Page 1950 of 4731
DTC P1279, P1289 A/F SENSOR 1 EC-557
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
6. CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect air fuel ratio (A/F) sensor 1 harness connector.
3. Turn ignition switch ON.
4. Check voltage between air fuel ratio (A/F) sensor 1 terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E18, F48
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between air fuel ratio (A/F) sensor 1 and fuse
>> Repair or replace harness or connectors.
Voltage: Battery voltage
PBIB2190E
PBIB1683E
Page 1951 of 4731
![INFINITI FX35 2005 Service Manual EC-558
[VQ35DE]
DTC P1279, P1289 A/F SENSOR 1
Revision: 2005 July 2005 FX
8. CHECK AIR FUEL RATIO (A/F) SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect EC INFINITI FX35 2005 Service Manual EC-558
[VQ35DE]
DTC P1279, P1289 A/F SENSOR 1
Revision: 2005 July 2005 FX
8. CHECK AIR FUEL RATIO (A/F) SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect EC](/manual-img/42/57020/w960_57020-1950.png)
EC-558
[VQ35DE]
DTC P1279, P1289 A/F SENSOR 1
Revision: 2005 July 2005 FX
8. CHECK AIR FUEL RATIO (A/F) SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between the following terminals. Refer to Wiring Diagram.
4. Check harness continuity between the following terminals and ground. Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK AIR FUEL RATIO (A/F) SENSOR 1 HEATER
Refer to EC-412, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace air fuel ratio (A/F) sensor 1.
10. CHECK MASS AIR FLOW SENSOR
Refer to EC-193, "
Component Inspection" .
OK or NG
OK >> GO TO 11.
NG >> Replace mass air flow sensor.
A/F sensor 1 terminal ECM terminal
Bank1 116
275
535
656
Bank 2 176
277
557
658
Continuity should exist.
Bank 1 Bank 2
A/F sensor 1 terminal ECM terminal A/F sensor 1 terminal ECM terminal 116176
275277
535557
656658
Continuity should not exist.
Page 1954 of 4731
![INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation Proced INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation Proced](/manual-img/42/57020/w960_57020-1953.png)
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-561
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
On Board Diagnosis LogicABS006VW
DTC Confirmation ProcedureABS006VX
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41 °F) or more.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CONSULT-II.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSULT-II changes to “COMPLETED”. (It will take approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
564, "Diagnostic Procedure" .
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Select Service $07 with GST.
5. If 1st trip DTC is detected, go to EC-564, "
Diagnostic Procedure" .
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1444
1444 EVAP canister purge
volume control solenoid
valve The canister purge flow is detected during the
specified driving conditions, even when EVAP
canister purge volume control solenoid valve is
completely closed.
EVAP control system pressure sensor
EVAP canister purge volume control
solenoid valve
(The valve is stuck open.)
EVAP canister vent control valve
EVAP canister
Hoses
(Hoses are connected incorrectly or
clogged.)
PBIB0839E
Page 1956 of 4731
![INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-563
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-563
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured](/manual-img/42/57020/w960_57020-1955.png)
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-563
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.) TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
45 GY EVAP canister purge vol-
ume control solenoid valve [Engine is running]
Idle speed
Accelerator pedal is not depressed even
slightly, after engine starting BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Engine speed is about 2,000 rpm (More
than 100 seconds after starting engine) BATTERY VOLTAGE
(11 - 14V)
111 W / B ECM relay
(Self shut-off) [Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF 0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFF BATTERY VOLTAGE
(11 - 14V)
11 9
120 R
R Power supply for ECM
[Ignition switch: ON] BATTERY VOLTAGE
(11 - 14V)
SEC990C
SEC991C
Page 1957 of 4731
![INFINITI FX35 2005 Service Manual EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SU INFINITI FX35 2005 Service Manual EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SU](/manual-img/42/57020/w960_57020-1956.png)
EC-564
[VQ35DE]
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Diagnostic ProcedureABS006VZ
1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between EVAP canister purge volume control solenoid valve terminal 1 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
IPDM E/R harness connector E7
20A fuse
Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIR-
CUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB2006E
Voltage: Battery voltage
PBIB0148E
Continuity should exist.
Page 1958 of 4731
![INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-565
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
INFINITI FX35 2005 Service Manual DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-565
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR](/manual-img/42/57020/w960_57020-1957.png)
DTC P1444 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE EC-565
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
4. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check connectors for water.
OK or NG
OK >> GO TO 5.
NG >> Replace EVAP control system pressure sensor.
5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to EC-358, "
Component Inspection" .
OK or NG
OK (With CONSULT-II)>>GO TO 6.
OK (Without CONSULT-II)>>GO TO 7.
NG >> Replace EVAP control system pressure sensor.
6. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1. Turn ignition switch OFF.
2. Reconnect harness connectors disconnected.
3. Start engine.
4. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to EC-567, "
Component Inspection" .
OK or NG
OK >> GO TO 8.
NG >> Replace EVAP canister purge volume control solenoid valve.
8. CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 9.
NG >> Clean the rubber tube using an air blower.
9. CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to EC-348, "
Component Inspection" .
OK or NG
OK >> GO TO 10.
NG >> Replace EVAP canister vent control valve. Water should not exist.
PBIB1678E
Page 1961 of 4731
![INFINITI FX35 2005 Service Manual EC-568
[VQ35DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
DTC P1446 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionABS006W2
The EVAP canister vent control INFINITI FX35 2005 Service Manual EC-568
[VQ35DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
DTC P1446 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionABS006W2
The EVAP canister vent control](/manual-img/42/57020/w960_57020-1960.png)
EC-568
[VQ35DE]
DTC P1446 EVAP CANISTER VENT CONTROL VALVE
Revision: 2005 July 2005 FX
DTC P1446 EVAP CANISTER VENT CONTROL VALVEPFP:14935
Component DescriptionABS006W2
The EVAP canister vent control valve is located on the EVAP canis-
ter and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is energized.
A plunger will then move to seal the canister vent. The ability to seal
the vent is necessary for the on board diagnosis of other evaporative
emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the evapo-
rative emission control system is depressurized and allows EVAP
Control System diagnosis.
CONSULT-II Reference Value in Data Monitor ModeABS006W3
Specification data are reference values.
On Board Diagnosis LogicABS006W4
PBIB1263E
PBIB1611E
MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/V
Ignition switch: ON OFF
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1446
1446 EVAP canister vent con-
trol valve close EVAP canister vent control valve remains
closed under specified driving conditions.
EVAP canister vent control valve
EVAP control system pressure sensor
and the circuit
Blocked rubber tube to EVAP canister
vent control valve
EVAP canister is saturated with water
Page 1962 of 4731
![INFINITI FX35 2005 Service Manual DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-569
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC Confirmation ProcedureABS006W5
NOTE:
If DTC Confirmation Procedure h INFINITI FX35 2005 Service Manual DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-569
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC Confirmation ProcedureABS006W5
NOTE:
If DTC Confirmation Procedure h](/manual-img/42/57020/w960_57020-1961.png)
DTC P1446 EVAP CANISTER VENT CONTROL VALVE EC-569
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DTC Confirmation ProcedureABS006W5
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON and wait at least 5 seconds.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
4. Start engine and let it idle for at least 1 minute.
5. Repeat next procedures 3 times.
a. Increase the engine speed up to 3,000 to 3,500 rpm and keep it for 2 minutes and 50 seconds to 3 minutes.
Never exceed 3 minutes.
b. Fully released accelerator pedal and keep engine idle for about 5 seconds.
6. If 1st trip DTC is detected, go to EC-571, "
Diagnostic Procedure"
.
If 1st trip DTC is not detected, go to the next step.
7. Repeat next procedure 20 times.
a. Quickly increase the engine speed up to 4,000 to 4,500 rpm or more and keep it for 25 to 30 seconds.
b. Fully released accelerator pedal and keep engine idle for at least 35 seconds.
8. If 1st trip DTC is detected, go to EC-571, "
Diagnostic Procedure" .
WITH GST
Follow the procedure “WITH CONSULT-II” above.
SEF058Y
PBIB0972E