Page 225 of 420
Mode Control
The mode control allows you to
choose from several patterns of air
distribution.
NOTE:To improve your selection choices, the system
allows you to operate at intermediate positions between
the major modes. These intermediate positions are iden-
tified by the small dots.
Panel Mode
Panel Outlets
UNDERSTANDING YOUR INSTRUMENT PANEL 225
4
Page 226 of 420
Air comes from the outlets in the instrument panel. Each
of these outlets can be individually adjusted to direct the
flow of air. Moving the air vane knob on the center
outlets down, will close off the air flow from the center
outlets. The thumbwheel next to the outboard outlets can
be rotated to regulate or shut off the air flow from these
outlets.Bi-Level Mode
Air comes from both the instrument panel outlets, floor
outlets and defrost. A slight amount of air is also directed
through the side window demister outlets.
Bi-Level Outlets
226 UNDERSTANDING YOUR INSTRUMENT PANEL
Page 227 of 420
NOTE:In many temperature lever positions, the bi-
level mode is designed to provide cooler air out of the
panel outlets and warmer air from the floor outlets.
Floor Mode
Air comes from the floor outlets. A slight amount of air is
directed through the defrost and side window demister
outlets.
Mix Mode
Floor OutletsMix Outlets
UNDERSTANDING YOUR INSTRUMENT PANEL 227
4
Page 228 of 420

Air comes from the floor, defrost and side window
demist outlets. This mode works best in cold or snowy
conditions. It allows you to stay comfortable while keep-
ing the windshield clear.
Defrost Mode
Air comes from the windshield and side window demist
outlets. Use this setting when necessary to defrost your
windshield and side windows.
NOTE:For improved safety, the compressor is activated
and the recirculation mode is deactivated when Mix or
Defrost modes are selected. This is done to assist in
drying the air and it will help in keeping the windows
from fogging.
Manual Air Conditioning Operation
To turn on the air conditioning, set the front
blower control to any speed and press the A/C
button which is located next to the recirculation
button. An indicator light on the A/C button shows that
the air conditioning is on.
NOTE:The indicator light in the“POWER”button must
be on for the climate control system to operate.
Defrost Outlets
228 UNDERSTANDING YOUR INSTRUMENT PANEL
Page 229 of 420

Cool dehumidified air comes through the outlets selected
by the Mode Control. To turn off the air conditioning,
press the A/C button a second time. The indicator light
will turn off.
NOTE:
•The compressor will not engage until the engine has
been running for a few seconds.
•If your air conditioning performance seems lower than
expected, check the A/C air filter and the front of the
A/C condenser for an accumulation of dirt or insects.
The A/C condenser is located in front of the radiator.
The A/C air filter is located under the instrument
panel on the passenger side.
•Fabric type fascia protectors tend to block the amount
of air to the condenser and may reduce air condition-
ing performance.
Economy Mode
If economy mode is desired, press the A/C button to turn
off the indicator light, and the A/C compressor. Move the
temperature control lever to the desired temperature.
Recirculation Control
Press the recirculation button to recirculate the
air inside the vehicle. This is located next to the
A/C button. An indicator light on the button
shows that air is being recirculated. Use the
recirculation mode to rapidly cool the inside of the
vehicle. The recirculation mode can also be used to
temporarily block out outside odors, smoke, and dust.
NOTE:
•When the ignition switch is turned OFF, the recircula-
tion feature will be cancelled.
UNDERSTANDING YOUR INSTRUMENT PANEL 229
4
Page 230 of 420

•In cold weather, use of the Recirculation mode may
lead to excessive window fogging. The Recirculation
mode is not allowed in the Mix and Defrost modes to
improve window clearing operation. Recirculation
will be disabled automatically if these modes are
selected.
•If the recirculation button is pressed while in the Mix
or Defrost mode, the indicator light in the recirculation
button will flash 3 times indicating that recirculation is
not allowed.
A/C Recirculation Programming
The recirculation control is programmed to cancel the
recirculation mode when the ignition key is turned OFF
and will reset to outside air mode when the ignition key
is turned ON. The frequent use of outside air will helpkeep odors from building up within the air conditioner-
heater housing. It is recommended that the recirculation
mode be used as little as possible, especially in humid
climates.
For hot and dry climates, or people who are allergic to
pollen and find frequent use of the recirculation mode
necessary, the recirculation mode can be programmed to
not automatically reset to the outside mode by using the
following procedures:
•Turn the ignition switch to the OFF position.
•Set the mode control to“PANEL”.
•Depress and hold in the“POWER”button.
•Start the engine, and continue to hold in the“POWER”
button until the indicator light starts flashing repeat-
edly.
230 UNDERSTANDING YOUR INSTRUMENT PANEL
Page 231 of 420

•Press the recirculation button until the indicator light
remains lit.
•The selection will be stored when the ignition switch is
turned OFF or if the“POWER”button is pressed.
If the recirculation indicator light is lit, the recirculation
mode will not reset when the engine is started. If the
recirculation indicator light is not lit, the recirculation
mode will reset to the outside air mode when the engine
is started. The programmed status can be changed back
and forth by following the above mentioned procedure.
As additional protection against odor build-up in the air
conditioner-heater housing, the recirculation control will
automatically bring in a small amounts of outside air, if
the recirculation feature is on for more than 10 minutes.
You can disable this feature by using one of the following
procedures:1. Pressing the recirculation button twice within two
seconds will temporarily disable this feature. When the
ignition switch is turned OFF, the recirculation mode will
be enabled the next time the ignition switch is turned
ON.
2. You can disable this feature permanently by following
the procedure below:
•Turn the ignition switch to the OFF position.
•Set the mode control to“BI-LEVEL”.
•Depress and hold in the“POWER”button.
•Start the engine, and continue to hold in the
“POWER”button until the indicator light starts
flashing repeatedly.
•Press the recirculation button until the indicator
light remains lit.
UNDERSTANDING YOUR INSTRUMENT PANEL 231
4
Page 232 of 420

•The selection will be stored when the ignition switch
is turned OFF or if the“POWER”button is pressed.
If the recirculation indicator light is lit, the recirculation
mode is enabled. If the recirculation indicator light is not
lit, the recirculation mode is OFF. The programmed status
can be changed back and forth by following the above
mentioned procedure.
Dual-Zone Automatic Temperature Control
The Dual Zone Automatic Temperature Control (ATC)
System automatically maintains the interior comfort level
desired by the driver and front seat passenger. This is
accomplished by using two infrared sensors located in
the center of the instrument panel. The two infrared
sensors independently measure the surface temperature
of the driver and front seat passenger. Based on the
sensor input, the system automatically adjusts the air
temperature, the airflow volume, the airflow distribu-
tion, and amount of inside air recirculation to maintainfront seat occupant comfort, even under changing out-
side weather conditions.
Dual-Zone Automatic Temperature Control
232 UNDERSTANDING YOUR INSTRUMENT PANEL