFFBattery
voltage
57Battery power
supplyOFFBattery
voltage
M1811ACC power
supplyACCBattery
voltage
38IGN power
supplyONBattery
voltage
WIIA0600E
BL-60
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
3. CHECK GROUND CIRCUIT
Check continuity between BCM connector M20 terminal 67 and
ground.
OK or NG
OK >> Power supply and ground circuit is OK.
NG >> Repair or replace harness.
Trouble DiagnosesEIS008Q8
SYMPTOM CHART
NOTE:
Always check the "Trouble Diagnosis Procedure" before troubleshooting. Refer to BL-59, "Trouble Diag-
nosis Procedure" .
Always check keyfob battery before replacing keyfob. Refer to BL-65, "Keyfob Battery and Function
Check" .
The panic alarm operation and power back door opener operation of remote keyless entry system do not
activate with the ignition key inserted in the ignition key cylinder.
Use Remote Keyless Entry Tester J-43241 (follow instructions on tester) to check operation of keyfob
before replacing keyfob.
ConnectorTe r m i n a l s
Continuity
(+) (-)
M20 67 Ground Yes
LIIA1040E
Symptom Diagnoses/service procedureReference
page
All functions of remote keyless entry system do not
operate.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Check BCM and keyless receiver.BL-66
The new ID of keyfob cannot be entered.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-652. Key switch and key lock solenoid (insert) checkBL-62
3. Door switch checkBL-63
4. ACC power checkBL-68
5. Replace BCM.BCS-20
Door lock or unlock does not function.
(If the power door lock system does not operate
manually, check power door lock system. Refer to
BL-16, "
POWER DOOR LOCK SYSTEM" )1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Replace BCM.BCS-20
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of keyfob.1. Check hazard and horn reminder mode with CONSULT-II
NOTE:
Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder mode setting.BL-57,
"Active
Te s t"
2. Door switch checkBL-63
3. Replace BCM.BCS-20
REMOTE KEYLESS ENTRY SYSTEM
BL-61
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: October 20052005 QX56
Hazard reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Horn reminder OK)1. Check hazard reminder mode with CONSULT-II
NOTE:
Hazard reminder mode can be changed.
First check the hazard reminder mode setting.BL-57
2. Check hazard function with hazard switch —
3. Replace BCM.BCS-20
Horn reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Hazard reminder OK)1. Check horn reminder mode with CONSULT-II
NOTE:
Horn reminder mode can be changed.
First check the horn reminder mode setting.BL-57
2. Check horn function with horn switch —
3. IPDM E/R operation checkBL-68
4. Replace BCM.BCS-20
Back door open/close operation is not carried out
with keyfob operation.
(The automatic back door system is normal.)1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Key switch (insert) checkBL-62
3. Check that glass hatch is closed —
4. Remote keyless entry receiver systemBL-66
5. Replace BCM.BCS-20
Room lamp, ignition keyhole illumination and step
lamp operation do not activate properly.1. Room lamp operation checkBL-70
2. Ignition keyhole illumination operation checkBL-70
3.Step lamp operation checkLT- 1 3 0
4. Door switch checkBL-63
5. Replace BCM.BCS-20
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.BL-65
2. Key switch and key lock solenoid (insert) checkBL-62
3. Replace BCM.BCS-20
Auto door lock operation does not activate properly.
(All other remote keyless entry functions OK.)1. Check auto door lock operation mode with CONSULT-II
NOTE:
Auto door lock operation mode can be changed.
First check the auto door lock operation mode setting.BL-57
2. Replace BCM.BCS-20
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry functions OK.)1. Check power window down operation mode with CONSULT-II
NOTE:
Power window down operation mode can be changed.
First check the power window down operation mode setting.BL-57
2. Check power window function with switch —
3. Replace BCM.BCS-20
Symptom Diagnoses/service procedureReference
page
BL-62
REMOTE KEYLESS ENTRY SYSTEM
Revision: October 20052005 QX56
Key Switch (Insert) CheckEIS008Q9
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.
2. CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid connector.
3. Check continuity between key switch and key lock solenoid terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch.KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
ConnectorTe r m i n a l s
Condition Voltage (V)
(+) (–)
M18 37 GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E
Terminals Condition Continuity
3 – 4Key is inserted. Yes
Key is removed. No
LIIA1044E