Page 2489 of 4731
EC-1096
[VK45DE]
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR
Revision: 2005 July 2005 FX
2. CHECK CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check sensor harness connector for water.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness connector.
3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.
2. Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B201, M81
Harness connectors M82, F102
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
Water should not exist.
PBIB1522E
Voltage: Approximately 5V
PBIB0138E
Page 2490 of 4731
![INFINITI FX35 2005 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1097
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN INFINITI FX35 2005 Service Manual DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1097
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN](/manual-img/42/57020/w960_57020-2489.png)
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1097
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
5. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND
SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal 67.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B201, M81
Harness connectors M82, F102
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT 1. Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal 2.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> GO TO 8.
8. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B201, M81
Harness connectors M82, F102
Harness for open or short between EVAP control system pressure sensor and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
9. CHECK RUBBER TUBE
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK >> GO TO 10.
NG >> Clean the rubber tube using an air blower, repair or replace rubber tube. Continuity should exist.
Continuity should exist.
Page 2492 of 4731
DTC P0453 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-1099
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Component InspectionABS007OW
EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
2. Install a vacuum pump to EVAP control system pressure sensor.
3. Turn ignition switch ON and check output voltage between ECM terminal 32 and ground under the following conditions.
CAUTION:
Always calibrate the vacuum pump gauge when using it.
Do not apply below -93.3 kPa (-700 mmHg, -27.56 inHg) or
pressure over 101.3 kPa (760 mmHg, 29.92 inHg).
4. If NG, replace EVAP control system pressure sensor.
Applied vacuum kPa (mmHg, inHg) Voltage V
Not applied 1.8 - 4.8
-26.7 (-200, -7.87) 2.1 to 2.5V lower than above value
PBIB1173E
Page 2494 of 4731
![INFINITI FX35 2005 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1101
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation ProcedureAB INFINITI FX35 2005 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1101
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation ProcedureAB](/manual-img/42/57020/w960_57020-2493.png)
DTC P0455 EVAP CONTROL SYSTEM EC-1101
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation ProcedureABS007OY
CAUTION:
Never remove fuel filler cap during the DTC Confirmation Procedure.
NOTE:
Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve
properly.
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait
at least 10 seconds before conducting the next test.
TESTING CONDITION:
Perform “DTC WORK SUPPORT” when the fuel level is between 1/4 and 3/4 full, and vehicle is
placed on flat level surface.
Open engine hood before conducting the following procedures.
WITH CONSULT-II
1. Tighten fuel filler cap securely until ratcheting sound is heard.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
5. Make sure that the following conditions are met. COOLAN TEMP/S: 0 - 70 °C (32 - 158 °F)
INT/A TEMP SE: 0 - 60 °C (32 - 140 °F)
6. Select “EVAP SML LEAK P0442/P1442” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CONSULT-II.
Follow the instruction displayed.
NOTE:
If the engine speed cannot be maintained within the range displayed on the CONSULT-II screen, go to
EC-769, "
Basic Inspection" .
7. Make sure that “OK” is displayed. If “NG” is displayed, select “SELF-DIAG RESULTS” mode and
make sure that “EVAP GROSS LEAK [P0455]” is displayed. If it
is displayed, refer to EC-1102, "
Diagnostic Procedure" .
If P0442 is displayed, perform Diagnostic Procedure for DTC
P0442 EC-1063, "
Diagnostic Procedure" .
PBIB0829E
SEC763C
Page 2495 of 4731
![INFINITI FX35 2005 Service Manual EC-1102
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
WITH GST
NOTE:
Be sure to read the explanation of EC-756, "
Driving Pattern" before driving vehicle.
1. Start engine.
2 INFINITI FX35 2005 Service Manual EC-1102
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
WITH GST
NOTE:
Be sure to read the explanation of EC-756, "
Driving Pattern" before driving vehicle.
1. Start engine.
2](/manual-img/42/57020/w960_57020-2494.png)
EC-1102
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
WITH GST
NOTE:
Be sure to read the explanation of EC-756, "
Driving Pattern" before driving vehicle.
1. Start engine.
2. Drive vehicle according to EC-756, "
Driving Pattern" .
3. Stop vehicle.
4. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
5. Select “Service $07” with GST.
If P0455 is displayed on the screen, go to EC-1102, "Diagnostic Procedure" .
If P0442 is displayed on the screen, go to EC-1063, "Diagnostic Procedure" .
If P0441 is displayed on the screen, go to EC-1058, "Diagnostic Procedure" .
Diagnostic ProcedureABS007OZ
1. CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch OFF.
2. Check for genuine NISSAN fuel filler cap design.
OK or NG
OK >> GO TO 2.
NG >> Replace with genuine NISSAN fuel filler cap.
2. CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened properly by rotating the cap clockwise.
OK or NG
OK >> GO TO 3.
NG >> 1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
2. Retighten until ratcheting sound is heard.
3. CHECK FUEL FILLER CAP FUNCTION
Check for air releasing sound while opening the fuel filler cap.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. CHECK FUEL TANK VACUUM RELIEF VALVE
Refer to EC-733, "
FUEL TANK VACUUM RELIEF VALVE (BUILT INTO FUEL FULLER CAP)" .
OK or NG
OK >> GO TO 5.
NG >> Replace fuel filler cap with a genuine one.
SEF915U
Page 2497 of 4731
EC-1104
[VK45DE]
DTC P0455 EVAP CONTROL SYSTEM
Revision: 2005 July 2005 FX
9. CHECK FOR EVAP LEAK
With CONSULT-II
1. Turn ignition switch ON.
2. Select “EVAP SYSTEM CLOSE” of “WORK SUPPORT” mode with CONSULT-II.
3. Touch “START” and apply pressure into the EVAP line until the pressure indicator reaches the middle of the bar graph.
NOTE:
Do not use compressed air or a high pressure pump.
Do not exceed 4.12 kPa (0.042 kg/cm2 , 0.6 psi) of pres-
sure in the system.
4. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details.
Refer to EC-731, "
EVAPORATIVE EMISSION LINE DRAWING"
.
OK or NG
OK >> GO TO 11.
NG >> Repair or replace.
PEF917U
SEF200U
Page 2498 of 4731
![INFINITI FX35 2005 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1105
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF.
2. Apply INFINITI FX35 2005 Service Manual DTC P0455 EVAP CONTROL SYSTEM EC-1105
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF.
2. Apply](/manual-img/42/57020/w960_57020-2497.png)
DTC P0455 EVAP CONTROL SYSTEM EC-1105
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
10. CHECK FOR EVAP LEAK
Without CONSULT-II
1. Turn ignition switch OFF.
2. Apply 12 volts DC to EVAP canister vent control valve. The valve will close. (Continue to apply 12 volts until the end of test.)
3. Pressurize the EVAP line using pressure pump with 1.3 to 2.7 kPa (10 to 20 mmHg, 0.39 to 0.79 inHg), then remove pump and EVAP service port adapter.
NOTE:
Do not use compressed air or a high pressure pump.
Do not exceed 4.12 kPa (0.042 kg/cm2 , 0.6 psi) of pressure in the system.
4. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details. Refer
to EC-731, "
EVAPORATIVE EMISSION LINE DRAWING" .
OK or NG
OK >> GO TO 12.
NG >> Repair or replace.
11 . CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engine.
3. Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode.
4. Touch “Qu” on CONSULT-II screen to increase “PURG VOL CONT/V” opening to 100%.
5. Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK >> GO TO 14.
NG >> GO TO 13.
PBIB1522E
SEF200U
PBIB0828E
Page 2502 of 4731
![INFINITI FX35 2005 Service Manual DTC P0456 EVAP CONTROL SYSTEM EC-1109
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
CAUTION:
Use only a genuine NISSAN fuel filler cap as a replacement. If an incorrect INFINITI FX35 2005 Service Manual DTC P0456 EVAP CONTROL SYSTEM EC-1109
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
CAUTION:
Use only a genuine NISSAN fuel filler cap as a replacement. If an incorrect](/manual-img/42/57020/w960_57020-2501.png)
DTC P0456 EVAP CONTROL SYSTEM EC-1109
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
CAUTION:
Use only a genuine NISSAN fuel filler cap as a replacement. If an incorrect fuel filler cap is used,
the MIL may come on.
If the fuel filler cap is not tightened properly, the MIL may come on.
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation ProcedureABS007P1
NOTE:
If DTC P0456 is displayed with P0442, first perform trouble diagnosis for DTC P0456.
After repair, make sure that the hoses and clips are installed properly.
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait
at least 10 seconds before conducting the next test.
TESTING CONDITION:
Open engine hood before conducting following procedure.
If any of following conditions are met just before the DTC confirmation procedure, leave the vehi-
cle for more than 1 hour.
–Fuel filler cap is removed.
–Fuel is refilled or drained.
–EVAP component parts is/are removed.
Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-II.
2. Make sure the following conditions are met. FUEL LEVEL SE: 0.25 - 1.4V
COOLAN TEMP/S: 0 - 32 °C (32 - 90 °F)
FUEL T/TMP SE: 0 - 35 °C (32 - 95 °F)
INT A/TEMP SE: More than 0 °C (32 °F)
If NG, turn ignition switch OFF and leave the vehicle in a cool place (soak the vehicle) or refilling/draining
fuel until the output voltage condition of the “FUEL LEVEL SE” meets within the range above and leave
the vehicle for more than 1 hour. Then start from step 1).
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Turn ignition switch ON.
5. Select “EVAP V/S LEAK P0456/P1456” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with CONSULT-II.
Follow the instruction displayed.
6. Make sure that “OK” is displayed. If “NG” is displayed, refer to EC-1111, "
Diagnostic Procedure" .
NOTE:
If the engine speed cannot be maintained within the range displayed on CONSULT-II screen, go
to EC-769, "
Basic Inspection" .
Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid
valve properly.
PBIB0837E